BarcodeYes BLASTER User Manual

Manual is about: BLASTER LINE

Summary of BLASTER

  • Page 1

    - 1 - contents barcode reader blaster line user manual v 4.0 en blaster.

  • Page 2

    - 2 - set up flow chart ........................................2 . Systems information 1.1 set all default .................................................3 1.2 version information .........................................3 . Systems setting 2.1 interfaces ............................................

  • Page 3

    - 3 - barcode scanner install flow chart remark: scan “software version” to get the software version number. Scan “serial number” to get the serial number. Scan the “end” barcode scan the barcode of “start configuration” scan the necessary barcode meet application scan two digits (hex) in the append...

  • Page 4

    - 4 - : systems information 1.1 default 1.2 version information start configuration set all default version end configuration.

  • Page 5

    - 5 - start configuration : systems setting 2.1 interfaces interface selection (keyboard) rs-232 usb end configuration.

  • Page 6

    - 6 - start configuration 2.1.1 keyboard wedge setting terminals type (ibm at) ibm xt ibm ps/2 30-80 ibm 5550 ps/2 25 30 nec 9801 end configuration.

  • Page 7

    - 7 - start configuration languages (us) italian spanish french germany japan end configuration.

  • Page 8

    - 8 - start configuration keyboard terminator none (cr) tab esc function key emulation (off) on keyboard emulation (off) on alt mode (off) on end configuration.

  • Page 9

    - 9 - start configuration caps lock (off) on num lock (off) on inter-character delay 00h 00-64h*1 ms inter-message delay 00h 00-0ah*100 ms keyboard speed 00h 00-08h end configuration.

  • Page 10

    - 10 - start configuration 2.1.2 rs-232 communication parameters baud rate 1200 2400 4800 (9600) 19200 38400 end configuration.

  • Page 11

    - 11 - start configuration data bits 7 (8) data stop 1 2 parity (none) even odd mark space end configuration.

  • Page 12

    - 12 - start configuration inter-character delay 00 -64h*1(ms) inter-message delay 00 -0ah*100(ms) handshaking delay 00 -0ah*100(ms) handshaking (none) rts/cts ack/nak xon/xoff end configuration.

  • Page 13

    - 13 - start configuration character parameter none (cr+lf) cr lf tab stx/etx eot end configuration.

  • Page 14

    - 14 - 2.2 scan mode trigger mode press the trigger and start to scan. The scan will be end once you loose the trigger or decode the barcode. Repeat the action to start the next decodes. Auto power off mode press the trigger and start to scan. The scan will be end once the time is up or decode the b...

  • Page 15

    - 15 - . Timeout set-up 1. Scan the barcode of “continuous/timeout off mode” 2. Scan 2 digits of the ascii code of the appendix a 3. Scan the “end” of the appendix a 4. Scan the end configuration to end the procedure 5. The settings unit is a second. Ex:0*40 stands for 1 minute the timeout default i...

  • Page 16

    - 16 - start configuration scan mode trigger on/off ( trigger on/good read off ) continuous/trigger off testing continuous/led always on continuous/timeout off flash on continuous/no trigger end configuration.

  • Page 17

    - 17 - start configuration 2.3 beep setting buzzer frequency (00-0a-10h) buzzer beep tone (00-05-10h) power up tone (off) on good read beep (off) on end configuration.

  • Page 18

    - 18 - 2.4 character installation the first and last character: you can put 10 ascii at most in front of the barcode data. When the installation is “0” that means you don’t need to add the first and last character. Please find the format as below: the first character barcode the last character the p...

  • Page 19

    - 19 - 3. Scan the “end configuration”. 4. Repeat the same process to the g2 character insertion position. 5. Scan the “end configuration”. Code transmission: if your application needs to transmit the code (barcode type id), you have to set “on” for this feature and the format is id + barcode data..

  • Page 20

    - 20 - start configuration preamble setting (00) postamble setting (00) character insertion g1(00) g2(00) character insertion position g1(00) g2(00) code id transmission on (off) end configuration.

  • Page 21

    - 21 - start configuration 2.5 others setting verify scanning (single) double bar space setting (bar high) bar low laser data scan speed up on off end configuration.

