Bantam e-STATION BC6 Operating Manual - page 11
+
-
+
-
+
-
+
-
+
-
+
-
BC6
Display
LiPo FAST CHG
2.0A 11.1V(3S)
+
-
+
-
Display
'FAST' charging Lithium battery
'>3 seconds'
You can set up the charging current and the voltage
of the battery pack being charged. As you press
button the voltage confirmation will be displayed. And
then, if you confirm the voltage and current, press
button again to start charging.
This shows the present state of 'FAST' charging. To
stop charging arbitrary, press key once.
Current
voltage of
battery
charge
current
supplied
capacity
elapsed
time
Batt type
Stop
DEC
◀
INC
▶
Start/
Enter
DEC
◀
INC
▶
The charging current is getting smaller as the process goes to the near end term of Lithium
battery charging. To finish charging process earlier, this program eliminate certain term of CV
process. Actually, the charging current will goes to 1/5 from the initial value to end the process
while the normal charging goes to 1/10 during CV term. The charging capacity may be a bit
smaller than normal charging but the process time will be reduced.
This is for charging or discharging Lithium battery not to be used for the time being. The program
will determine to charge or discharge the battery to the certain voltage depending on the voltage of
the battery at its initial stage. They are different from the type of the battery, 3.75V for LiIo, 3.85V
for LiPo and 3.3V for LiFe per cell. If the voltage of battery at its initial stage is over the voltage
level to storage, the program will start to discharge.
You can set up the current and the voltage of the
battery pack to be charged. The current will be used for
charge or discharge the battery to reach the 'storage'
level of voltage.
The screen shows the present situation during charge
process. To stop charging press key once.
Display
+
-
+
-
Display
'>3 seconds'
charge
or
discharge
current
Batt type
Stop
DEC
◀
INC
▶
Start/
Enter
DEC
◀
INC
▶
Start
Enter
Batt type
Stop
'STORAGE' control Lithium battery
Li3S 2.0A 12.59V
FAS 022:43 00682
number
of
cells
Li3S 2.0A 12.59V
STO 022:43 00682
LiPo STORAGE
2.0A 11.1V(3S)
Current
voltage of
battery
supplied
capacity
elapsed
time
number
of
cells
Start
Enter
Batt type
Stop