Cabletron Systems SmartCell ZX-250 Reference Manual

Other manuals for SmartCell ZX-250: Installation Manual, User Manual, Reference Manual
Manual is about: Enterasys SmartCell 6A000: Reference Guide ATM switch

Summary of SmartCell ZX-250

  • Page 1

    Smartcell 6a000/zx-250 reference manual 35 industrial way rochester, nh 03866-5005 usa (603) 332-9400 part # 04-0044-02 rev. A order # 9032400

  • Page 2

    Ii smartcell 6a000/zx-250 reference manual notice cabletron systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult cabletron systems to determine whether any such changes have been mad...

  • Page 3

    Smartcell 6a000/zx-250 reference manual iii revision history document name: smartcell 6a000/zx-250 reference manual document order number: order # 9032400 document part number: part # 04-0044-02 rev. A author: bruce jordan editor: carre gibson date revision description october 1997 a initial release.

  • Page 4

    Iv smartcell 6a000/zx-250 reference manual.

  • Page 5

    Smartcell 6a000/zx-250 reference manual v table of contents 1 introduction 1-1 audience and scope 1-1 definitions 1-1 content 1-1 sections 1-2 conventions 1-2 abbreviations 1-3 help options 1-4 other reference options 1-4 switch attribute 1-5 list of commands and possible switch attributes 1-9 2 con...

  • Page 6

    Vi smartcell 6a000/zx-250 reference manual table of contents ipatmstat 2-64 laneclient 2-66 lecs 2-68 lecsaddress 2-70 lecselan 2-72 lecselanlec 2-75 lecsstat 2-78 lecstlvparam 2-81 lecstlvset 2-83 lecsvcc 2-88 les 2-90 lesarp 2-91 lesclient 2-92 leselan 2-94 leslecstat 2-98 lesstat 2-100 log 2-103 ...

  • Page 7

    Smartcell 6a000/zx-250 reference manual vii table of contents switch 2-182 switchconfig 2-184 switchname 2-188 switchtrafficcongestion 2-189 trafficdescriptor 2-197 trustednms 2-199 uniroute 2-201 vccmask 2-204 wellknownaddress 2-206 3 boot load commands 3-1 accessing the boot load commands 3-2 chpi...

  • Page 8

    Viii smartcell 6a000/zx-250 reference manual table of contents.

  • Page 9

    Smartcell 6a000/zx-250 reference manual ix list of tables 1-1 list of operators 1-5 1-2 operator table explanation 1-6 1-3 parameter table explanation 1-7 1-4 description table explanation 1-8 1-5 description table example 1-8 2-1 filter flags 2-113 2-2 software modules for logtrace 2-116 2-3 softwa...

  • Page 10

    X smartcell 6a000/zx-250 reference manual list of tables.

  • Page 11

    Smartcell 6a000/zx-250 reference manual 1-1 1 introduction this reference manual describes the console commands for the smartcell 6a000 and smartcell zx-250 atm switches. The two switches share a common console interface and are referred to in this manual as the smartcell 6a000/zx-250. Audience and ...

  • Page 12

    1-2 smartcell 6a000/zx-250 reference manual introduction sections read "switch attribute" for an example and definition of the various sections under each switch attribute as well as a description of how the manual is organized. Each section begins with a switch attribute heading (for example, "pvcb...

  • Page 13

    Smartcell 6a000/zx-250 reference manual 1-3 introduction ip netmask : 255.255.255.0 ip/atm client 3 ============================================================================== client state : operational client address : 39:00:00:00:00:00:00:00:00:00:14:15:00:00:00:5a:01:01:7c:00 server : is local...

  • Page 14

    1-4 smartcell 6a000/zx-250 reference manual introduction help options if you want information on a specific command, type ? Or help before typing the command and you will get a brief description of the command and all its input parameters. If you want information about a specific input parameter whi...

  • Page 15

    Smartcell 6a000/zx-250 reference manual 1-5 introduction switch attribute this section—immediately below the heading—gives a brief description of what the switch attribute does. A detailed description of each command is available under "descriptions." "x" under any of these headings indicates the sw...

  • Page 16

    1-6 smartcell 6a000/zx-250 reference manual introduction operators parameters appear in the parameter tables in the same order and spelling as the switch shows them. Most switch attribute descriptions show two tables—input parameter and output parameter. If the parameter has already been described i...

  • Page 17

    Smartcell 6a000/zx-250 reference manual 1-7 introduction only one parameter table in a switch attribute section means either that switch attribute uses only input parameters or that the output parameters are identical to the input parameters. The heading of the table indicates which is the case. If ...

  • Page 18

    1-8 smartcell 6a000/zx-250 reference manual introduction descriptions the following is an example of a description section. It is located under "buselan." note the detailed description of the command following the table. Examples examples are copied exactly from the switch console to show you what y...

  • Page 19

    Smartcell 6a000/zx-250 reference manual 1-9 introduction switch_prompt # show buselan elannumber : 103 elan : elan103 elan number : 103 elan name : elan103 atm address :39:00:00:00:00:00:00:00:20:d4:14:15:00:00:20:d4:14:15:66:02 max frame size : 4544 connection method : pvc distribute vpi/vci: 0/50 ...

  • Page 20

    1-10 smartcell 6a000/zx-250 reference manual introduction modify (set) alarmconfig alarmverbose buselan cacparams ilmiadminstatus ipaddress ipatmclient laneclient lecsaddress lecselan lecselanlec lecstlvset leselan logalarmmask logbuffer logprint logtrace mynmaddr netprefix portautodetect portconifg...

  • Page 21

    Smartcell 6a000/zx-250 reference manual 1-11 introduction show (display) activate/deactivate alarm alarmconfig alarmverbose busclient buselan buslecstat busstat cacparams cacstat client clientarp clientstat clientvc community elan iisproute ilmiadminstatus ipatmarp ipatmpvc ipatmstat lecs lecsaddres...

  • Page 22

    1-12 smartcell 6a000/zx-250 reference manual introduction backup/restore clear disable/enable exit flush history switch alarm busstat config lesstat logbuffer logtrace portstat disable/enable exit alarm iisproute pvc uniroute wellknownaddress history.

  • Page 23

    Smartcell 6a000/zx-250 reference manual 1-13 introduction passwd restart setup shutdown start stop passwd client switch shutdown lecs les log ping lecs les log.

  • Page 24

    1-14 smartcell 6a000/zx-250 reference manual introduction update firmware.

  • Page 25

    Smartcell 6a000/zx-250 reference manual 2-1 2 console commands alarm use alarm to set alarm messaging features. Operators show, clear, flush parameters in the output parameter table below, ( ) indicates parameters that are available only through the show alarm /d (detailed) command. ( ) (summarized)...

  • Page 26

    2-2 smartcell 6a000/zx-250 reference manual console commands [timestamp] ( ) time (in system up time) when the alarm message entry was created. The time stamp is in the format [hrs:mins:secs:msecs]. N/a [message] ( ) numeric code that specifies the message in the log entry that generated this alarm ...

  • Page 28

    2-4 smartcell 6a000/zx-250 reference manual console commands examples (alarmverbose is off) switch_prompt # modify alarmverbose mode(on) : off setting alarm verbose mode to off switch_prompt # show alarm 1 /s ---------------------------------------------------- num mod submod t(h:m:s:ms) msg -------...

  • Page 29

    Smartcell 6a000/zx-250 reference manual 2-5 console commands writing into alarm configuration alarm directory : alarm alarm config file : alarmc.Db alarm filename : zalarm num of alarm files : 32 starting file number: 0 num of used files : 18 num of logs per file: 8 would you also like to clear this...

  • Page 30

    2-6 smartcell 6a000/zx-250 reference manual console commands alarmconfig use alarmconfig (alarm configuration) to determine alarm message buffer file configuration. Operators add, modify, show parameters server svc x x input parameter description value/field size default [alarmnumfiles] number of al...

  • Page 31

    Smartcell 6a000/zx-250 reference manual 2-7 console commands descriptions [alarm config file] name of the file that contains the current configuration of the alarm message buffer. Alarmc.Db [alarm filename] base name of the set of files within the flash file system where alarm messages are stored. A...

  • Page 32

    2-8 smartcell 6a000/zx-250 reference manual console commands examples switch_prompt # add alarmconfig alarmnumfiles(32) : startfilenum(0) : numfilesused(0) : numalarmsperfile(8): switch_prompt # switch_prompt # modify alarmconfig alarmnumfiles(32) : startfilenum(0) : numfilesused(0) : numalarmsperfi...

  • Page 33

    Smartcell 6a000/zx-250 reference manual 2-9 console commands alarmverbose use alarmverbose to determine how much information is displayed in the alarm messages. Operators modify, show parameter descriptions examples switch_prompt # modify alarmverbose mode(on): off setting alarm verbose mode to off ...

  • Page 34

    2-10 smartcell 6a000/zx-250 reference manual console commands busclient use busclient (broadcast and unknown server client) to manage the mapping between the buselan and the lane clients that have joined the buselan. Clients are uniquely identified by their lecid. Operators delete, show parameters d...

  • Page 35

    Smartcell 6a000/zx-250 reference manual 2-11 console commands examples switch_prompt # delete busclient elannumber(0) : lecid(0) : 14 lecid : 14 atmaddress : 39:00:00:00:00:00:00:00:20:d4:14:11:80:00:20:d4:00:d6:c0:00 confirm(y/n)? : y switch_prompt # switch_prompt # show busclient 0 client table en...

