Cabletron Systems 7F06-02 FDDI SmartSwitch User Manual

Other manuals for 7F06-02 FDDI SmartSwitch: User Manual
Manual is about: Interface Module

Summary of 7F06-02 FDDI SmartSwitch

  • Page 1

    7f06-02 fddi smartswitch ™ interface module user’s guide 9031672-01.

  • Page 2: Notice

    Notice i notice cabletron systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult cabletron systems to determine whether any such changes have been made. The hardware, firmware, or soft...

  • Page 3: Fcc Notice

    Notice ii fcc notice this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Not...

  • Page 4: Vcci Notice

    Notice iii vcci notice this equipment is in the 1st class category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the voluntary control council for interference by information technology equipment (vcci) aimed at preventing radio interfe...

  • Page 5: Contents

    V contents chapter 1 introduction 1.1 using this manual .........................................................................1-1 1.2 the 7f06-02 module...........................................................................1-2 1.2.1 cable type and fpims ..........................................

  • Page 6

    Vi contents 5.7 physical ................................................................................................5-2 5.7.1 dimensions .....................................................................................5-2 5.7.2 weight ...........................................................

  • Page 7: Chapter  1

    1-1 chapter 1 introduction welcome to cabletron systems 7f06-02 fddi smartswitch interface module user’s guide . This guide is a simple reference for installing and using the 7f06-02 module. Before installing this module, you should carefully read through this manual to gain a full understanding of ...

  • Page 8: 1.2  The 7F06-02 Module

    1-2 introduction 1.2 the 7f06-02 module the 7f06-02 module provides two fiber optic ports via front panel fpim modules. 1.2.1 cable type and fpims the 7f06-02 module has two front panel connectors that interface to the 7x00 smart switch module through the chassis backplane. The front panel connectio...

  • Page 9: Smartswitch

    Introduction 1-3 figure 1-1. 7f06-02 module 1.2.2 7c03 mmac smartswitch, the 7c04 workgroup smartswitch and the 7c04-r workgroup smartswitch the 7f06-02 module is designed to be installed in the 7c03 mmac smartswitch, the 7c04 workgroup smartswitch or the 7c04-r workgroup smartswitch. The modular de...

  • Page 10: 1.3  Features

    1-4 introduction token ring to be used with the 7f06-02 module. These modules provide the capability to share data without the use of external bridges or routers. The 7c03 mmac smartswitch is a unique module that can be installed in an mmac series chassis. The 7c04 workgroup smartswitch and the 7c04...

  • Page 11: 1.4  Related Manuals

    Introduction 1-5 1.4 related manuals the manuals listed below should be used to supplement the procedures and other technical data provided in this manual. The procedures will be referenced, where appropriate, but will not be repeated. 7x00 smartswitch control module user’s guide 7f06-02 local manag...

  • Page 12: Chapter  2

    2-1 chapter 2 network requirements before installing cabletron systems 7f06-02 module, review the network requirements outlined in this chapter. All requirements included in this chapter should be met to ensure satisfactory performance of the 7f06-02 module. Failure to do so may result in unsatisfac...

  • Page 13

    2-2 network requirements transmitter power parameters are listed in table 2-2. The link distance is up to 2 kilometers on the multimode fiber- optic cable as specified by ansi mmf-pmd. Table 2-2. Transmitter power parameters parameter typical value worst case worst case budget typical budget 50/125 ...

  • Page 14: 2.1.2  Fpim-02 and Fpim-04

    Network requirements 2-3 2.1.2 fpim-02 and fpim-04 the fpim-02 has an rj-45 connector supporting an unshielded twisted pair (utp) connection. The fpim-04 has an rj-45 connector supporting a shielded twisted pair (stp) connection. The pinouts for both are listed in table 2-3. The link distance is up ...

  • Page 15: 2.1.3  Fpim-05 and Fpim-07

    2-4 network requirements 2.1.3 fpim-05 and fpim-07 the fpim-05 and fpim-07 provide a single-mode fiber connection. The fpim-05 uses a mic style connector and the fpim-07 uses an sc type connector. The specifications for both devices are listed in table 2-4. The link distance is up to 40 kilometers (...

