C&K Systems SYS3316RF Installation Instructions Manual - page 21
21
21
21
21
21
SYS3316RF Installation Manual
The majority of the keypad commands apply equally to the LED and Alpha II keypads. Some keypad commands, however, apply to the
LCD keypad only.
The following Keypad Commands apply to both the LED and Alpha II keypads:
Keypad Operation Command Summary
Keypad Operation Command Summary
Keypad Operation Command Summary
Keypad Operation Command Summary
Keypad Operation Command Summary
Function
Function
Function
Function
Function
Comments
Comments
Comments
Comments
Comments
Keystroke Sequence
Keystroke Sequence
Keystroke Sequence
Keystroke Sequence
Keystroke Sequence
Arm/Disarm
Delays active
[Combination] [#]
Bypass Zone (n)
[n] is zone # 1 - 16; Combo may be
[Combination] [Bypass] [n] [#]
required
Chime On/Off
Combo may be required
[Combination] [*] [5] [#]
Change Combo using
Must be done from User #1
[Master Combo] [*] [0] [#] [User Number] [#]
Master Combo
[New Combo] [#] [New Combo] [#]
Clear Alarm Memory
[*] [1] [#]
Exit Programming
[*] [#]
Fire Alarm
Keypad activated
[F] (Hold for 3 seconds)
Group Bypass and Arm
Arms the system and all zones programmed for
[Combination] [*] [4] [#]
group bypass, CL 30 - 3F, Digit Position (3),
are shunted simultaneously; Combo may be
required (This is also called Home Arming)
(This is also called Home Arming)
(This is also called Home Arming)
(This is also called Home Arming)
(This is also called Home Arming)
Group Bypass and Instant
Same as Group Bypass (above) except system
[Combination] [*] [4] [7] [#] or
Arm
is Instant Armed (Exit Delay operates normally, [Combination] [*] [7] [4] [#]
upon expiration of Exit Delay, all delayed zones
are converted to Instant - No Entry Delay).
Combo may be required
(Also called Instant/Home Arming)
(Also called Instant/Home Arming)
(Also called Instant/Home Arming)
(Also called Instant/Home Arming)
(Also called Instant/Home Arming)
Instant Arm
Arms system and converts delayed zones to
[Combination] [*] [7] [#]
Instant (Exit Delay active, No Entry Delay),
Combo may be required
Keypad Activated RPS
If enabled, CL 0B(3); Combo may be required
[Combination] [*] [0] [2] [#]
Medical Alarm
Keypad activated
[E] (Hold for 3 seconds)
Police/Panic Alarm
Keypad activated
[P] (Hold for 3 seconds)
Reset Aux Power
If resettable devices are connected to
[*] [6] [2] [#]
Terminals 5 and 6
Reset Panel
[Master Combination] [*] [6] [8] [#]
Test - Battery
Use after correcting Low Battery problem
[*] [6] [4] [#]
Test - Bells
Combo may be required
[Combination] [*] [6] [3] [#]
Test - Central Station
Combo may be required
[Combination] [*] [6] [1] [#]
Test - Local Walk Test
[*] [6] [0] [#]
NOTE:
NOTE:
NOTE:
NOTE:
NOTE: For additional information about Combination Command requirements, see page 24 and CL 09 (2).
The following Keypad Commands apply to the Alpha II keypad only:
Function
Function
Function
Function
Function
Comments
Comments
Comments
Comments
Comments
Keystroke Sequence
Keystroke Sequence
Keystroke Sequence
Keystroke Sequence
Keystroke Sequence
Arm Tones Toggle On/Off
[*] [5] [4] [#]
Audible Feedback Toggle
[*] [5] [1] [#]
Backlight Toggle On/Off
[*] [8] [#]
Display Keypad Model
[*] [9] [#]
& Revision Number
Chime Toggle
[*] [5] [3] [#]
Pre-warn Toggle On/Off
[*] [5] [2] [#]
The following Keypad Commands are Installer Only Commands:
Function
Function
Function
Function
Function
Comments
Comments
Comments
Comments
Comments
Keystroke Sequence
Keystroke Sequence
Keystroke Sequence
Keystroke Sequence
Keystroke Sequence
Alpha Keypad Programming
Start Programming the Keypad
[Installer Combination] [*] [0] [1] [#]
Alpha Keypad Test
[*] [6] [7] [#]
Kill/Revive Panel
[Installer Combination] [*] [6] [9] [#]
Panel Programming
Start Programming the Panel
[Installer Combination] [*] [0] [#]