  • Page 36

    2-12 smartcell 6a000/zx-250 reference manual console commands buselan use buselan (broadcast and unknown server emulated lan) to determine the characteristics of the specified elan maintained by the bus. If the corresponding leselan exists, it should be identical. Operators add, delete, modify, show...

  • Page 37

    Smartcell 6a000/zx-250 reference manual 2-13 console commands parameters input parameter description value/field size default [elannumber] number of the elan to which the bus belongs. 0-127 all [elanname] name of the elan to which the bus belongs. Up to 32 characters elan000 [connectmethod] type of ...

  • Page 38

    2-14 smartcell 6a000/zx-250 reference manual console commands descriptions examples switch_prompt # add buselan elannumber(0) : 102 elanname(elan102) : connectmethod(svc) : elantype(802.3) : multipoint(yes) : mtu(1516) : switch_prompt # switch_prompt # delete buselan elannumber(0) : 3 elan number : ...

  • Page 39

    Smartcell 6a000/zx-250 reference manual 2-15 console commands the example below changes elan102 from an ethernet buselan to a token ring buselan, changing the mtu to reflect the change in elan type. It assumes the les has already been changed. Switch_prompt # modify buselan 102 elanname(elan102) : c...

  • Page 40

    2-16 smartcell 6a000/zx-250 reference manual console commands buslecstat use buslecstat (broadcast and unknown server lan emulation client statistics) to view traffic statistics for all or specified clients that have joined the buselan. Operator show parameters server svc x input parameter descripti...

  • Page 41

    Smartcell 6a000/zx-250 reference manual 2-17 console commands description example switch_prompt # show buslecstat elannumber(0) : lecid(0) : client statistics for elan elan000 =========================================================================== lecid : 1 atm address : 39:00:00:00:00:00:00:00:...

  • Page 42

    2-18 smartcell 6a000/zx-250 reference manual console commands busstat use busstat (broadcast and unknown server statistics) to view statistics that the bus maintains for each elan. Operators show, clear parameters server svc x input parameter description value/field size default [elannumber] number ...

  • Page 43

    Smartcell 6a000/zx-250 reference manual 2-19 console commands descriptions examples switch_prompt # show busstat 3 elan elan003 statistics out octets : 450432 out unicast : 7030 out multicast : 3 in octets : 450432 in unicast : 7030 in multicast : 3 frame timeouts : 0 vcc rejects : 0 switch_prompt #...

  • Page 44

    2-20 smartcell 6a000/zx-250 reference manual console commands cacparams use cacparams (call admission control parameters) to determine the allocation of bandwidth to svcs (switched virtual circuits) and pvcs (permanent virtual circuits) for individual ports on the switch. Operators modify, show para...

  • Page 45

    Smartcell 6a000/zx-250 reference manual 2-21 console commands descriptions examples switch_prompt # modify cacparams portnumber :( all ): a2 allocscheme :( ) : moderate switch_prompt # switch_prompt # modify cacparams portnumber :( all ): a3 allocscheme :( ) : liberal switch_prompt # switch_prompt #...

  • Page 46

    2-22 smartcell 6a000/zx-250 reference manual console commands cacstat use cacstat to see the cac (call admission control) statistics. Operator show parameters server svc x x input parameter description value/field size default [portnumber] port number on the switch. All, a1...A4, b1...B3, c1...C4, d...

  • Page 47

    Smartcell 6a000/zx-250 reference manual 2-23 console commands description examples switch_prompt # show cacstat portnumber(all) : port# bandwidth available bandwidth allocated (in kb/s) (in kb/s) total cbr rtvbr nrtvbr ubr ============================================================================ ...

  • Page 48

    2-24 smartcell 6a000/zx-250 reference manual console commands client use client to determine all or local lane (lan emulation) and ip/atm (ip over atm) clients on the switch. Operators delete, restart, show parameters in the output parameter table below, () appears next to parameters that are availa...

  • Page 49

    Smartcell 6a000/zx-250 reference manual 2-25 console commands descriptions [lecs address] () atm address of the lecs. [les address] () atm address of the lane server. [lan type] () type of elan. [mtu] () maximum transfer unit assigned for this client. [ip netmask] () ip netmask assigned to the clien...

  • Page 50

    2-26 smartcell 6a000/zx-250 reference manual console commands examples switch_prompt # delete client 4 ip/atm client4 address: 39:00:00:00:00:00:00:00:00:00:14:15:00:00:00:7a:01:01:5b:00 confirm(y/n)?:y switch_prompt # switch_prompt # show client clientnumber(all) : client type ip address server typ...

  • Page 51

    Smartcell 6a000/zx-250 reference manual 2-27 console commands with the following example (), notice how you get the same amount of detail whether you specify the client or accept the default “all”: switch_prompt # show client /d clientnumber(all) : lane client 1 =====================================...

  • Page 52

    2-28 smartcell 6a000/zx-250 reference manual console commands clientarp use clientarp (client address resolution protocol) to view the mapping of the mac (media access control) or ip addresses to an atm address for lane (lan emulation) or ip/atm (ip over atm) clients. Operator show parameters server...

  • Page 53

    Smartcell 6a000/zx-250 reference manual 2-29 console commands description example switch_prompt # show clientarp clientnumber(all) : lane client 0 arp table mac address atm address ============================================================================= 00:20:d4:14:15:00 39:00:00:00:00:00:00:00...

  • Page 54

    2-30 smartcell 6a000/zx-250 reference manual console commands clientstat use clientstat (client statistics) to view lane (lan emulation) or ip/atm (ip over atm) client statistics. Operator show parameters in the output parameter table below, () appears next to parameters that are available only thro...

  • Page 55

    Smartcell 6a000/zx-250 reference manual 2-31 console commands [broadcast packets] () number of broadcast packets received or transmitted. [error packets] () number of error packets received or transmitted. [dropped packets] () number of received or transmitted packets dropped. [bytes transmitted] ()...

  • Page 56

    2-32 smartcell 6a000/zx-250 reference manual console commands description examples the examples show statistics for all clients, detail () for all clients, an ip/atm client, and a lane client. Operator parameters/permissions description show clientstat (/d) [clientnumber] all displays the packet cou...

  • Page 57

    Smartcell 6a000/zx-250 reference manual 2-33 console commands switch_prompt # show clientstat clientnumber(all): client type rxpkts txpkts rxoctets txoctets ============================================================================ 1 lane 0 0 0 0 3 ip/atm 0 0 0 0 switch_prompt # switch_prompt # sh...

  • Page 58

    2-34 smartcell 6a000/zx-250 reference manual console commands switch_prompt # show clientstat 3 stats for ip/atm client 3 ============================================================================ rx stats bytes received : 0 unicast packets : 0 multicast packets : 0 broadcast packets : 0 error pac...

  • Page 59

    Smartcell 6a000/zx-250 reference manual 2-35 console commands clientvc use clientvc (client virtual circuit) to view which vcs are associated with a particular local lane or ip over atm client's arp (address resolution protocol) entries. Clientvc is similar to clientarp, except that it also includes...

  • Page 60

    2-36 smartcell 6a000/zx-250 reference manual console commands description example switch_prompt # show clientvc clientnumber(all) : lane client 0 vc table mac address vpi/vci atm address =========================================================================== 00:02:d4:14:22:80 0/2453 39:00:00:00:...

  • Page 61

    Smartcell 6a000/zx-250 reference manual 2-37 console commands community use community to group nms (network management system) hosts by privilege level. Hosts are collectively called communities, and their privilege level determines the type of information access permitted by the switch. The switch ...

  • Page 62

    2-38 smartcell 6a000/zx-250 reference manual console commands descriptions examples switch_prompt # add community name() : boris ipaddr() : 90.1.1.1 priviledge(read) : switch_prompt # switch_prompt # show community community name ip address privilege =================================================...

  • Page 63

    Smartcell 6a000/zx-250 reference manual 2-39 console commands config use config to erase the configuration information on the smartcell zx-250. Before using the clear config command, you should backup the switch configuration using the backup switch command. See page 182. Operator clear parameters s...

  • Page 64

    2-40 smartcell 6a000/zx-250 reference manual console commands description example switch_prompt # clear config you should backup your configuration using the "backup switch" command, in case you want to recover this configuration continuing will permanently erase the current switch configuration, an...

  • Page 65

    Smartcell 6a000/zx-250 reference manual 2-41 console commands elan use elan (emulated local area network) to create or delete elans on the switch. This is a quick configuration method of managing elan server entries within one command. For details of how to create or delete these entries individuall...

  • Page 66

    2-42 smartcell 6a000/zx-250 reference manual console commands descriptions output parameter description [les address] atm address of the lane server. [distribute vpi/vci] vpi/vci values of the control direct vcc or multicast send vcc. [distribute method] indicates whether the control distribute vcc ...

  • Page 67

    Smartcell 6a000/zx-250 reference manual 2-43 console commands examples switch_prompt # add elan elannumber(0) : 11 elanname(elan011) : connectmethod(svc) : elantype(802.3) : multipoint(yes) : mtu(1516) : distribute(proxy) : switch_prompt # switch_prompt # delete elan elannumber(0): 11 confirm(y/n)?:...

  • Page 68

    2-44 smartcell 6a000/zx-250 reference manual console commands b switch_prompt # add leselan 4 elanname(elan004) : connectmethod(svc) : elantype(802.3) : multipoint(yes) : mtu(1516) : distribute(proxy) : busatmaddress() : switch_prompt # switch_prompt # add buselan 4 elanname(elan004) : connectmethod...

