Bullard EDP10 Instruction Manual
Free-Air® Pumps
Instruction Manual
www.bullard.com
TABLE OF CONTENTS
GENERAL INFORMATION ............................................................................... 1
WARNINGS ...................................................................................................... 2
BREATHING AIR REQUIREMENTS ................................................................. 2
ASSEMBLING THE FREE-AIR PUMP
Model EDP10 ................................................................................ 3
Model EDP16TE ............................................................................ 3
Model EDP16HAZ .......................................................................... 3
Pump Performance Specifications ............................................... 3
Electric Motor Specifications ....................................................... 4
OPERATING THE FREE-AIR
®
PUMP ............................................................. 5,6
MAINTAINING THE FREE-AIR PUMP .............................................................. 7
FREE-AIR PUMP TROUBLE SHOOTING GUIDE ............................................ 7,8
REPLACEMENT PARTS .................................................................................... 9
PUMP WARRANTY ........................................................................................ 10
AIR FILTER REPLACEMENT SCHEDULE ....................................................... 11
GENERAL INFORMATION
Bullard Free-Air
®
pumps transfer ambient air from a clean air location, where
breathable air can be assured at all times, to workers wearing Type C or CE
continuous- flow supplied-air respirator hoods or tight fitting half or full face
masks.
The ambient air is filtered through a medium efficiency inlet air filter and a
Carbofine outlet filter before entering the respirator’s air supply hose.
Bullard Free-Air pumps are oil-less and have rotary carbon vanes. They pro-
duce no carbon monoxide, oil vapors, oil mist or moisture. They do not require
expensive carbon monoxide monitors, high temperature alarms or airline
filters. No calibration is required.
The pumps will supply air to one, two or three workers depending on the
pump model and style of respirator(s) being used. The chart below describes
the pump model, the number of respirators each unit will supply and its
maximum outlet pressure.
PUMP SPECIFICATION TABLE
Maximum Number of Respirators
Pump Model No. Hood Style
Full or Half-
Mask
Maximum Outlet
Air Pressure*
EDP10/
EDP1050HZ220V
One
Two
15 psig (103
kPa)**
EDP16TE/
EDP16TEW
Two
Three
15 psig (103
kPa)
EDP16HAZ
Two
Three
15 psig (103
kPa)
* USE ONLY SUPPLIED-AIR RESPIRATORS THAT ARE APPROVED BY MSHA/
NIOSH TO OPERATE AT LESS THAN 15 PSIG (103 kPa).
**To convert kPa to bar, divide kPa by 100
EDP16TE/
EDP16TEW
EDP10
EDP16HAZ
This Manual provides detailed instructions, warnings and other
information for individuals using Bullard Free-Air Pump models
EDP10, EDP1050HZ220V, EDP16TE, EDP16TEW, and EDP16HAZ
EDP1050HZ220V