Basler BE1-27 Manual - page 15
BE1-32R, BE1-32R 0/U
S PECIFICATIONS
(continued)
Sensing
Switch Positions (in Watts)
Input
Nominal
Type
Volts
Range
A
8
c
D
E
F
G
H
J
K
1
Hi
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
A,8,
lo
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
or
2 Hi
20
40
60
80
100
120
140
160
180
200
v
120
lo
5
10
15
20
25
30
35
40
45
50
1
0
3
Hi
100
200
300
400
500
600
700
800
900
1000
lo
25
50
75
100
125
150
175
200
225
250
1
Hi
6.0
12.0
18.0
24.0
30.0
36.0
42.0
48.0
54.0
60.0
C,D,
lo
1.5
3.0
4.5
6.0
7.5
9.0
10.5
12.0
13.5
15.0
or
2 Hi
60
120
180
240
300
360
420
480
540
600
E
120
Lo
15
30
45
60
75
90
105
120
135
150
30
3
Hi
300
600
900
1200
1500
1800 2100
2400
2700
3000
lo
75
150
225
300
375
450
525
600
675
750
4• Hi
4.0
8.0
12.0
16.0
20.0
24.0
28.0
32.0
36.0
40.0
7
lo
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
A, 8,
208
or
5,
Hi
40
80
120
160
200
240
280
320
360
400
v
or
8 lo
240
10
20
30
40
50
60
70
80
90
100
1
0
6, Hi
200
400
600
9
800
1000
1200 1400
1600
1800
2000
lo
50
100
150
200
250
300
350
400
450
500
4,
7
Hi
12.0
24.0
36.0
48.0
60.0
72.0
84.0
96.0
108.0
120.0
lo
3.0
6.0
9.0
12.0
15.0
18.0
21.0
24.0
27.0
30.0
C,D,
208
or
5,
Hi
120
240
360
480
600
720
840
960
1080
1200
E
or
8
240
Lo
30
60
90
120
150
180
210
240
270
300
30
6, Hi
600
1200 1800
2400
3000
3600 4200
4800
5400
6000
9
150
300
450
600
750
900
1050
1200
1350
1500
lo
Table
2
-
Power Range Pickup Settings
Each model, BE1-32R or BE1-32 0/U is capable of
instantaneous trip, definite time delay trip, or an inverse
time delayed trip as defined and selected by the Style
Chart.
Instantaneous response time of the relay is within 80 ms
(60 Hz) or 100 ms (50 Hz) for a real power magnitude of
2 times the setting.
The definite time delay is adjustable over the ranges of
0. 1 to 9.9 seconds and 01 to 99 seconds. Selection of
the ranges is accomplished by a front-panel multiplier
switch which selects either 0.1 or 1.0 as a multiplier of
the front panel Time Dial thumbwheel switch. (A Time
Dial setting of 00 enables instantaneous operation.)
Definite timing accuracy is ±5% of the setting or 50 ms,
whichever is greater.
Inverse time delayed trip is available for the overpower
function only. The inverse time delay curve is adjustable
from 01 to 99 by means of a front-panel thumbwheel
switch. Incrementing the thumbwheel switch moves the
inverse curve along the vertical axis. (See Figure 12 for
Inverse Time Characteristics.) A Time Dial setting of 00
enables instantaneous operation. Inverse time is
accurate to within ±5% of the published curve or
50 ms, whichever is greater.
POWER SUPPLY STATUS OUTPUT
(
OPTIONAL)
The power supply status output relay is energized and
its NC output contact is opened when power is applied
to the relay. Normal internal relay operating voltage
maintains the power supply status output relay continu
ously energized with its output contact open. If the
power supply output voltage falls below the require
ments of proper operation, the power supply output
relay is deenergized, closing the NC output contact.