Bantam e-STATION BC6 Operating Manual - Warning and Error Messages
+
-
+
-
+
-
+
-
+
-
+
-
BC6
Display
REVERSE POLARITY
Display
CONNECTION BREAK
Display
SHORT ERR
Display
INPUT VOL ERR
Display
VOL SELECT ERR
Display
BREAK DOWN
Display
BATTERY CHECK
LOW VOLTAGE
Display
Display
BATTERY VOLTAGE
CELL LOW VOL
Warning and error messages
The output is connected to a battery with incorrect polarity.
This will be displayed in case of detecting an interruption of the
connection between battery and output or voluntarily disconnecting
the charge lead during the operation of charge or discharge on
output.
The voltage of one of the cell in the Lithium battery pack is too low.
Please check the voltage of the cell one by one.
The voltage of Lithium battery pack was selected incorrectly. Verify
the voltage of battery pack carefully.
The processor detects the voltage is lower than you set at Lithium
program. Please check the cell count of the battery pack.
BC6 incorporates a various functions of protective and monitoring the system to verify functions
and the state of its electronics. In any case of occurring error, the screen displays the cause of
error that is self-explanatory with audible sound.
The processor detects the voltage is higher than you set at Lithium
program. Please check the cell count of the battery pack.
Display
There are bad connection at the individual connector. Please check
the connector and cables carefully.
Display
Display
TEMP OVER ERR
Display
CONTROL FAILURE
There was a short-circuit at OUTPUT. Please check the charging
leads.
The voltage of input power drops below the limit.
There happens the malfunction at the charger circuit by any reason.
The charger should be repaired at the factory.
The voltage of one of the cell in the Lithium battery pack is too high.
Please check the voltage of the cell one by one.
The internal temperature of the unit goes too high. Cool down the
unit.
The processor can not continue to control the feeding current by
any reason. The unit needs to be repaired.
BATTERY CHECK
HIGH VOLTAGE
BATTERY VOLTAGE
CELL HIGH VOL
BATTERY VOL ERR
CELL CONNECT