Bissell 1660 User Manual - Troubleshooting
Possible Causes
Remedies
Vacuum is not operating
Check electrical plug
Vacuum/switch on?
Call BISSELL Consumer Services
(see page 14)
Collection tank unit is full
Empty collection tank
Air leak
Check all vacuum connections
Secure all latch buttons
Dirty filter(s)
See PUTTING IT AWAY,
After Dry Vacuuming, Steps 1-2
(see page 9)
Power unit improperly attached
Reposition top power unit on tank unit
Carrying handle in place to lock
tank unit and top power unit?
Kink/blockage in hoses/tubes
Straighten hoses/tubes
Check aluminum wands/vacuum
flex hose/solution hose and tube
for obstructions
Reduced spray or no spray / Leaking connections
Possible Causes
Remedies
Tank siphon tube filter clogged
See PUTTING IT AWAY Steps 9-11
(see page 11)
Filling cavity empty
Refill filling cavity
Spray tip clogged
See PUTTING IT AWAY Step 8
(see page 11)
Tank siphon tube/Solution hose/
Tighten loose connections
Wand solution tube kinked/
Relax kinks in solution tubes/hoses
disconnected
Pump is not operating
Check electrical plug
Pump/spray switch on?
Call BISSELL Consumer Services
( see page 14)
Connections not tight
Finger tighten all connections
(do not use pliers or other tools)
Troubleshooting
Weak or no suction / Motor suddenly runs louder /Motor runs hot.
Reduced spray or no spray / Leaking connections.
12
WARNING:
To reduce the risk
of fire, electric
shock or injury
unplug from outlet
before servicing.