Bullard EDP10 Instruction Manual - Www.Bullard.Com
www.bullard.com
4
Electric Motor Specifications
Pump Performance Specifications:
EDP10
EDP1050HZ220V
EDP16TE
EDP16HAZ
PUMP DESIGN:
Rotary Carbon Vane (4 vanes)
Rotary Carbon Vane (4 vanes)
Rotary Carbon Vane (4 vanes)
Rotary Carbon Vane (4 vanes)
MAXIMUM PRESSURE:
15 psig (103 kPa)
15 psig (103 kPa)
15 psig (103 kPa)
15 psig (103 kPa)
TOTAL AIR FLOW:
10 cfm @ 5 psig (283 lpm @ 34 kPa) 10 cfm @ 5 psig (283 lpm @ 34 kPa)
16 cfm @ 5 psig (453 lpm @ 34 kPa)
16 cfm @ 5 psig (453 lpm @ 34 kPa)
INLET FILTER:
Medium Efficiency
Medium Efficiency
Medium Efficiency
Medium Efficiency
OUTLET FILTER:
Carbofine with activated carbon
Carbofine with activated carbon
Carbofine with activated carbon
Carbofine with activated carbon
DIMENSIONS:
Width:
8 inches (20.3 cm)
8 inches (20.3 cm)
14 inches (35.5 cm)
14 inches (35.5 cm)
Length:
16.3 inches (41.4 cm)
16.3 inches (41.4 cm)
28 inches (71.1 cm)
28 inches (71.1 cm)
Height:
13.5 inches (34.3 cm)
13.5 inches (34.3 cm)
16 inches (40.6 cm)
16 inches (40.6 cm)
WEIGHT:
49 lbs. (approx.)
(22.2 kg)
49 lbs. (approx.)
(22.2 kg)
98 lbs (approx.)
(44.5 kg)
98 lbs (approx.)
(44.5 kg)
Electric Motor Specifications:
EDP10
EDP1050HZ220V
EDP16TE
EDP16HAZ
ENCLOSURE:
Open, Drip-proof
Meets UL Requirements
CSA Approved
Open, Drip-proof
Meets UL Requirements
CSA Approved
Totally-Enclosed, Fan Cooled Capacitor
Start
Meets UL Requirements,
CSA Approved
Hazardous Duty
Meets UL Requirements, CSA Approved
CLASS:
Natl. Elec. Code:
Class B
Design N
Code K
Natl. Elec. Code:
Class B
Design N
Code K
Natl. Elec. Code:
Class III
Division 1 and 2
National Electric Code:
Class I, Group D, Div. 1 & 2
Class II, Group F, Div. 1 & 2
Class III, Division 1 & 2
H.P.
3/4
1
1 1/2
1 1/2
PHASE:
Single
Single
Single
Three
CYCLES:
60 Hz
50 Hz
60 Hz
60 Hz
VOLTS:
115
220
115/208/230 (Connected for 115 V.)
230 - 460
AMPS:
10.2 @ 115 V.
10.0 @ 220 V.
17.2 @ 115 V.
8.8 @ 208/230 V.
5.0 @ 230 V.
2.5 @ 460 V.
SERVICE FACTOR:
1.25
1.0
1.15
1.0
PROTECTOR:
Internal Thermal Overload
Internal Thermal Overload
Manual Reset Thermal Overload
equipped for 115 volt operation.
Thermal Overload and Starter/
Contactor to beprovided by the user if
rewired to 208/230 volts.
Thermal Overload and Starter/
Contactor to be provided by the user.
WARNING
PROPER MOTOR SELECTION AND WIRING (IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRIC CODES) IS THE RESPONSIBILITY OF THE USER.