CABAC 3031 Manual - 9. Technical Data
Battery Replacement
10
9. Technical data
Voltage range:
12…690V AC (16…400Hz),
DC(±)
LED Nominal voltage: 12/24/50/120/230/400/690V, AC
(16…400Hz),
DC(±)
LED tolerances according to
EN61243-3
ELV indication LED:
>50VAC, >120VDC
Response time:
nominal
voltage
LCD Range:
0…690V, AC (16…400Hz),
DC(±)
LCD Resolution:
0.1V
LCD Accuracy:
±3%±5dgt (0…690V)
LCD Overrange
indication:
“OL”
Peak current:
Is
Measurement Duty:
30s ON (operation time),
240s OFF (recovery time)
Internal battery
consumption:
approx. 80mA
Single-pole phase test
voltage range:
100…690V AC (50/60Hz)
Phase rotation test:
120…400V earth-to-phase,
AC
50/60Hz
Continuity test:
Detection range 0…500kΩ +
50%
Battery:
3V (IEC LR03 1.5V x 2)
Temperature:
-15…55°C operation; -20…70°C
storage, No condensation
Humidity:
Max 85% RH
Altitude:
up to 2000m
Overvoltage:
CAT III/1000V, CAT IV 600V
Standard:
EN61243-3:2010
Pollution:
degree 2
Protection:
IP 64