    Beo5 type 1682 – 1688, 1692 service manual english german, french, italian, spanish, danish, dutch, japanese and simplified chinese versions are available in the retail system this service manual must be returned with the defective parts/back-up suitcase !.

  • Page 2

    Contents survey of modules ........................................................................................ 1.1 how to service .............................................................................................. 1.2 warnings ............................................................

  • Page 3

    Survey of modules survey of modules 1.1 1 2 3 4 module 1 display module 2 keypad module 3 battery module 4 adaptor, interface.

  • Page 4

    How to service front line service the overall service strategy is to service 95% of all products in the customer’s home. The defective module must be exchanged and the back-up suitcase must be sent to module service in struer. Beo5 will be serviced on module level only as described in the service ma...

  • Page 5

    How to service 1.3 variants of mains adaptors the beo5 has only one variant for all markets. The mains adaptor has separate type nos. For each market, due to country approvals. The only variant on the beo5: 1682 the variants on the mains adaptors: type number variants markets 1683 eu austria, azerba...

  • Page 6

    1.4 warnings warnings esd when electrical replacements or disassembly is taking place, use an esd-mat. The internal electronics are very sensitive to static electricity. The core in the microprocessor is powered with only 1.8 volts, so it is very important that handling of beo5, when disassemblied, ...

  • Page 7

    Service menu service menu in general the menu overview appendix provides an overview of the menus as they appear in the software. The menu items are generally self-explanatory so you can gain a general overview by studying this page closely. For an overview of the menus please refer to page 2.2. Acc...

  • Page 8

    Menu overview 2.2 service menu.

  • Page 9

    Dealer opt dealer option: in this mode it is possible to determine the ir-transmission strength of the beo5. The two options are: - normal mode: all ir transmission will be done according to the configuration. - dealer mode: all ir transmission will only be with low range. The choice is stored in th...

  • Page 10

    2.4.

  • Page 11

    Fault flow chart 3.1 1 2 3 4 5 1 = data - 2 = 5v 3 = charge id 4 = data + 5 = gnd * pin explanation for charger 30 1 p3 1 6 1 3 * pcb keypad fault flow chart no yes confirm the battery is fully charged (2.4v vbat on keypad*, p2 pin 1) ok? Place beo5 in charger. Confirm that ‘charging’ appears on the...

  • Page 12

    30 1 p3 1 6 1 3 * pcb keypad no yes 3.2 fault flow chart confirm that display illuminate when pressing the display area (keys only illuminate in dark environments) ok? Confirm 2.4v vbat on keypad*, p2 pin 1 ok? Place beo5 in charger. Confirm that ‘charging’ appears on the display ok? Replace display...

  • Page 13

    Adjustment back light settings it is possible to determine the time-out period for the back light. There are two back light settings, one for the ‘dimming period’ and one for the ‘off period’. To acces the setting, press ‘standby’ and ‘ok/enter’ simultaneously to invoke ‘setup’ menu, and then press ...

  • Page 14

    4.2.

  • Page 15

    - pull down adaptor, interface - remove screws - gently push down keypad 3x tx5 - remove cables reassembly! Replacement of modules 5.1 replacement of keypad.

  • Page 16

    - remove clips and battery - remove screws for display - remove screws for clips for battery 2x tx5 2x tx6 - remove display by releasing snaplocks 5.2 replacement of modules replacement of display.

  • Page 17

    Specification guidelines for service use 6. Specification guidelines for service use beo5 design david lewis type system terminal (one-hand operated) beo5 – type no. 682 (for all markets) table charger – type no. 683 (eu), 684 (gb), 685 (us), 686 (aus), 687 (kor), * see page .3 (how to service) for ...

  • Page 18

    6.2.

  • Page 19

    Overall block diagram 7.1 cpu mc9328mxs back light converter stld20d 2½” display samsung ltv250qv touch ito layer wheel * charge circuit * step up l6920 64mbit sdram mt48lc2m32b2p-7 flash m29w320eb ir transmiter speaker driver ldo tps73618 usb transceiver a/d converter ad7478a analog switch 74lv4051...

  • Page 20

    7.2 7.2 7.2.

  • Page 21

    > > > > > 30/30pins ffc 0.5mm plug p3 > > 3/3pins 1mm p2 6/6pins 1mm p1 > > keypad p1 plug ffc 0.5mm 30/30pins > > > > > > > display 7.3 wiring diagram 7.3 7.3 wiring diagram wiring diagram.

  • Page 22

    7.4 7.4 7.4.

  • Page 23

    Available parts 9001 9002 9003 9004 9005 9006 9007 9008 1 1 9001 8053177 display,complete 9002 3160426 aluminiumcover 9003 2311013 clipsf/battery 9004 8700091 battery 9005 8003626 keypad 9006 3152499 adaptor,interface 9007 8040141 mainsadaptor,eu 8040142 mainsadaptor,uk 8040143 mainsadaptor,us 80401...

  • Page 24

    8.2.

  • Page 26