  • Page 69

    Smartcell 6a000/zx-250 reference manual 2-45 console commands exit use exit to disconnect your console connection from the switch. Operator exit parameters there are no parameters for this command. Just type exit at the switch prompt. Description example switch_prompt # exit exiting smartcell 2x com...

  • Page 70

    2-46 smartcell 6a000/zx-250 reference manual console commands firmware use firmware to re-program the switch application software when you want to perform a switch upgrade. Operator update parameters description server svc x x input parameter description value/field size default [serverip] ip addres...

  • Page 71

    Smartcell 6a000/zx-250 reference manual 2-47 console commands example smartcell zx # update firmware serverip() :204.95.77.240 path() :server/server.Ima you are updating the code image in the flash. Are you sure this is what you want to do? Confirm(y/n)?:y verifying bootfile server/server.Ima on 204...

  • Page 72

    2-48 smartcell 6a000/zx-250 reference manual console commands history use history to view the last five commands you entered. Enter history if you want to use one of those commands again. Operator history parameters this command has no parameters. Just type history at the switch prompt. Description ...

  • Page 73

    Smartcell 6a000/zx-250 reference manual 2-49 console commands iisproute use iisproute (interim inter-switch signaling protocol) to manipulate the iisp routes configured on the switch (see “uniroute” for further routing commands). Operators add, delete, show, flush parameters server svc x x input par...

  • Page 74

    2-50 smartcell 6a000/zx-250 reference manual console commands descriptions you can create a default iisp route if you enter only the port number and a weighting value [metric] for the route (see examples below). You can set multiple local configurations to choose one of the parallel links for next-h...

  • Page 75

    Smartcell 6a000/zx-250 reference manual 2-51 console commands examples switch_prompt # add iisproute atmaddress() : 39:00:00:00:00:00:00:00:00:00:11:22:33 portnumber(a1): metric(1) : switch_prompt # add iisproute atmaddress() : 39:00:00:00:00:00:00:00:00:00:11:22:44 portnumber(a1): metric(1) : 2 swi...

  • Page 76

    2-52 smartcell 6a000/zx-250 reference manual console commands ilmiadminstatus use ilmiadminstatus (integrated local management interface administration status) to control the operation of the ilmi protocol on every port on the switch. Operators modify, show parameters descriptions server svc x x inp...

  • Page 77

    Smartcell 6a000/zx-250 reference manual 2-53 console commands examples switch_prompt # modify ilmiadminstatus portnum :( all ): a1 ilmiadminstatus :( enable ): disable switch_prompt # switch_prompt # show ilmiadminstatus portnum :( all ): port# ilmi admin status =====================================...

  • Page 78

    2-54 smartcell 6a000/zx-250 reference manual console commands ipaddress use ipaddress to change ip addresses of the ethernet port and ip netmask on the switch. Operator modify parameters description server svc x x input parameter description value/field size default [ipaddress] ip address of the eth...

  • Page 79

    Smartcell 6a000/zx-250 reference manual 2-55 console commands example switch_prompt # modify ipaddress ipaddress(200.30.72.122) : 1.1.1.11 ipnetmask(255.255.255.0) : confirm(y/n)?: y changing ip address on system. Telnet session (if any) will be lost. Switch_prompt #.

  • Page 80

    2-56 smartcell 6a000/zx-250 reference manual console commands ipatmarp use ipatmarp (ip over atm address resolution protocol) to see ip/atm arp server tables. Unlike lane client or ip/atm (ip over atm) client arp tables (see show clientarp ), these arp entries are registered with the ip/atm arp serv...

  • Page 81

    Smartcell 6a000/zx-250 reference manual 2-57 console commands ipatmclient use ipatmclient (ip over (/) atm client) to manipulate either local ip/atm clients or ip/atm clients acting as an ip/atm server, or if you want to configure an ip/atm client on the ip/atm server itself. Operators add, modify, ...

  • Page 82

    2-58 smartcell 6a000/zx-250 reference manual console commands parameters input parameter description value/field size default [clientnumber] number of the client. 0-127 all [servertype] ip/atm server type. Local, external, none none [serveraddress] atm address of the ip/atm server. If [servertype]st...

  • Page 83

    Smartcell 6a000/zx-250 reference manual 2-59 console commands descriptions examples switch_prompt # add ipatmclient clientnumber(0) : 50 servertype(none) : local serveraddr() : ipaddr() : 101.1.1.50 netmask(255.0.0.0): mtu(9180) : switch_prompt # switch_prompt # add ipatmclient clientnumber(0) : 1 s...

  • Page 84

    2-60 smartcell 6a000/zx-250 reference manual console commands netmask(255.0.0.0): mtu(9180) : switch_prompt # switch_prompt # modify ipatmclient clientnumber(0) : 50 servertype(local) : serveraddr() : ipaddr(101.1.1.50): 101.1.1.150 netmask(255.0.0.0): mtu(9180) : switch_prompt # show client switch_...

  • Page 85

    Smartcell 6a000/zx-250 reference manual 2-61 console commands ipatmpvc use ipatmpvc (ip over atm permanent virtual circuit) to manipulate ip/atm pvc clients on a pvc ip/atm vlan (virtual lan). Operators add, delete, show parameters server svc x x input parameter description value/field size default ...

  • Page 86

    2-62 smartcell 6a000/zx-250 reference manual console commands descriptions examples switch_prompt #add pvc conntype(ptp) : lowport(a1) : lowvpi(0) : lowvci(33) : 130 highport(a1) : b4 highvpi(0) : highvci(34) : 130 fwd iptorindex(1) : bkwtrafficdescriptorindex(1) : switch_prompt # switch_prompt #sho...

  • Page 87

    Smartcell 6a000/zx-250 reference manual 2-63 console commands switch_prompt #show client 0 ip/atm client 0 =========================================================================== client state : operational client address : 39:00:00:00:00:00:00:00:20:d4:14:22:80:00:00:0a:01:01:02:00 server : is n...

  • Page 88

    2-64 smartcell 6a000/zx-250 reference manual console commands ipatmstat use ipatmstat (ip over atm statistics) to view details of the ip/atm (ip over atm) client server. Operator show parameters server svc x input parameter description value/field size default [clientnumber] number of the client. 0-...

  • Page 89

    Smartcell 6a000/zx-250 reference manual 2-65 console commands description examples switch_prompt # show ipatmstat clientnumber(all): client arpreqs arpreps arpunrch arpnaks =========================================================================== 50 0 0 0 0 51 0 0 0 0 switch_prompt # switch_prompt...

  • Page 90

    2-66 smartcell 6a000/zx-250 reference manual console commands laneclient use laneclient (local area network emulation client) to allow inband management of lane clients on the switch. Operators add, modify, (show client) parameters server svc x x input parameter description value/field size default ...

  • Page 91

    Smartcell 6a000/zx-250 reference manual 2-67 console commands description examples switch_prompt # add laneclient clientnumber(0) :100 lanname(elan100): servertype(lecs): serveraddress() :39:00:00:00:00:00:11:11:11:11:11:11:11:00:11:22:22:44:55:01 ipaddress() :101.1.1.100 netmask(255.0.0.0): mtu(151...

  • Page 92

    2-68 smartcell 6a000/zx-250 reference manual console commands lecs use lecs (local area network emulation configuration server) to manage the operational status of the lecs on the network. Operators start, stop parameters this command has no parameters. Just type start lecs or stop lecs at the switc...

  • Page 93

    Smartcell 6a000/zx-250 reference manual 2-69 console commands examples switch_prompt # start lecs notice - 'lecs' ***** lecs started ***** switch_prompt # switch_prompt # stop lecs notice - 'lecs' ***** lecs exiting ***** switch_prompt #.

  • Page 94

    2-70 smartcell 6a000/zx-250 reference manual console commands lecsaddress use lecsaddress (lan emulation configuration server atm address) to configure addresses on the switch. This address identifies the lecs on the network that will be contacted for information when lan emulation is used. While th...

  • Page 95

    Smartcell 6a000/zx-250 reference manual 2-71 console commands examples switch_prompt # add lecsaddress lecsaddress :39:00:00:00:00:00:11:22:33:44:55:66:77:11:22:33:44:55:66:01 switch_prompt # switch_prompt # delete lecsaddress confirm? (y/n): y switch_prompt # switch_prompt # modify lecsaddress lecs...

  • Page 96

    2-72 smartcell 6a000/zx-250 reference manual console commands lecselan use lecselan (lan emulation configuration server emulated lan) to manage the lecs entries on the elan. Operators add, delete, modify, show parameters server svc x parameter description value/field size default [elannumber] number...

  • Page 97

    Smartcell 6a000/zx-250 reference manual 2-73 console commands descriptions examples switch_prompt # add lecselan elannumber(0) : 4 elanname(elan004) : lesaddress(39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:d4:14:15:04:02): elantype(802.3) : mtu(1516) : tlvset() : switch_prompt # switch_prompt # del...

  • Page 98

    2-74 smartcell 6a000/zx-250 reference manual console commands switch_prompt # modify lecselan elannumber(0) : elanname(elan1) : lesaddress(39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:d4:14:15:00:02): 39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:d4:14:15:00:04 elantype(802.3) : mtu(1516) : tlvset() ...

  • Page 99

    Smartcell 6a000/zx-250 reference manual 2-75 console commands lecselanlec use lecselanlec (lan emulation configuration server emulated lan lane client) to manage the way lane clients are assigned to a specified elan on the lecs. Operators add, delete, modify, show parameters server svc x parameter d...

