Basler BE1-27 Manual - page 20
BE1-32R, BE1-320/U
SENSING
TYPE
A) Single-phase
L-N Voltage
B) Single-phase
L-L Voltage
30° phase
shift (60 Hz)
C) Single-phase
Current,
Three-phase
(Open Delta)
Voltage, Scott T
D) Three-phase
Current,
Three-phase
f'Nye) Voltage,
Three Element
E) Two-phase
Current,
Three-phase
(Open Delta)
Voltage, Two
Element
V) Single-phase
L-L Voltage
30° phase shift
(50 Hz)
STYLE N U M BE R I DENTIFICATION C HART
D D D D D D D
D O D
SENSING INPU
.&.
RANGE
1
1) 1 20 Vac, 0.5-20W
(A,B,V) or
1 . 5-60W (C,D,E)
2) 1 20 Vac, 5-200W
(A,B,V) or
1 5-600W (C,D,E)
3) 1 20 Vac,
25-1 000W (A,B,V)
or 75-3000W
(C,D,E)
4) 208 Vac, 1 -40W
(A,B,V) or
3-1 20W (C,D,E)
5) 208 Vac,
1 0-400W (A,B,V)
or 30-1 200W
(C,D,E)
6) 208 Vac,
50-2000W (A,B,V)
or 1 50-6000W
(C,D,E)
7) 240 Vac, 1 -40W
(A,B,V) or
3-1 20W (C,D,E)
8) 240 Vac,
1 0-400W (A,B,V)
or 30-1 200W
(C,D,E)
9) 240 Vac,
50-2000W (A,B,V)
or 1 50-6000W
(C,D,E)
OUTPUT
E) One relay - NO
BE1 -32R only
F) Two relays - NO
BE1 -320/U
G)
One relay - NC
BE1 -32R
H) Two relays - NC
BE1 -320/U
N) Two relays
BE1 -320/U
over - NO
under - NC
P) Two relays
BE1 -320/U
over - NC
under - NO
&
&
POWER
SUPPLY
0)
48 Vdc
P) 1 25 Vdc/
1 20Vac
R) 24 Vdc
T) 250 Vdc/
230 Vac
TIMING
A1) Instantaneous:
one setpoint
BE1 -32R
two setpoints
BE1 -320/U
01) Inverse time:
one adjustment
BE1 -32R
03) Inverse - over
Definite - under
(0.1 -99 sec)
E1) Definite time
(0.1 -99 sec):
one adjustment
BE1 -32R
two adjustments
BE1 -320/U
E2) BE1 -320/U
Under-definite
time (0.1 -99 sec)
over- instanteous
NOTES:
OPTION
1
0) None
OPTION
2
N) None
S) Power supply
status output
TARGET
&.
N) None
A) One internally
operated
target-BE1 -32R
B) One current
operated
target-BE1 -32R
C) Two internally
operated targets,
BE1 -320/U
D) Two current
operated targets,
BE1 -320/U
E) Two targets,
BE1 -320/U
over-internally
operated
under-current
operated
F)
Two targets,
BE1 -320/U
over-current
operated
under-internally
operated
OPTION
4
F) Semi-Flush
Mounting
P) Projection
Mounting
&.
OPTION 3
&
0) None
1) One auxiliary
relay - NO
2) One auxiliary
relay - NC
3) Two auxiliary
relays - NO
BE1 -320/U
4) Two auxiliary
relays - NC
BE1 -320/U
5) One auxiliary
relay - SPOT
7) Two auxiliary
relays,
BE1 -320/U
over - NO
Under - NC
8) Two auxiliary
relays,
BE1 -320/U
over - NC
under - NO
For use with the Sensing Input Type
indicated in parentheses.
Option 3-3,4,5, 7 or 8 may be
Current operated targets may be
selected only when N.O. type
output contacts are selected.
Internally operated targets should
be selected if the breaker control
(trip) circuit is AC powered or the
relay has N.C. type output contacts.
selected only when Option 2 is N.
If model number is BE1 -320/U and
Option 3 is 1 ,2, or 5 the
associated auxiliary relay output
applies to the overpower function only.
Sensing Input Types D and E
require M1 case.