NOTICE
Height and/or piping restriction will reduce the pump output performance.
See the performance chart below to insure you have the proper pump for your application.
Whenever possible use the same size or larger pipe as the pump discharge for optimum
performance. Reducing the pipe size will not harm your pump; it will just reduce the output.
PERFORMANCES
Model #
Output in gallons per minute at listed discharge
height above pumping level
0’
5’
10’
15’
20’
25’
92330
40
34
28
22
12
2
SPECIFICATIONS
Power supply requirements
120V, 60 Hz
Motor
1/3 HP, Continuous Duty,
Split Capacitor
Thermally Protected
Amps
4.1
Liquid Temperature Range
32° F - 120° F (0° C - 49° C)
Circuit Requirements
15 amp minimum
Solids Handling
1/8”
Discharge Size
1 ¼” MIP
Warranty
2 Years
DANGER
Do not use this pump to pump chemicals, flammable liquids, sewage or
corrosive liquids. You could injure yourself and the pump will fail. Pumping these types of
liquids voids the warranty. Barracuda Pump and other pump companies manufacture pumps
for these types of liquids. Make sure you purchase a pump designed for your specific needs.
This pump will handle fluids with the same characteristics as water. If you have any questions
call us at 1-800-495-9278.
WARNING
Your pump has thermal over-load protection built in. It is not recommended for pumping
liquids over 120
F. The thermal overload protector will automatically shut down the pump in
an overheat situation. It will then reset itself once the pump cools down. This overload is
designed as a safety device and it will fail after repeated use. Normal operation is for fluids
between 32
F & 120
F.
DO NOT RUN THE PUMP DRY. The pump depends on water for cooling and lubrication.
Operating the pump without water may cause the motor to overheat or cause damage to parts
of the pump. It may also shorten the life of your pump.
NOTICE
EXTENSION CORDS
For best performance, it is recommended to connect the power cord directly to the grounded
GFCI outlet. If the use of an extension cord is necessary, always use a grounded waterproof
type cord. Never use longer than a 25-ft. cord that is lighter than 14/3 gauge.
DANGER
Keep all electrical connections away from wet and moist environments.
Wet connections can cause electrical shock resulting in personal injury.
USE AND INSTALLATION
WARNING
A
LWAYS DISCONNECT THE POWER SOURCE BEFORE ATTEMPTING TO
INSTALL
,
SERVICE OR PERFORM MAINTENANCE ON THE PUMP
.
FAILURE TO DO SO MAY RESULT IN
FATAL ELECTRICAL SHOCK
.