- 1 - contents barcode reader blaster line user manual v 4.0 en blaster.
- 2 - set up flow chart ........................................2 . Systems information 1.1 set all default .................................................3 1.2 version information .........................................3 . Systems setting 2.1 interfaces ............................................
- 3 - barcode scanner install flow chart remark: scan “software version” to get the software version number. Scan “serial number” to get the serial number. Scan the “end” barcode scan the barcode of “start configuration” scan the necessary barcode meet application scan two digits (hex) in the append...
- 4 - : systems information 1.1 default 1.2 version information start configuration set all default version end configuration.
- 5 - start configuration : systems setting 2.1 interfaces interface selection (keyboard) rs-232 usb end configuration.
- 6 - start configuration 2.1.1 keyboard wedge setting terminals type (ibm at) ibm xt ibm ps/2 30-80 ibm 5550 ps/2 25 30 nec 9801 end configuration.
- 7 - start configuration languages (us) italian spanish french germany japan end configuration.
- 8 - start configuration keyboard terminator none (cr) tab esc function key emulation (off) on keyboard emulation (off) on alt mode (off) on end configuration.
- 9 - start configuration caps lock (off) on num lock (off) on inter-character delay 00h 00-64h*1 ms inter-message delay 00h 00-0ah*100 ms keyboard speed 00h 00-08h end configuration.
- 10 - start configuration 2.1.2 rs-232 communication parameters baud rate 1200 2400 4800 (9600) 19200 38400 end configuration.
- 11 - start configuration data bits 7 (8) data stop 1 2 parity (none) even odd mark space end configuration.
- 12 - start configuration inter-character delay 00 -64h*1(ms) inter-message delay 00 -0ah*100(ms) handshaking delay 00 -0ah*100(ms) handshaking (none) rts/cts ack/nak xon/xoff end configuration.
- 13 - start configuration character parameter none (cr+lf) cr lf tab stx/etx eot end configuration.
- 14 - 2.2 scan mode trigger mode press the trigger and start to scan. The scan will be end once you loose the trigger or decode the barcode. Repeat the action to start the next decodes. Auto power off mode press the trigger and start to scan. The scan will be end once the time is up or decode the b...
- 15 - . Timeout set-up 1. Scan the barcode of “continuous/timeout off mode” 2. Scan 2 digits of the ascii code of the appendix a 3. Scan the “end” of the appendix a 4. Scan the end configuration to end the procedure 5. The settings unit is a second. Ex:0*40 stands for 1 minute the timeout default i...
- 16 - start configuration scan mode trigger on/off ( trigger on/good read off ) continuous/trigger off testing continuous/led always on continuous/timeout off flash on continuous/no trigger end configuration.
- 17 - start configuration 2.3 beep setting buzzer frequency (00-0a-10h) buzzer beep tone (00-05-10h) power up tone (off) on good read beep (off) on end configuration.
- 18 - 2.4 character installation the first and last character: you can put 10 ascii at most in front of the barcode data. When the installation is “0” that means you don’t need to add the first and last character. Please find the format as below: the first character barcode the last character the p...
- 19 - 3. Scan the “end configuration”. 4. Repeat the same process to the g2 character insertion position. 5. Scan the “end configuration”. Code transmission: if your application needs to transmit the code (barcode type id), you have to set “on” for this feature and the format is id + barcode data..
- 20 - start configuration preamble setting (00) postamble setting (00) character insertion g1(00) g2(00) character insertion position g1(00) g2(00) code id transmission on (off) end configuration.
- 21 - start configuration 2.5 others setting verify scanning (single) double bar space setting (bar high) bar low laser data scan speed up on off end configuration.
- 22 - start configuration 3.1 upc-a reading off (on) code id 46h (20-7eh) upc-a convertor to ean-13 (off) on transmit check char. Off (on) end configuration.
- 23 - start configuration upc-a truncate leading zero (off) on truncate leading digit 00h (00-0dh) truncate last digit 00h (00-0dh) select insertion code 00h (00-02h add-on 2/5 (none) 2 5 2/5 end configuration.
- 24 - start configuration 3.2 upc-e reading off (on) code id 47h (20-7eh) upc-e convertor to upc-a (off) on transmit check char. Off (on) truncate leading zero (off) on end configuration.
- 25 - start configuration upc-e truncate leading digit 00h (00-08h) truncate last digit 00h (00-08h) select insertion code 00h (00-02h) add-on 2/5 (none) 2 5 2/5 end configuration.
- 26 - start configuration 3.3 ean-13 reading off (on) code id 48h (20-7eh) transmit check char. Off (on) truncate leading digit 00h (00-0dh) truncate last digit 00h (00-0dh) end configuration.
- 27 - start configuration ean-13 add-on 2/5 (none) 2 5 2/5 isbn/issn convert (off) on select insertion code 00h (00-02h) end configuration.
- 28 - start configuration 3.4 ean-8 reading off (on) code id 49h (20-7eh) transmit check char. Off (on) truncate leading digit 00h (00-08h) end configuration.
- 29 - start configuration ean-8 truncate last digit 00h (00-08h) add-on 2/5 (none) 2 5 2/5 select insertion code 00h (00-02h) end configuration.
- 30 - start configuration 3.5 code 39 reading off (on) code id 4ah (20-7eh) verify checksum (off) on transmit check char. Off (on) end configuration.
- 31 - start configuration code 39 min. Length 00h (00-32h) max. Length 32h (00-32h) format (standard) full ascii transmit start/end char. (off) on truncate leading digit 00h (00-32h) truncate last digit 00h (00-32h) select insertion code 00h (00-02h) end configuration.