  • Page 100

    2-76 smartcell 6a000/zx-250 reference manual console commands descriptions operator parameters/permissions description add lecselanlec [lecaddress] clientatmaddress> [macaddress/routedesc] [elannumber] administrator adds a lane client to an existing elan on the lecs. The client must have a unique at...

  • Page 101

    Smartcell 6a000/zx-250 reference manual 2-77 console commands examples switch_prompt # add lecselanlec lecaddress: 39:00:00:00:00:00:00:00:00:00:14:7b:00:00:20:d4:14:7b:00:01 macaddress/routedesc: 01:02:03:04:05:06 elannumber(0):1 switch_prompt # switch_prompt # delete lecselanlec lecaddress/macddre...

  • Page 102

    2-78 smartcell 6a000/zx-250 reference manual console commands lecsstat use lecsstat (lan emulation configuration server statistics) to see statistical information about incoming configuration requests to the lecs. Operator show server svc x.

  • Page 103

    Smartcell 6a000/zx-250 reference manual 2-79 console commands parameters output parameter description [successful configuration requests] number of successful configuration requests. [bad configuration requests] number of bad configuration requests. [invalid request parameters] number of configurati...

  • Page 104

    2-80 smartcell 6a000/zx-250 reference manual console commands description example switch_prompt # show lecsstat statistics on lecs =========================================================================== successful configuration requests : 3 bad configuration requests : 0 invalid request paramete...

  • Page 105

    Smartcell 6a000/zx-250 reference manual 2-81 console commands lecstlvparam use lecstlvparam (lan emulation configuration server type, length, and value parameters) to remove a specific tlv parameter from the tlv set on the lecs. Operator delete parameters description examples the show lecstlvset exa...

  • Page 106

    2-82 smartcell 6a000/zx-250 reference manual console commands switch_prompt # show lecstlvset tlvsetnumber(all) :2 tlvindex tlvdescription value =========================================================================== tlvset 2 : 1 control timeout 200 2 max unknown frame time 4 6 arp aging time 25...

  • Page 107

    Smartcell 6a000/zx-250 reference manual 2-83 console commands lecstlvset use lecstlvset (lan emulation configuration server type, length, and value set) to manipulate tlv parameters on the lecs. A tlv set is a collection of tlv parameters associated with an elan (emulated lan). Operators add, delete...

  • Page 108

    2-84 smartcell 6a000/zx-250 reference manual console commands [arpresponsetime] maximum time that the lec expects a request/response cycle to take. Seconds/1-30 n/a [flushtimeout] time limit on flush response after flush request has been sent, before taking recovery action. Seconds/1-4 n/a [pathswit...

  • Page 109

    Smartcell 6a000/zx-250 reference manual 2-85 console commands descriptions operator parameters/permissions description add lecstlvset [tlvsetnumber] tlvsetnumber> [controltimeout] controltimeout> [maxunknownframecount] maxunknframecount> [maxunknownframetime] maxunknframetime> [vcctimeout] vcctimeou...

  • Page 110

    2-86 smartcell 6a000/zx-250 reference manual console commands examples switch_prompt # add lecstlvset tlvsetnumber[1-32767](1) : 3 controltimeout[10-300]() : 200 maxunknownframecount[1-10]() : 5 maxunknownframetime[1-60]() : 50 vcctimeout[0-65535]() : 50000 maxretrycount[0-2]() : 1 arpagingtime[10-3...

  • Page 111

    Smartcell 6a000/zx-250 reference manual 2-87 console commands 3 max unknown frame time 40 4 vcc timeout 40000 5 max retry count 2 6 arp aging time 200 7 forward delay 20 8 arp response time 20 9 flush timeout 3 10 path switching delay 5 11 local seg id 2500 12 multicast send vcc type 2 15 connection...

  • Page 112

    2-88 smartcell 6a000/zx-250 reference manual console commands lecsvcc use lecsvcc (lan emulation configuration server virtual channel connection) to view the vccs that are waiting to join the lecs. These vccs are set up by the lane client (or other entity) as part of the lecs connection. As soon as ...

  • Page 113

    Smartcell 6a000/zx-250 reference manual 2-89 console commands example switch_prompt # show lecsvcc vc type vpi/vci =========================================== pvc 0/31 pvc 0/33 svc 0/112 switch_prompt #.

  • Page 114

    2-90 smartcell 6a000/zx-250 reference manual console commands les use les (lan emulation server) to control the status of the les and bus (broadcast and unknown server) servers which are co-located. You can control both servers using les. Operators start, stop parameters this command has no paramete...

  • Page 115

    Smartcell 6a000/zx-250 reference manual 2-91 console commands lesarp use lesarp (lan emulation server address resolution protocol) to see details of the clients registered with the les. Lesarp also gives the mac (media access control) address of the client. Operator show parameter description exampl...

  • Page 116

    2-92 smartcell 6a000/zx-250 reference manual console commands lesclient use lesclient (lan emulation server client) to determine mapping between leselans and the lane (lan emulation) clients that have joined the specified elan (emulated lan). Clients are uniquely identified by their lecid. Operators...

  • Page 117

    Smartcell 6a000/zx-250 reference manual 2-93 console commands descriptions examples switch_prompt # delete lesclient elannumber (0): lecid (0) : 12 confirm? (y/n) : y switch_prompt # switch_prompt # show lesclient elannumber (0): client table entries for elan elan000 ================================...

  • Page 118

    2-94 smartcell 6a000/zx-250 reference manual console commands leselan use leselan (lan emulation server emulated lan) to manage the properties of the specified elan maintained by the les. If the corresponding buselan exists, it should have the same characteristics as the leselaln. Operators add, del...

  • Page 119

    Smartcell 6a000/zx-250 reference manual 2-95 console commands descriptions output parameter description [atm address] atm address of the les on the elan. [distribute vpi/vci] vpi/vci values of the control direct vcc or multicast send vcc. [distribute method] indicates whether the control distribute ...

  • Page 120

    2-96 smartcell 6a000/zx-250 reference manual console commands examples the following example creates elan 102 with default parameters for les: switch_prompt # add leselan elannumber(0) : 102 elanname(elan102) : connectmethod(svc) : elantype(802.3) : multipoint(yes) : mtu(1516) : distribute(proxy) : ...

  • Page 121

    Smartcell 6a000/zx-250 reference manual 2-97 console commands the following example resets an elan with default parameters: switch_prompt # modify leselan elannumber(0) : 102 elanname(elan102) : connectmethod(svc) : elantype(802.3) : multipoint(yes) : mtu(1516) : 9234 distribute(proxy) : busatmaddre...

  • Page 122

    2-98 smartcell 6a000/zx-250 reference manual console commands leslecstat use leslecstat (lan emulation server lan emulation client statistics) to view details of control traffic between the les and its lane (lan emulation) clients. You can see information on all or specified clients that are on that...

  • Page 123

    Smartcell 6a000/zx-250 reference manual 2-99 console commands description examples switch_prompt # show leslecstat elannumber(0) : lecid(0) : 3 client 3 statistics for elan elan000 =========================================================================== atm address : 39:00:00:00:00:00:00:00:20:d4...

  • Page 124

    2-100 smartcell 6a000/zx-250 reference manual console commands lesstat use lesstat (lan emulation server statistics) to manage the statistics that the les maintains for each elan. Operators show, clear parameters server svc x input parameter description value/field size default [elannumber] number o...

  • Page 125

    Smartcell 6a000/zx-250 reference manual 2-101 console commands descriptions [reg. Duplicate atm destination errors] duplicate atm address errors for register request. [join insufficient resource errors] insufficient resources to grant errors for join request. [reg. Insufficient resource errors] insu...

  • Page 126

    2-102 smartcell 6a000/zx-250 reference manual console commands examples switch_prompt # show lesstat elannumber(all) :102 elan : elan102 statistics join ok : 0 join version not supported errors : 0 reg. Version not supported errors : 0 unreg. Version not supported errors : 0 join invalid request par...

  • Page 127

    Smartcell 6a000/zx-250 reference manual 2-103 console commands log use log to control log message recording onto the log message buffer. Operators start, stop parameters this command has no parameters. Just type start log or stop log at the switch prompt. Descriptions examples switch_prompt # start ...

  • Page 128

    2-104 smartcell 6a000/zx-250 reference manual console commands logalarmmask use logalarmmask to determine—by setting masking flags—which log messages generate alarms. Operators modify, show parameters for more options see [filterflags] input parameter under “logtrace”. Server svc x x parameter descr...

  • Page 129

    Smartcell 6a000/zx-250 reference manual 2-105 console commands descriptions examples switch_prompt # modify logalarmmask emergency(n):y alert(n) : critical(n) : error(n) : warning(n) :y notice(n) : info(n) : debug(n) : trace(n) : alarm(n) : switch_prompt # switch_prompt # show logalarmmask switchnam...

  • Page 130

    2-106 smartcell 6a000/zx-250 reference manual console commands logbuffer use logbuffer if you want to record your messages on the log message buffer. Operators modify, show, clear parameters server svc x x input parameter description value/field size default [logbuffersize] size of the message log b...

  • Page 131

    Smartcell 6a000/zx-250 reference manual 2-107 console commands descriptions examples switch_prompt # modify logbuffer logbuffersize(10240): 7000 switch_prompt # switch_prompt # show logbuffer index(all) : ---------------------------------------------------- num mod submod t(h:m:s:ms) msg -----------...

  • Page 132

    2-108 smartcell 6a000/zx-250 reference manual console commands logbuffersize use logbuffersize to determine the size of the log buffer. Operator show parameter description example switch_prompt # show logbuffersize log buffer size: 7000 switch_prompt # server svc x x parameter description value/fiel...