  • Page 22

    - 22 - start configuration 3.1 upc-a reading off (on) code id 46h (20-7eh) upc-a convertor to ean-13 (off) on transmit check char. Off (on) end configuration.

  • Page 23

    - 23 - start configuration upc-a truncate leading zero (off) on truncate leading digit 00h (00-0dh) truncate last digit 00h (00-0dh) select insertion code 00h (00-02h add-on 2/5 (none) 2 5 2/5 end configuration.

  • Page 24

    - 24 - start configuration 3.2 upc-e reading off (on) code id 47h (20-7eh) upc-e convertor to upc-a (off) on transmit check char. Off (on) truncate leading zero (off) on end configuration.

  • Page 25

    - 25 - start configuration upc-e truncate leading digit 00h (00-08h) truncate last digit 00h (00-08h) select insertion code 00h (00-02h) add-on 2/5 (none) 2 5 2/5 end configuration.

  • Page 26

    - 26 - start configuration 3.3 ean-13 reading off (on) code id 48h (20-7eh) transmit check char. Off (on) truncate leading digit 00h (00-0dh) truncate last digit 00h (00-0dh) end configuration.

  • Page 27

    - 27 - start configuration ean-13 add-on 2/5 (none) 2 5 2/5 isbn/issn convert (off) on select insertion code 00h (00-02h) end configuration.

  • Page 28

    - 28 - start configuration 3.4 ean-8 reading off (on) code id 49h (20-7eh) transmit check char. Off (on) truncate leading digit 00h (00-08h) end configuration.

  • Page 29

    - 29 - start configuration ean-8 truncate last digit 00h (00-08h) add-on 2/5 (none) 2 5 2/5 select insertion code 00h (00-02h) end configuration.

  • Page 30

    - 30 - start configuration 3.5 code 39 reading off (on) code id 4ah (20-7eh) verify checksum (off) on transmit check char. Off (on) end configuration.

  • Page 31

    - 31 - start configuration code 39 min. Length 00h (00-32h) max. Length 32h (00-32h) format (standard) full ascii transmit start/end char. (off) on truncate leading digit 00h (00-32h) truncate last digit 00h (00-32h) select insertion code 00h (00-02h) end configuration.

  • Page 32

    - 32 - start configuration 3.6 codabar reading off (on) code id 4bh (20-7eh) verify checksum off (on) transmit check character (off) on end configuration.

  • Page 33

    - 33 - start configuration codabar truncate leading digit 00h (00-7eh) truncate last digit 00h (00-7eh) transmit start/end character (abcd/abcd) abcd/abcd abcd/tn*e transmit start/end character (off) on min. Length 00h (00-3ch) max. Length 3ch (00-3ch) select insertion code 00h (00-02h) end configur...

  • Page 34

    - 34 - start configuration 3.7 code 93 reading off (on) code id 4ch (20-7eh) verify checksum off (on) end configuration.

  • Page 35

    - 35 - start configuration code 93 transmit check character (off) on min. Length 00h (00-50h) max. Length 50h (00-50h) truncate leading digit 00h (00-50h) truncate last digit 50h (00-50h) select insertion code 00h (00-02h) end configuration.

  • Page 36

    - 36 - start configuration 3.8 code 128 end configuration reading off (on) code id 4dh (20-7eh) verify checksum off (on) transmit check character (off) on select insertion code 00h (00-02h).

  • Page 37

    - 37 - start configuration code 128 fnc2 (off) on ucc/ean128 (off) on fnc1 (off) on truncate leading digit 00h (00-7fh) truncate last digit 00h (00-7fh) min. Length 00h (00-7fh) max. Length 7fh (00-7fh) end configuration.

  • Page 38

    - 38 - start configuration 3.9 interleaved 2 of 5 reading off (on) code id 4eh (20-7eh) verify checksum (off) on transmit check character off (on) end configuration.

  • Page 39

    - 39 - start configuration interleaved 2/5 truncate leading digit 00h (00-7eh) truncate last digit 00h (00-7eh) min. Length 00h (00-50h) max. Length 50h (00-50h) select insertion code 00h (00-02h) end configuration.

