Baldwin Boxall BV225 Installation Instructions Manual - page 13
BV225 Amplifier
Installation Instructions
BV225 Installation Manual issue 3
7
3 Basic Fault Finding
The BV225 Amplifier front panel provides indicators to show the
current status of the unit. The following sections provide basic
Fault Finding information should these indicators show a fault
condition.
3.1 “P
OWER
” LED
NOT
ILLUMINATED
The Supply LED should be permanently illuminated to show the
24V DC supply is present.
The BV225 Amplifier is protected by an internal 15A automotive
style blade fuse.
If the internal fuse blows when power is applied then it has
suffered an internal fault and should be replaced with a
serviceable unit. The faulty unit should be returned to Baldwin
Boxall for repair.
If the fuse has not blown but the “Supply” LED is not illuminated
then the relevant BVSMP Power Supply should be checked.
C
AUTION
To prevent damage to the unit only replace a blown fuse with the
correct rating and type. Before replacing a blown fuse ensure the
power supply has been disconnected from the unit.