  • Page 133

    Smartcell 6a000/zx-250 reference manual 2-109 console commands logprint use logprint to print log messages on the console. Operators modify, show parameters descriptions server svc x x input parameter description value/field size default [logprint] enables or disables printing of log messages to the...

  • Page 134

    2-110 smartcell 6a000/zx-250 reference manual console commands examples switch_prompt # modify logprint logprint(off) :on switch_prompt # switch_prompt # show logprint printing log messages on console : on switch_prompt #.

  • Page 135

    Smartcell 6a000/zx-250 reference manual 2-111 console commands logtrace use logtrace to control filtering and configuration parameters for logging and tracing messages. Operators modify, show parameters server svc x x parameter description value/field size default [localportnum] the port through whi...

  • Page 136

    2-112 smartcell 6a000/zx-250 reference manual console commands [filter parm val] user-specified parameter value. Log trace filters messages so that only those with a parameter equal to the specified value are printed. Use in conjunction with [filter parm pos] to identify in which position the parame...

  • Page 137

    Smartcell 6a000/zx-250 reference manual 2-113 console commands [quiet mode] suppresses the printing of messages to the console but continues to forward messages to clients. On/off on [start record] starting record for message range. Log trace prints messages within specified range. If both starting ...

  • Page 138

    2-114 smartcell 6a000/zx-250 reference manual console commands descriptions notice messages only 32 information messages only 64 debug messages only 128 trace messages only 256 alarm messages only 512 operator parameters/permissions description modify logtrace [filter parm pos] filterparamposition> ...

  • Page 139

    Smartcell 6a000/zx-250 reference manual 2-115 console commands show logtrace all displays the parameters of the currently configured log trace. Logged messages can also generate alarms, depending on how the log alarm mask is configured. Setting the log trace opens a tcp port through which other log ...

  • Page 140

    2-116 smartcell 6a000/zx-250 reference manual console commands examples switch_prompt # modify logtrace localportnum(6005) : logbuffersize(1000) :1300 outputtype(ascii) : endrecordnum(-1) : filtermodid(0) :off filtersubmodid(0) :off filtermsgid(0) : filterparamval(-1) : filterparampos(0) : filtersea...

  • Page 141

    Smartcell 6a000/zx-250 reference manual 2-117 console commands cons console specific hw hardware specific ilmi ilmi module ipsr ip over atm server lec lan emulation client lecs lan emulation configuration server les lan emulation server s10d s10 driver specific sig signaling sys system specific vx v...

  • Page 142

    2-118 smartcell 6a000/zx-250 reference manual console commands module id - be bear bridged ethernet address resolution protocol functions becf bridged ethernet configuration specific module id - hw link link specific swit switch fabric syst overall system specific module id - ilmi addr atm address a...

  • Page 143

    Smartcell 6a000/zx-250 reference manual 2-119 console commands module id - ilmi ilmn main functions imsc miscellaneous functions itmr timers msgh message handlers port port functions req request handlers slos solaris specific operating system ume uni management entity vxos vxworks specific operating...

  • Page 144

    2-120 smartcell 6a000/zx-250 reference manual console commands module id - lec ctl control specific data data specific def default message err errors ilmc ilmi specific init initialization ipat ip over atm client lecs lecs specific log log specific mibc mib client specific rd route descriptor send s...

  • Page 145

    Smartcell 6a000/zx-250 reference manual 2-121 console commands module id - lecs csil ilmi functions csin initialization function cssg signaling functions cstm timer functions csut utilities functions csvl vlan specific ctlc control functions db database functions glob global functions memb member fu...

  • Page 146

    2-122 smartcell 6a000/zx-250 reference manual console commands module id - les mibs mib specific prot prototype specific sigs signaling specific smn main functions smsc miscellaneous vlan vlan specific functions module id - s10d diag diagnostics isr interrupt service routine sif interface sint initi...

  • Page 147

    Smartcell 6a000/zx-250 reference manual 2-123 console commands module id - sig qs31 qsaal3.1 specific q293 q.2931 signaling module id - sys file flash file system related saal atm adaptation layer related smp packet memory related module id - vx sbuf buffers related smem memory related sspc heap rel...

  • Page 148

    2-124 smartcell 6a000/zx-250 reference manual console commands mynmaddr use mynmaddr (my network management address) to manage the switch through the specified ip address. Operators modify, show parameters descriptions server svc x x parameter description value/field size default [ipaddr] ip address...

  • Page 149

    Smartcell 6a000/zx-250 reference manual 2-125 console commands examples switch_prompt # modify mynmaddr ipaddr() : 204.95.75.186 my nm ip-address : 204.95.75.186 switch_prompt # switch_prompt # show mynmaddr my nm ip-address : 204.95.75.186 switch_prompt #.

  • Page 150

    2-126 smartcell 6a000/zx-250 reference manual console commands netprefix use netprefix to manipulate network atm address prefixes on a particular port. This 13-byte net prefix is based on a hierarchical addressing scheme. The default value starts with the first byte being set to 39 (dcc address form...

  • Page 151

    Smartcell 6a000/zx-250 reference manual 2-127 console commands examples switch_prompt # modify netprefix portnumber(all) :a1 netprefix(39:00:00:00:00:00:00:00:00:00:20:d4:14:15:00): 39:00:00:00:00:00:00:00:77:88:99:10:11:12:01 switch_prompt # switch_prompt # show netprefix portnumber :( all ):a1 por...

  • Page 152

    2-128 smartcell 6a000/zx-250 reference manual console commands passwd use passwd (password) to change the password of the current or lower-privileged user. Operator passwd parameters description example switch_prompt # passwd old password: admin changing password for user administrator new password:...

  • Page 153

    Smartcell 6a000/zx-250 reference manual 2-129 console commands ping use ping to test ip (internet protocol) connectivity of a client. However, the client must be on the same subnet or be reachable by routing from the subnet that is pinging . Operator start parameters description example switch_promp...

  • Page 154

    2-130 smartcell 6a000/zx-250 reference manual console commands portautodetect use portautodetect to manage the automatic-detection features of the switch on an individual port basis. Operators modify, show parameters server svc x x input parameter description value/field size default [autodetecttype...

  • Page 155

    Smartcell 6a000/zx-250 reference manual 2-131 console commands descriptions examples switch_prompt # modify portautodetect autodetecttype(all) : sigtype portnumber(all) : a1 value(on) : off switch_prompt # switch_prompt # show portautodetect autodetecttype(all) : portnumber(all) : portnumber autodet...

  • Page 156

    2-132 smartcell 6a000/zx-250 reference manual console commands portconfig use portconfig (port configuration) to manage the configuration of a port on the switch. Operators modify, show parameters server svc x x input parameter description value/field size default [portnumber] port number on the swi...

  • Page 157

    Smartcell 6a000/zx-250 reference manual 2-133 console commands [port qsaal state] signaling aal (atm adaptation layer). Indicates if the sscop (service specific connection oriented protocol) link is up or down. Up, down up [port operational state] state of the link, based on port status (set by inte...

  • Page 158

    2-134 smartcell 6a000/zx-250 reference manual console commands descriptions examples switch_prompt # modify portconfig portnumber(a1) : maxvpibits(0) : maxvcibits(12) : interfaceaddresstype(private) : switch_prompt # [current vci bits] current vci bits are derived from the vpi/vci set closest to the...

  • Page 159

    Smartcell 6a000/zx-250 reference manual 2-135 console commands the following examples show the port configuration of all ports, port a4, and then port b4 (cpu port): switch_prompt # show portconfig portnumber(all) : port id trans media speed admin op qsaal type type (mb/s) state state state ========...

  • Page 160

    2-136 smartcell 6a000/zx-250 reference manual console commands current vpi bits : 0 current vci bits : 12 current in use vccs : 24 port b4(cpu) configuration current max vccs : 4096 switch_prompt # switch_prompt # show portconfig /d portnumber(all) : port a1 configuration ===========================...

  • Page 161

    Smartcell 6a000/zx-250 reference manual 2-137 console commands portmode use portmode to control the port framing protocol on the switch when communicating with other switches that use different standards (such as the european sdh type). Operators modify, show server svc x x.

  • Page 162

    2-138 smartcell 6a000/zx-250 reference manual console commands parameters descriptions input parameter description field size/value default [portnumber] port number on the switch. All, a1...A4, b1...B4, c1...C4, d1...D4 all [portmode] physical mode type of the port. Sonet, sdh sonet output parameter...

  • Page 163

    Smartcell 6a000/zx-250 reference manual 2-139 console commands examples switch_prompt # modify portmode portnumber(all) : a1 portmode(sonet) : sdh switch_prompt # switch_prompt # show portmode portnumber(all) : port id frame type ======================================================================...

  • Page 164

    2-140 smartcell 6a000/zx-250 reference manual console commands portstat use portstat (port statistics) to manage traffic statistics for a given port or all ports. These statistics relate to network resources management, congestion, and performance issues. Operators show, clear parameter server svc x...

  • Page 165

    Smartcell 6a000/zx-250 reference manual 2-141 console commands descriptions examples switch_prompt # show portstat portnumber(all) : port id oam rm clp1 unk vc clp1 total recvd recvd recvd dropped dropped dropped ============================================================================ a1 0 0 0 0...

  • Page 166

    2-142 smartcell 6a000/zx-250 reference manual console commands unknown vc cells dropped : 0 clp1 cells dropped : 0 total cells dropped : 0 port a3 statistics ============================================================================ oam cells received : 0 rm cells received : 0 clp1 cells received ...

