WIRING
Clamp description and purpose :
12V = Positive 12Vcc.
GND = GND ( negative)
AMK = Antimasking Output N.C.
AS = TAMPER (N.C.)
MEM = Inhibition input and alarm memory enabling
(positive)
AL = Alarm output N.C.
LED indicator
LD4 = Red Led (alarm)
LD5 = Yellow Led (microwave)
LD6 = Green Led (IR)
Trimmer
IR Range = IR range adjustment
MW Range = MW range adjustment
DIP Switch SW1
JUMPER JP1
It is possible to set up detector for external or internal use using ’JP1’Jumper ‘’ as described
in the following chart:
DETECTION LENGTH CHART
DIP
1
2
3
4
ON
Antimask
Enabled
AND
IR ANTIMASK
ENABLED
Led
Enabled
OFF
Antimask
Disabled
OR
IR ANTIMASK
DISABLED
Led
Disabled
JP1 plugged in
External use setup: more stability, more power consumption
JP1 plugged out
Internal use setup: more sensitivity, less power consumption