Bullerjan O series Operating Manual - page 2
Version: 10/ 2014 - We reserve the right to make changes
Operating manual and certificate of authenticy
for Bullerjan stoves Series O
Please note that all fireplaces, whether a new installation or retrofit, must be approved by a chimney sweep and/or insurance
underwriter. Contact them for specific details.
This stove is an intermittent burning appliance.
Before installing your stove, ensure that the load carrying capacity of the installation location is sufficent for the weight of the
stove including the base and combustion wood. If necessary, there must be weight adustment using a shim.
The Bullerjan GmbH points out that it is not permitted to burn waste, combustible fluids or non-suitable fuels to heat the stove.
1.
Set-up/ Connections/ Installation
1.1
General operation of Bullerjan O stoves
When installing Bullerjan
stoves O and when connecting them to exhaust gas systems, the relevant regluations under public law,
particularly the provisions of state construction ordinances and the approved firing regulations are to be followed.
1.2
Combustion air supply
1
The room in which the stove is to be installed should at least have a minimum volume of 4 m
3
per kW of nomimal heating
capacity.
The air supply for Bullerjan
stoves O, Type 00, 01 and 02 will be sufficient if the room, where the stove is located is provided by
at least one door leading into the open air an by a window which can be opened.
1.3
Connecting pipes
In order to provide maximum echaust gas efficiency for the best stove operations, the stove needs to be connected to the chimney
in the shortest and straightest possible manner. Additonally, this connection should be able to be dismantled for cleaning and
inspection from time to time.
1.4
Safety distance to combustible components and furniture
1
Please note the following table for deviating minimum distances to combustible components and furniture:
Model O
Front
Sides
Back/rear
Floor
Type 00
800 mm
400 mm
650 mm
0
Type 01
800 mm
400 mm
850 mm
0
Type 02
800 mm
400 mm
850 mm
0
1.5
Chimney
Bullerjan
stoves O need a chimney of their own. For the purpose of fire protection, the design of the chimney will be made
according to the EN 13384 using the triple of values indicated in the table below.
The safe operation and the rated thermal output of our Bullerjan
stoves can only be guaranteed if the design of the chimney
with regard to fire protection has been proven to be calculated according o the EN 13384 and confirmed by an authorised chimney
sweep.
Triple of values
Bullerjan –Type „O“
Unit
00
01
02
Nominal heat capacity (NWL)
kW
7,7
10,4
16,0
Exhaust gas mass flow relative to NWL
g/s
14,5
12,4
13,3
Average exhaust temperature
°C
378
370
366
Conveyance pressure
Pa
12
12
12
NO
x
–Emission relative to 13 % O
2
mg/m
3
107,3
115,9
103,6
CO-Emission relative to 13 % O
2
Vol.- %
0,218
0,167
0,299
CO-Emission relative to 13 % O
2
mg/m
3
2724
2092
3735
Dust-Emission relative to 13 % O
2
mg/m
3
59,5
35,9
38,3
C
x
H
y
–Emission relative to 13 % O2 (
total C as OGC)
mg/m
3
181,5
118,9
303,2
Efficiency
%
75
74
77
1
The applicability of the above mentionned values will be subject to other rules and requirements indicated in the firing regulations an building regulations
of the individual states.