  • Page 167

    Smartcell 6a000/zx-250 reference manual 2-143 console commands porttrafficcongestion use porttrafficcongestion (port traffic congestion) to manage traffic congestion parameter for the specified port. Operators modify, show parameter descriptions server svc x x parameter description value/field size ...

  • Page 168

    2-144 smartcell 6a000/zx-250 reference manual console commands examples switch_prompt # modify portrafficcongestion port(all) : queue1minimumcellcounter(0) : 40 queue2minimumcellcounter(0) : 40 queue3minimumcellcounter(0) : 40 queue4minimumcellcounter(0) : 40 queue1maximumcellcounter(4096) : 2000 qu...

  • Page 169

    Smartcell 6a000/zx-250 reference manual 2-145 console commands privilege use privilege to manage the privilege level of the current user. Operators show, enable, disable parameter descriptions server svc x x input parameter description value/field size default [password] current password for that pr...

  • Page 170

    2-146 smartcell 6a000/zx-250 reference manual console commands examples switch_prompt # show privilege the current user is administrator switch_prompt # switch_prompt # enable password: ******** switch_prompt # disable the current user is readonly switch_prompt #.

  • Page 171

    Smartcell 6a000/zx-250 reference manual 2-147 console commands prompt use prompt to control how the switch prompt is displayed on the console monitor. Operator modify parameter descriptions example switch_prompt # set prompt prompt(switch_prompt) : my_switch my_switch # server svc x x input paramete...

  • Page 172

    2-148 smartcell 6a000/zx-250 reference manual console commands pvc use pvc (permanent virtual circuit) to manage pvcs on specific ports configured on the switch. Operators add, delete, activate, deactivate, show parameters server svc x x input parameter description value/field size default [conntype...

  • Page 173

    Smartcell 6a000/zx-250 reference manual 2-149 console commands in the output parameter table below, () appears next to the parameter that is available only through the show pvc /d (detailed) command. When () appears next to a parameter, the parameter appears in both the summarized table and the deta...

  • Page 174

    2-150 smartcell 6a000/zx-250 reference manual console commands [low to high operational status] ( /d >) status of the forward connection. Status is from the low-to-high vcl (virtual channel link)—the connection between host and switch. Up, down [high to low operational status] ( /d >) status of the ...

  • Page 175

    Smartcell 6a000/zx-250 reference manual 2-151 console commands [number of epd packets dropped in the fwd direction] ( /d >) number of epd (early packet discard) packets dropped in the forward direction of this cross-connect. Updated every 40 seconds. 1, 2, 3, 4.../ n/a [bkw traffictype] ( /d >) traf...

  • Page 176

    2-152 smartcell 6a000/zx-250 reference manual console commands descriptions operator parameters/permissions description add pvc [conntype] connectiontype> [lowport] lowport> [lowvpi] lowvpi> [lowvci] lowvci> [highport] highport> [highvpi] highvpi> [highvci] highvci> [fwdtrafficdescindex] fwdtrafficd...

  • Page 177

    Smartcell 6a000/zx-250 reference manual 2-153 console commands you can create either a ptp (point-to-point) or pmp (point-to-multipoint) pvc when you define the ports and low identifiers [vci] and [vpi]. To send traffic from one port to multiple ports, enter the same low port and low identifiers for...

  • Page 178

    2-154 smartcell 6a000/zx-250 reference manual console commands standard report switch_prompt # show pvc d2 crossconnid :( all ): conn conn traffic conn low high admin id subid type type port vpi/vci port vpi/vci status =========================================================================== 00024...

  • Page 179

    Smartcell 6a000/zx-250 reference manual 2-155 console commands detailed report for one port ( [/d b2] ) switch_prompt # show pvc /d b2 crossconnectid(all) : show cross connection in detailed mode ============================================================================== cross connect id : 4099 c...

  • Page 180

    2-156 smartcell 6a000/zx-250 reference manual console commands backward traffic type : nrtvbr backward bandwidth allocated in kb/s : 411 backward priority queue : medium-low bkwd early packet discard(for lower threshold of congestion) : disabled bkwd early packet discard(for higher threshold of cong...

  • Page 181

    Smartcell 6a000/zx-250 reference manual 2-157 console commands pvcbyid use pvcbyid (permanent virtual circuit by identification number) to manage cross-connect based pvcs on a cross-connect id or sub id. Operators activate, deactivate, delete parameters descriptions server svc x x input parameter de...

  • Page 182

    2-158 smartcell 6a000/zx-250 reference manual console commands examples switch_prompt # activate pvcbyid crossconnid(0) : 4097 crossconnsubid(0) : 2061 switch_prompt # switch_prompt # delete pvcbyid crossconnid:(0) : 24 crossconnsubid:(0) : 49 confirm? (y/n) : y switch_prompt # delete pvcbyid [cross...

  • Page 183

    Smartcell 6a000/zx-250 reference manual 2-159 console commands reboot use reboot to reboot the switch. Enter reboot with caution as it is instantly entered without offering the chance to confirm your decision. Operator reboot parameters this command has no parameters. Just type reboot at the switch ...

  • Page 184

    2-160 smartcell 6a000/zx-250 reference manual console commands example switch_prompt # reboot luxor start-up code version 1.0.0, nov 13 1996 copyright 1995, zeitnet inc. Cpu board details: board revision: 1 cpu speed: 25 mhz. Common dram base address: e0000000, size: 8 mb. No cpu dram. Secondary fla...

  • Page 185

    Smartcell 6a000/zx-250 reference manual 2-161 console commands route use route to administer ip (internet protocol) route management to an atm client through an ethernet network. It allows network management software to communicate across a network of switches. Operators add, delete, show parameters...

  • Page 186

    2-162 smartcell 6a000/zx-250 reference manual console commands descriptions examples switch_prompt # add route destnetip() : 204.95.77.187 gatewayip() : 204.95.77.186 switch_prompt # switch_prompt # show route route net table destination gateway flags refcnt use interface ---------------------------...

  • Page 187

    Smartcell 6a000/zx-250 reference manual 2-163 console commands rows use rows to alter the number of rows per page on the console display. Operator modify parameter description example switch_prompt # modify rows rows(18): 25 there are now 25 rows per page switch_prompt # server svc x x input paramet...

  • Page 188

    2-164 smartcell 6a000/zx-250 reference manual console commands sarstat use sarstat (segmentation and reassembly statistics) to view statistics from the sar on the cpu port. This is useful for debugging hardware problems. Operator show parameters this command has no input parameters. Just type show s...

  • Page 189

    Smartcell 6a000/zx-250 reference manual 2-165 console commands description [isr int] total interrupts received. [rqu int] receive queue underrun indicator since last up-time or clear. [rqa int] receive queue alert indicator since last up-time or clear. [mm int] mailbox modified indicator. [mf int] m...

  • Page 190

    2-166 smartcell 6a000/zx-250 reference manual console commands example switch_prompt # show sarstat receive statistics rcv pkts: 6 rcv byts: 648 raw cell: 0 buf uf : 0 fifo or : 0 max len : 0 len err : 0 crc err : 7 u abrts : 0 t1 err : 0 chnl dvt: 26 spur int: 0 ttal err: 7 isr int: 39 rqu int: 0 r...

  • Page 191

    Smartcell 6a000/zx-250 reference manual 2-167 console commands shutdown use shutdown to shut down the switch to a state where it can be powered off. It stops all logging and synchronizes the file system. This must be run before turning off the switch. Operator shutdown parameters this command has no...

  • Page 192

    2-168 smartcell 6a000/zx-250 reference manual console commands sigconfig use sigconfig (signaling configuration) to manage signaling configuration of all or specific ports. Operators modify, show parameters server svc x x input parameter description value/field size default [portnumber] port number ...

  • Page 193

    Smartcell 6a000/zx-250 reference manual 2-169 console commands descriptions examples switch_prompt # modify sigconfig portnumber(a1) : a2 currentinterfacetype(uni3.0) : uni3.1 currentinterfacerole(network) : user defaultinterfacetype(uni3.0) : uni3.1 defaultinterfacerole(network) : user switch_promp...

  • Page 194

    2-170 smartcell 6a000/zx-250 reference manual console commands the following examples are for a specific port - a2, and then for all ports: switch_prompt # show sigconfig a2 portnumber : a2 current signaling type : uni3.1 current signaling role : network default signaling type : uni3.1 default signa...

  • Page 195

    Smartcell 6a000/zx-250 reference manual 2-171 console commands sigflags use sigflags (signaling flags) to view the status of flags related to signaling. This command is unmodifiable, and the switch defaults to a uni3.1 to uni3.0 translation. Operator show parameter description example switch_prompt ...

  • Page 196

    2-172 smartcell 6a000/zx-250 reference manual console commands sigstat use sigstat (signaling statistics) to see current signaling statistics of all ports or a specific port. Operator show parameters server svc x x input parameter description value/field size default [portnumber] port number on the ...

  • Page 197

    Smartcell 6a000/zx-250 reference manual 2-173 console commands description [emit signaling message errors] number of signaling message errors for this switch (such as invalid information elements (ie) or missing mandatory elements in the ies). [detect timer expirations] number of calls terminated by...

  • Page 198

    2-174 smartcell 6a000/zx-250 reference manual console commands example switch_prompt # show sigstat portnumber(all) : a2 signaling per port statistics =========================================================================== port# : a2 detect unavailable routes : 0 emitt unavailable routes : 0 det...

  • Page 199

    Smartcell 6a000/zx-250 reference manual 2-175 console commands sscopconfig use sscopconfig (service-specific connection-oriented protocol configuration) to view timers and other parameter values. Operator show parameters server svc x x parameter description value/field size default [port#] port numb...