  • Page 16: Chapter  3

    3-1 chapter 3 installation/removal this chapter contains instructions for unpacking and installing the 7f06-2 module in the: • 7c03 mmac smartswitch • 7c04 workgroup smartswitch • 7c04-r workgroup smartswitch. Also included in the chapter are instructions the front panel fpims. 3.1 unpacking the 7f0...

  • Page 17

    3-2 installation/removal figure 3-1. Installing an fpim 3.3 installing/removing the 7f06-02 module the following procedure detail the installing and removal procedure for the 7f06-02 module. 3.3.1 installing in the 7c03 smartswitch the 7f06-02 module is installed in the 7c03 mmac smartswitch using t...

  • Page 18: Notes:

    Installation/removal 3-3 notes: the left most slot in the 7c03 mmac smartswitch is reserved for the 7x00 smartswitch module. Before installing the 7f06-02 module, attach the wrist strap included with the smartswitch or smartswitch module by following the instructions printed on the package. 1. Remov...

  • Page 19: Note:

    3-4 installation/removal note: before removing the 7f06-02 module, attach the wrist strap included with the smartswitch or smartswitch module by following the instructions printed on the package. 1. Use a slotted screwdriver to loosen the two screws that secure the module to the chassis. 2. Locate t...

  • Page 20: Smartswitch

    Installation/removal 3-5 3.3.3 installing in the 7c04 or 7c04-r workgroup smartswitch the 7f06-02 module is installed in the 7c04 or 7c04-r workgroup smartswitch using the following steps and referring to the appropriate figure. Notes: the top slot in the 7c04 workgroup smartswitch is reserved for t...

  • Page 21

    3-6 installation/removal figure 3-4. Installing the 7f06-02 module in the 7c04 workgroup smartswitch figure 3-5. Installing the 7f06-02 module in the 7c04-r workgroup smartswitch sn 1 2 3 4 p s p s sp pwr sn m ac ad r cpu 7x00 sp sn 7a06-01 sp fans 4 3 2 1 pwr sn mac adr cpu 7f06-02 7x00 sp sp sp pw...

  • Page 22: Smartswitch

    Installation/removal 3-7 3.3.4 removing from the 7c04 or 7c04-r workgroup smartswitch the 7f06-02 module, inserted in the 7c04 or the 7c04-r workgroup smartswitch, can be removed whenever necessary. Follow the steps below and refer to the appropriate figure to remove the module. Note: before removin...

  • Page 23

    3-8 installation/removal figure 3-7. Removing the 7f06-02 module from the 7c04-r workgroup smartswitch fans sn 4 3 2 1 ejector tabs screws.

  • Page 24: Chapter  4

    4-1 chapter 4 troubleshooting the 7f06-02 module uses lanview, cabletron systems built-in visual diagnostic and status monitoring system. With lanview leds the status of each transmit and receive port on the 7f06-02 module can be determined, at a glance. This section discusses the function and purpo...

  • Page 25

    4-2 troubleshooting table 4-1 indicates the state of the receive port. Table 4-2 indicates the state of the transmit port. Table 4-1. Port receive leds led color state yellow (flashing) data activity (flashing to steady on indicates rate) off no activity, port can be disabled or enabled table 4-2. P...

  • Page 26

    Troubleshooting 4-3 table 4-3 indicates the state of the a/b link leds. Table 4-3. Link leds a p s b state green n/a n/a green ports enabled & active green green off green thru a, mac on primary, secondary bypasses board green green yellow green thru a, mac on primary, no mac on secondary green off ...

  • Page 27: Chapter  5

    5-1 chapter 5 technical specifications this chapter includes the technical specifications for cabletron systems 7f06-02 module. Cabletron systems reserves the right to change these specifications at any time without notice. 5.1 standards ieee 802.1d ieee 802.3i 10base-t 5.2 emi the emi requirements ...

  • Page 28

    5-2 technical specifications 5.5 safety it is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions. This equipment meets the safety requirements of: • ul 1950 • csa c22.2 no. ...