Bananza UHD 150 series Operation Manual - page 53
Manual is about: tubular duct furnace standard range
of
68
SECTION 15: R
EPLACEMENT
P
ARTS
45 of 55
15.2.2 Burner Injectors for Models UHD[T][M][X][S][R] 150-400
Remove 4 screws to remove manifold.
Ensure gas tight fitting of injectors.
Ensure correct alignment with burners.
Ensure all pipe joints are gas tight.
MODEL
UHD
[T][M][X][S][R]
150
UHD
[T][M][X][S][R]
175
UHD
[T][M][X][S][R]
200
UHD
[T][M][X][S][R]
225
UHD
[T][M][X][S][R]
250
UHD
[T][M][X][S][R]
300
UHD
[T][M][X][S][R]
350
UHD
[T][M][X][S][R]
400
Orifice Quantity
7
8
9
10
11
12
14
14
Natural Gas
Orifice Marking
43
43
2.25 mm
2.25 mm
2.25 mm
43
43
40
P/N
91930043
91930043
91930225
91930225
91930225
91930043
91930043
91930040
Propane
Orifice Marking
1.35 mm
1.35 mm
54
54
54
1.45 mm
53
53
P/N
91930135
91930135
91930054
91930054
91930054
91930145
91930053
91930053