  • Page 200

    2-176 smartcell 6a000/zx-250 reference manual console commands description examples switch_prompt # show sscopconfig portnumber(all) : a1 port# maxpd maxcc polltm kpalivetm noresptm cctm txwindowsz rxwindowsz =========================================================================== a1 15 5 250 150...

  • Page 201

    Smartcell 6a000/zx-250 reference manual 2-177 console commands svc use svc (switched virtual circuit) to see the svcs created on the switch. Operator show parameters in the output parameter table below, ( /d >) appears next to parameters that are available only through the show svc /d (detailed) com...

  • Page 202

    2-178 smartcell 6a000/zx-250 reference manual console commands [conntype] ( /s >) either pmp to ptp connection type. Pmp, ptp [lowport] ( /s >) [lowvpi] ( /s >) [lowvci] ( /s >) [highport] ( /s >) [highvpi] ( /s >) [highvci] ( /s >) these parameters are available in the show svc /s option, as well a...

  • Page 203

    Smartcell 6a000/zx-250 reference manual 2-179 console commands [fwdrmcellpriority] ( /d >) forward rm (resource management) cell priority for this cross-connect, as calculated by cac. Enabled, disabled fwd cell loss priority (clp)] ( /d >) forward bandwidth allocated to this cross-connect, as calcul...

  • Page 204

    2-180 smartcell 6a000/zx-250 reference manual console commands descriptions examples the following examples show a summarized and detailed listing of an svc. Summarized report () switch_prompt # show svc /s portnumber(all) : crossconnectid(all) : conn conn traffic conn low high admin id subid type t...

  • Page 205

    Smartcell 6a000/zx-250 reference manual 2-181 console commands detailed report ( ) switch_prompt # show svc /d portnumber(all) : crossconnectid(all) : show cross-connection in detailed mode ============================================================================ cross-connect id : 4654 connectio...

  • Page 206

    2-182 smartcell 6a000/zx-250 reference manual console commands switch use switch to backup and restore switch configuration files. Operators backup, restore parameters server svc x x input parameter description value/field size default [serverip] ip address of the backup server. Dot decimal/ 7-15 ch...

  • Page 207

    Smartcell 6a000/zx-250 reference manual 2-183 console commands descriptions examples switch_prompt # backup switch serverip(1.1.1.200) : 1.1.1.200 path(public/smartcell.Ztr) : /back_dir/cnfg_wk04 switch_prompt # switch_prompt # restore switch serverip() : 1.1.1.200 path(/back_dir/cnfg_wk04) : backup...

  • Page 208

    2-184 smartcell 6a000/zx-250 reference manual console commands switchconfig use switchconfig (switch configuration) to manage switch-related parameters, like switchname and ip address. Operators modify, show parameters server svc x x input parameter description value/field size default [switchname] ...

  • Page 209

    Smartcell 6a000/zx-250 reference manual 2-185 console commands [common dram] common dram memory size. Megabytes/up to 4 characters [sar control sram] sar control memory size. Kilobytes/up to 5 characters power mode type of power modules used by the switch redundant, non-redundant [number of switch b...

  • Page 210

    2-186 smartcell 6a000/zx-250 reference manual console commands [build date] the date which the code was loaded on the switch. Day/month/date/ hr:min:sec year [software image size] binary image size. Bytes [heap space used/total/%free] total heap space used, total memory allocated to heap, and percen...

  • Page 211

    Smartcell 6a000/zx-250 reference manual 2-187 console commands descriptions examples switch_prompt # modify switchconfig switchname(switch_1) : switch_2 ipaddress(200.30.72.122) : 1.1.1.202 ipnetmask(255.255.255.0) : 255.255.255.128 switch_prompt # switch_prompt # show switchconfig switch configurat...

  • Page 212

    2-188 smartcell 6a000/zx-250 reference manual console commands switchname use switchname to change the name of the switch. Operator modify parameter description example switch_prompt # modify switchname switchname(switch_1): switch_2 confirm(y/n)?: y switch_prompt # server svc x x input parameter de...

  • Page 213

    Smartcell 6a000/zx-250 reference manual 2-189 console commands switchtrafficcongestion use switchtrafficcongestion to manage global switch traffic congestion thresholds on the switch. Operators modify, show parameters server svc x x parameter description value/field size default [queue # efci thresh...

  • Page 214

    2-190 smartcell 6a000/zx-250 reference manual console commands descriptions examples switch_prompt # modify switchtrafficcongestion queue1efcithreshold(16383) : 2000 queue2efcithreshold(16383) : 2000 queue3efcithreshold(16383) : 2000 queue4efcithreshold(16383) : 2000 lowepdwatermark(7552) : 4000 hig...

  • Page 215

    Smartcell 6a000/zx-250 reference manual 2-191 console commands trafficdescriptor use trafficdescriptor to manage the templates that describe traffic characteristics of a vc (virtual circuit) that are used in the creation of pvcs (permanent virtual circuits. A traffic descriptor is a list of paramete...

  • Page 216

    2-192 smartcell 6a000/zx-250 reference manual console commands [scrclp0] specifies maximum average rate at which cells can be sent over a vc. Scr of cells with their clp bit equals zero. Kb/s/ 0-622000 0 [mbsclp01] mbs (maximum burst size) of cells with their clp set to one. Specifies the maximum nu...

  • Page 217

    Smartcell 6a000/zx-250 reference manual 2-193 console commands descriptions examples the following example creates a traffic descriptor of type 4. After the traffic descriptor is created, it is listed in a table and associated with an index number. Although the index numbers are defined sequentially...

  • Page 218

    2-194 smartcell 6a000/zx-250 reference manual console commands switch_prompt # add trafficdescriptor traffictype(ubr) : cbr trafficdescriptortype(8) : 4 pcrclp01(0) : 180 pcrclp0(0) : 155 scrclp01(0) : scrclp0(0) : mbsclp01(0) : mbsclp0(0) : qosclass(1) : aaltype(5) : 1 switch_prompt # switch_prompt...

  • Page 219

    Smartcell 6a000/zx-250 reference manual 2-195 console commands 4 -with clp and tagging, but no scr. Cbr, nrtvbr, rtvbr pcrclp0, pcrclp01 1 evaluates cells set with clp=1 and cells set with clp=0 separately. Because tag option is set, non-compliant clp=0 cells are tagged and non-compliant clp=1 cells...

  • Page 220

    2-196 smartcell 6a000/zx-250 reference manual console commands.

  • Page 221

    Smartcell 6a000/zx-250 reference manual 2-197 console commands trapcommunity use trapcommunity to manage the list of hosts that the switch sends trap notifications to concerning significant events. Each trap community has a name, ip address, and port number. The trap community name and address combi...

  • Page 222

    2-198 smartcell 6a000/zx-250 reference manual console commands descriptions examples switch_prompt # add trapcommunity name() : boris ipaddr() : 204.95.77.148 port (162) : 100 switch_prompt # switch_prompt # show trapcommunity trapcommunity name ip address port ======================================...

  • Page 223

    Smartcell 6a000/zx-250 reference manual 2-199 console commands trustednms use trustednms (trusted network management system) to configure a “trusted network management system” on the switch. The trusted nms is identified by its ip address. Only the trusted network management system is allowed to per...

  • Page 224

    2-200 smartcell 6a000/zx-250 reference manual console commands parameters descriptions examples switch_prompt # modify trustednms ipaddr() : 90.1.1.1 trusted nms ip-address : 90.1.1.1 switch_prompt # switch_prompt # show trustednms trusted nms ip-address : 90.1.1. Switch_prompt # input parameter des...

  • Page 225

    Smartcell 6a000/zx-250 reference manual 2-201 console commands uniroute use uniroute (user-network interface route) to manage uni routes and uni routing tables. The routes are static using this command, compared to the dynamic uni routes created through ilmi registration. Operators add, delete, show...

  • Page 226

    2-202 smartcell 6a000/zx-250 reference manual console commands examples switch_prompt # add uniroute portnumber(a1) : a3 uniatmaddress():39:00:00:00:00:00:00:11:22:33:44:55:66:11:22:33:44:55:66:01 switch_prompt # add uniroute portnumber(a1) : a3 uniatmaddress():39:00:00:00:00:00:00:00:20:d4:14:15:00...

  • Page 227

    Smartcell 6a000/zx-250 reference manual 2-203 console commands the following example shows the uniroute listing, before and after all ports are flushed: switch_prompt # show uniroute portnumber(all): port# routetype atm address ========================================================================...

  • Page 228

    2-204 smartcell 6a000/zx-250 reference manual console commands vccmask use vccmask (virtual channel connection mask) to manage the combination of vpi (virtual path identifier) bit and vci (virtual channel identifier) bit settings. There are only four different vcc mask entries allowed by the switch ...

  • Page 229

    Smartcell 6a000/zx-250 reference manual 2-205 console commands examples switch_prompt # modify vccmask maskindex(0) : 0 vpishift(0) : 3 vcishift(12) : 9 switch_prompt # switch_prompt # show vccmask maskindex vpishift vcishift (in bits) (in bits) ======================================================...

  • Page 230

    2-206 smartcell 6a000/zx-250 reference manual console commands wellknownaddress use wellknownaddress to manage the mapping between the atm forum defined well-known address for the lecs (lan emulation configuration server) and a registered address for another lecs. Operators add, delete, show, flush ...

