DETECTION OPTIONS
•
Mw antimask
When this function is enabled, AMK output activates if an obstacle remains in
front of detector about 25sec.
•
IR antimask
When this function is enabled, AMK output activates if an obstacle remains in
front of detector. A IR active signal will be checked out to verify this condition.
IMPORTANT NOTICE:
We suggest to do not activate “Mw Antimask” function if detector is installed
outside where it can be exposed to rain, snow etc..
- AND
Detector will be in alarm only if MW and IR are both in pre alarm condition.
- OR
Detector will be in alarm if MW or IR are in pre alarm condition.