Bunn My Cafe AP Programming Manual

Summary of My Cafe AP

  • Page 1

    Programming manual bunn-o-matic corporation post office box 3227 springfield, illinois 62708-3227 phone: (217) 529-6601 fax: (217) 529-6644 41170.0001a 05/12 ©2010 bunn-o-matic corporation my café ® ap.

  • Page 2

    Page 2 41170.1 030912 bunn-o-matic commercial product warranty bunn-o-matic corp. (“bunn”) warrants equipment manufactured by it as follows: 1) airpots, thermal carafes, decanters, gpr servers, iced tea/coffee dispensers, mcp/mca pod brewers thermal servers and thermofresh servers (mechanical and di...

  • Page 3

    Page 3 41170.1 050312 contents lockout switch .............................................................................................4 programming switches...............................................................................5 programming .................................................

  • Page 4

    Page 4 adjustments & programming programming lockout switch programming the brewer the programming of the brewer is divided into two levels. Brewing adjustments are in level 1. Service func- tions are accessed in level 2. The following function screens are in order of appearance. Each screen will ha...

  • Page 5

    Page 5 aut opod bre wer main screen program functions hidden switch press until display reads "brew lockout" press/hold to exit program small brew step backwards through screens prevents brewing if the water temperature is less than the "set ready" temperature. To access this function screen press a...

  • Page 6

    Page 6 brew lockout (yes/no) setting to "yes" only allows brewing at or above the "set ready" temp screen. Brew lockout ? No done yes brew oz a: 8.0 (-) done (+) brew meter a: 2 - + brew oz. (large) (1-16) adjust brew volume for "large" button. Brew meter (large) (1-5) simplified pulse brew adjustme...

  • Page 7

    Page 7 you can set this to "double" if you experience certain types of pods that do not reliably eject on single. Number of ejects single double number of pulses per ounce calculated during flow calibration. For reference only. Do not manually adjust! Flow counts / 10 oz (-) 640 (+) calibrate flow m...

  • Page 8

    Page 8 tank heater relay activates the triac on the main control board for the tank heater. On next off test switches allows testing of the membrane switches. Test switches ? No yes air pump activates the air pump motor for the brew tank. Air pump on next off water inlet activates the water inlet va...

  • Page 9

    Page 9 200˚ cal --> 200˚ (-) brewtank (+) insert an accurate thermometer approximately 7-8˝ into tank. Adjust the number on the right with +/- until it matches reading of thermometer. Press the hidden program button. 41170.1 050312 program functions factory defaults no yes autopod brewer version xx....