  • Page 40

    - 40 - start configuration 3.10 industrial 2 of 5 reading (off) on code id 4fh (20-7eh) min. Length 00h (00-32h) max. Length 32h (00-32h) end configuration.

  • Page 41

    - 41 - start configuration industrial 2 of 5 truncate leading digit 00h (00-32h) truncate last digit 00h (00-32h) verify checksum (off) on transmit check character (off) on select insertion code 00h (00-02h) end configuration.

  • Page 42

    - 42 - start configuration 3.11 matrix 2 of 5 reading (off) on code id 50h (20-7eh) verify checksum (off) on end configuration.

  • Page 43

    - 43 - start configuration matrix 2of 5 transmit check character off (on) truncate leading digit 00h (00-50h) truncate last digit 00h (00-50h) min. Length 00h (00-50h) max. Length 50h (00-50h) select insertion code 00h (00-02h) end configuration.

  • Page 44

    - 44 - start configuration 3.12 china post code reading (off) on code id 00h 51(20-7eh) verify checksum (off) on transmit check character (off) on end configuration.

  • Page 45

    - 45 - start configuration china post code truncate leading digit 00h (00-50h) truncate last digit 00h (00-50h) min. Length 00h (00-50h) max. Length 50h (00-50h) select insertion code 00h (00-02h) end configuration.

  • Page 46

    - 46 - start configuration 3.13 msi/plessey reading (off) on code id 52h (20-7eh) verify checksum (off) mod 10 mod 10/10 mod 11/10 end configuration.

  • Page 47

    - 47 - start configuration msi/plessey transmit check character off (on) truncate leading digit 00h (00-3ch) truncate last digit 00h (00-3ch) min. Length 00h (00-3ch) max. Length 3ch (00-3ch) select insertion code 00h (00-02h end configuration.

  • Page 48

    - 48 - start configuration 3.14 code 32 reading (off) on code id 53h (20-7eh) verify checksum off (on) transmit check character off (on) end configuration.

  • Page 49

    - 49 - start configuration code 32 truncate leading digit 00h (00-0ah) truncate last digit 00h (00-0ah) select insertion code 00h (00-02h) end configuration.

  • Page 50

    - 50 - start configuration 3.15 code 11 reading (off) on code id 54h (20-7eh) verify checksum off (on) end configuration.

  • Page 51

    - 51 - start configuration code 11 transmit check character (off) on truncate leading digit 00h (00-50h) truncate last digit 00h (00-50h) min length 00h (00-50h) max. Length 50h (00-50h) select insertion code 00h (00-02h) end configuration.

  • Page 52

    - 52 - appendix a ascii code confirm end configuration.

  • Page 53

    - 53 - ascii table 0 1 2 3 4 5 6 7 0 nul dle sp 0 @ p ` p 1 soh dc1 ! 1 a q a q 2 stx dc2 “ 2 b r b r 3 etx dc3 # 3 c s c s 4 eot dc4 $ 4 d t d t 5 enq nak % 5 e u e u 6 ack syn & 6 f v f v 7 bel etb ‘ 7 g w g w 8 bs can ( 8 h x h x 9 ht em ) 9 i y i y a lf sum * : j z j z b vt esc + ; k [ k { c ff ...

  • Page 54

    - 54 - appendix b function key code table 0 1 0 null 1 up f1 2 down f2 3 left f3 4 right f4 5 page up f5 6 page down f6 7 f7 8 bs f8 9 tab f9 a f10 b home esc c end f11 d enter f12 e insert f delete.

  • Page 55

    - 55 - function key code before scanning barcode, please turn on full ascii code 39 up($a) f1($q) down($b) f2($r) left($c) f3($s) right($d) f4($t) page up($e) f5($u) page down($f) f6($v) f7($w) bs($h) f8($x) tab($i) f9($y) f10($z).

  • Page 56

    - 56 - home($k) esc(%a) end($l) f11(%b) enter($m) f12(%c) insert($n) f13(%d) delete($o) f14(%e).

  • Page 57

    - 57 - installation of your device ps-2 connection rs-232 connection (need 5volts power supply) usb connection.

  • Page 58