- 32 - start configuration 3.6 codabar reading off (on) code id 4bh (20-7eh) verify checksum off (on) transmit check character (off) on end configuration.
- 33 - start configuration codabar truncate leading digit 00h (00-7eh) truncate last digit 00h (00-7eh) transmit start/end character (abcd/abcd) abcd/abcd abcd/tn*e transmit start/end character (off) on min. Length 00h (00-3ch) max. Length 3ch (00-3ch) select insertion code 00h (00-02h) end configur...
- 34 - start configuration 3.7 code 93 reading off (on) code id 4ch (20-7eh) verify checksum off (on) end configuration.
- 35 - start configuration code 93 transmit check character (off) on min. Length 00h (00-50h) max. Length 50h (00-50h) truncate leading digit 00h (00-50h) truncate last digit 50h (00-50h) select insertion code 00h (00-02h) end configuration.
- 36 - start configuration 3.8 code 128 end configuration reading off (on) code id 4dh (20-7eh) verify checksum off (on) transmit check character (off) on select insertion code 00h (00-02h).
- 37 - start configuration code 128 fnc2 (off) on ucc/ean128 (off) on fnc1 (off) on truncate leading digit 00h (00-7fh) truncate last digit 00h (00-7fh) min. Length 00h (00-7fh) max. Length 7fh (00-7fh) end configuration.
- 38 - start configuration 3.9 interleaved 2 of 5 reading off (on) code id 4eh (20-7eh) verify checksum (off) on transmit check character off (on) end configuration.
- 39 - start configuration interleaved 2/5 truncate leading digit 00h (00-7eh) truncate last digit 00h (00-7eh) min. Length 00h (00-50h) max. Length 50h (00-50h) select insertion code 00h (00-02h) end configuration.
- 40 - start configuration 3.10 industrial 2 of 5 reading (off) on code id 4fh (20-7eh) min. Length 00h (00-32h) max. Length 32h (00-32h) end configuration.
- 41 - start configuration industrial 2 of 5 truncate leading digit 00h (00-32h) truncate last digit 00h (00-32h) verify checksum (off) on transmit check character (off) on select insertion code 00h (00-02h) end configuration.
- 42 - start configuration 3.11 matrix 2 of 5 reading (off) on code id 50h (20-7eh) verify checksum (off) on end configuration.
- 43 - start configuration matrix 2of 5 transmit check character off (on) truncate leading digit 00h (00-50h) truncate last digit 00h (00-50h) min. Length 00h (00-50h) max. Length 50h (00-50h) select insertion code 00h (00-02h) end configuration.
- 44 - start configuration 3.12 china post code reading (off) on code id 00h 51(20-7eh) verify checksum (off) on transmit check character (off) on end configuration.
- 45 - start configuration china post code truncate leading digit 00h (00-50h) truncate last digit 00h (00-50h) min. Length 00h (00-50h) max. Length 50h (00-50h) select insertion code 00h (00-02h) end configuration.
- 46 - start configuration 3.13 msi/plessey reading (off) on code id 52h (20-7eh) verify checksum (off) mod 10 mod 10/10 mod 11/10 end configuration.
- 47 - start configuration msi/plessey transmit check character off (on) truncate leading digit 00h (00-3ch) truncate last digit 00h (00-3ch) min. Length 00h (00-3ch) max. Length 3ch (00-3ch) select insertion code 00h (00-02h end configuration.
- 48 - start configuration 3.14 code 32 reading (off) on code id 53h (20-7eh) verify checksum off (on) transmit check character off (on) end configuration.
- 49 - start configuration code 32 truncate leading digit 00h (00-0ah) truncate last digit 00h (00-0ah) select insertion code 00h (00-02h) end configuration.
- 50 - start configuration 3.15 code 11 reading (off) on code id 54h (20-7eh) verify checksum off (on) end configuration.
- 51 - start configuration code 11 transmit check character (off) on truncate leading digit 00h (00-50h) truncate last digit 00h (00-50h) min length 00h (00-50h) max. Length 50h (00-50h) select insertion code 00h (00-02h) end configuration.
- 52 - appendix a ascii code confirm end configuration.
- 53 - ascii table 0 1 2 3 4 5 6 7 0 nul dle sp 0 @ p ` p 1 soh dc1 ! 1 a q a q 2 stx dc2 “ 2 b r b r 3 etx dc3 # 3 c s c s 4 eot dc4 $ 4 d t d t 5 enq nak % 5 e u e u 6 ack syn & 6 f v f v 7 bel etb ‘ 7 g w g w 8 bs can ( 8 h x h x 9 ht em ) 9 i y i y a lf sum * : j z j z b vt esc + ; k [ k { c ff ...
- 54 - appendix b function key code table 0 1 0 null 1 up f1 2 down f2 3 left f3 4 right f4 5 page up f5 6 page down f6 7 f7 8 bs f8 9 tab f9 a f10 b home esc c end f11 d enter f12 e insert f delete.
- 55 - function key code before scanning barcode, please turn on full ascii code 39 up($a) f1($q) down($b) f2($r) left($c) f3($s) right($d) f4($t) page up($e) f5($u) page down($f) f6($v) f7($w) bs($h) f8($x) tab($i) f9($y) f10($z).
- 56 - home($k) esc(%a) end($l) f11(%b) enter($m) f12(%c) insert($n) f13(%d) delete($o) f14(%e).
- 57 - installation of your device ps-2 connection rs-232 connection (need 5volts power supply) usb connection.
- 58 - http://www.Barcodeyes.Com.