  • Page 231

    Smartcell 6a000/zx-250 reference manual 2-207 console commands descriptions operator parameters/permissions description add wellknownaddress [wellknownaddress] clientatmaddress> [registeredaddress] serveratmaddress> administrator maps well-known address to the registered address of the server. This ...

  • Page 232

    2-208 smartcell 6a000/zx-250 reference manual console commands examples switch_prompt # add wellknownaddress wellknownaddress(47:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01:00): registeredaddress(39:00:00:00:00:00:00:00:20:d4:14:22:80:00:20:d4:14:22:80:01): 10.20.30.40.50 switch_prompt # s...

  • Page 233

    Smartcell 6a000/zx-250 reference manual 3-1 boot load commands 3 boot load commands this chapter describes the low-level boot load commands. Boot load commands are used for setting switch start-up behavior and for performing software downloads. Use the boot load commands to: • set which copy of the ...

  • Page 234

    3-2 smartcell 6a000/zx-250 reference manual boot load commands accessing the boot load commands boot load commands are executed from the boot load prompt. The boot load prompt is not part of the switch console, and is accessible only after a reboot and before the switch software is loaded. Perform t...

  • Page 235

    Smartcell 6a000/zx-250 reference manual 3-3 boot load commands chpi use chpi to set one of the two boot load software images as the default. Unless otherwise specified within the initial reboot countdown, the default boot load software image is the image that is loaded into dram and executed. Exampl...

  • Page 236

    3-4 smartcell 6a000/zx-250 reference manual boot load commands clfs use clfs to clear the switch flash file system. The clfs command clears all vlan and elan configurations, route definitions, port settings, and pvc configurations. Clfs also clears all ip addresses, including the ip address for the ...

  • Page 237

    Smartcell 6a000/zx-250 reference manual 3-5 boot load commands dcfg use dcfg to display information about the current boot prom configuration • revision numbers of both boot load software images • display the switch mac address • number (in hexadecimal) of contiguous mac addresses after the base mac...

  • Page 238

    3-6 smartcell 6a000/zx-250 reference manual boot load commands df use df (download firmware) to download software images from a tftp/bootp server to the flash ram of the switch. The df command uses three parameters: b , s , and p . These parameters specify which software component to download. Examp...

  • Page 239

    Smartcell 6a000/zx-250 reference manual 3-7 boot load commands go use the go command to exit the boot load prompt and run switch software (with or without post). Example =>go s verifying checksum of secondary flash... Host name: attaching network interface ei0... Done. Attaching network interface lo...

  • Page 240

    3-8 smartcell 6a000/zx-250 reference manual boot load commands he use he to get help on boot load commands or show list of all boot load commands. The question mark ( ? ) can be entered in place of he . Example =>he chpi chpi [option] option: 0 ..Changes the boot load default to be boot load softwar...

  • Page 241

    Smartcell 6a000/zx-250 reference manual 3-9 boot load commands ponf use ponf to set whether post diagnostics are run by default when the switch is started. Example =>ponf p modifying control/stat field to execute post, please wait... New postonoff value programmed successfully into control/stat fiel...

  • Page 242

    3-10 smartcell 6a000/zx-250 reference manual boot load commands.

  • Page 243

    Smartcell 6a000/zx-250 reference manual a-1 appendix a acronyms a b aal atm adaptation layer aal1 atm adaptation layer type 1 aal2 atm adapter layer type 2 aal3/4 atm adapter layer type 3/4 aal5 atm adapter layer type 5 aalm atm adaptation layer mux abr available bit rate afi authority and format id...

  • Page 244

    A-2 smartcell 6a000/zx-250 reference manual acronyms c bus broadcast and unknown server cac call admission control can campus area network cat-3 category 3 unshielded twisted pair cable cat-5 category 5 unshielded twisted pair cable cbr constant bit rate ccitt comite consultatif internationale de te...

  • Page 245

    Smartcell 6a000/zx-250 reference manual a-3 acronyms d e dcc digital cross connect, generic dacs or direct connect card, data interface module df download flash ds-0 digital signaling 0 ds-1 digital signaling 1 ds-3 digital signaling 3 dte data terminal equipment dvt delay variation tolerance e-1 eu...

  • Page 246

    A-4 smartcell 6a000/zx-250 reference manual acronyms f g h i fcs frame check sequence fifo first in first out ftp file transfer protocol gb/s gigabits per second gcra generic cell rate algorithm gfc generic flow control hec header error check ieee institute of electrical and electronic engineers icm...

  • Page 247

    Smartcell 6a000/zx-250 reference manual a-5 acronyms j k l i/o input/output iom input/output module ip internet protocol ip/atm internet protocol over atm ipx internetwork packet exchange protocol itu-tss international telecommunications union-telecommunications standards sector isdn integrated serv...

  • Page 248

    A-6 smartcell 6a000/zx-250 reference manual acronyms m n lecsela n lan emulation configuration server emulated lan les lane server leselan lane server emulated lan lis logical ip subnetwork llc logical link control lmi local management interface mac media access control man metropolitan area network...

  • Page 249

    Smartcell 6a000/zx-250 reference manual a-7 acronyms o p netbeui netbios extension user interface nfs network file system nic network interface controller/card nls natural language syntax nms network management system nni network node interface or network-to-network interface nrt-vbr non real time -...

  • Page 250

    A-8 smartcell 6a000/zx-250 reference manual acronyms q r pdu protocol data unit pmd physical media dependent sub-layer pmp point-to-multipoint p-nni private network node interface or private network-to-network interface ppd partial packet discard prom programmable read-only memory pti payload type i...

  • Page 251

    Smartcell 6a000/zx-250 reference manual a-9 acronyms s rt-vbr real time - variable bit rate rw read-write access saal signaling atm adaptation layer sar segmentation and reassembly sar-pdu sar protocol data unit sbe system bus error scr sustainable cell rate sdh synchronous digital hierarchy seal si...

  • Page 252

    A-10 smartcell 6a000/zx-250 reference manual acronyms t u v t-1 transmission system 1 t-3 transmission system 3 taxi transparent asynchronous transmitter/receiver interface tcp transmission control protocol td traffic descriptor tdm time-division multiplexing tftp trivial file transfer protocol tlv ...

  • Page 253

    Smartcell 6a000/zx-250 reference manual a-11 acronyms w vcc virtual channel connection vci virtual channel identifier vcl virtual channel link vlan virtual lan vp virtual path vpc virtual path connection vpi virtual path identifier vpn virtual private network vt virtual tributary wan wide area netwo...

  • Page 254

    A-12 smartcell 6a000/zx-250 reference manual acronyms.

  • Page 255

    Smartcell 6a000/zx-250 reference manual b-1 appendix b cause codes atm events often generate messages that appear on the console. Most messages are self-explanatory. However, some messages contain additional information in the form of cause codes. These codes identify the cause of the event. For exa...

  • Page 256

    B-2 smartcell 6a000/zx-250 reference manual cause codes 38 network out of order 41 temporary failure 43 access information discarded 45 no vpi/vci available 47 resource unavailable, unspecified 49 quality of service unavailable 51 user cell rate unavailable 57 bearer capability not authorized 58 bea...

  • Page 257

    Smartcell 6a000/zx-250 reference manual b-3 cause codes 115 no response to restart request 116 link not active 117 link not found 118 calling party number not set. 119 call control block not found 120 internal resource error 121 sap not active table b-1 cause code values and meanings cause code mean...

  • Page 258

    B-4 smartcell 6a000/zx-250 reference manual cause codes.

  • Page 259

    Smartcell 6a000/zx-250 reference manual c-1 appendix c technical support this appendix tells you what to do if you need technical support for your smartcell zx-250 switch. Cabletron offers several support and service programs that provide high-quality support to our customers. For technical support,...

  • Page 260

    C-2 smartcell 6a000/zx-250 reference manual technical support detailed description of the issue (including history, what you've tried, and conditions under which you see this occur) hardware model number, software version, and switch configuration (that is, what part types are in what slots) hardwar...

  • Page 261

    Smartcell 6a000/zx-250 reference manual i-1 index a aaltype ............................................. 2-192 abbreviations ........................................... 1-3 access denied ........................................ 2-79 accessing boot load commands ................ 3-2 accessing the bo...

  • Page 262

    I-2 smartcell 6a000/zx-250 reference manual index c cacparams switch attribute ..... 2-20 to 2-21 cacstat switch attribute ........... 2-22 to 2-23 cause codes aal parameters cannot be supported ........................................... B-2 access information discarded ........... B-2 bearer capab...

  • Page 263

    Smartcell 6a000/zx-250 reference manual i-3 index controltimeout ...................................... 2-83 conventions .............................................. 1-2 count .................................................... 2-129 cpe int ................................................. 2-165...

  • Page 264

    I-4 smartcell 6a000/zx-250 reference manual index f fifo or ............................................... 2-164 filter debug lvl ................................... 2-112 filter flags ............................................ 2-113 filter messageid ................................... 2-111 filt...

  • Page 265

    Smartcell 6a000/zx-250 reference manual i-5 index l2hopstatus ........................................ 2-178 lan name ....................................2-24, 2-66 lan type ........................... 2-25 , 2-42 , 2-95 lec configs ........................................... 2-79 lecaddress ..........

  • Page 266

    I-6 smartcell 6a000/zx-250 reference manual index out octets ............................................... 2-18 out unicast ............................................. 2-18 output destination ............................... 2-112 output type .......................................... 2-111 p par...

  • Page 267

    Smartcell 6a000/zx-250 reference manual i-7 index spe int ................................................. 2-165 spur int ................................................. 2-164 start record ........................................... 2-113 startfilenum ............................................ ...

  • Page 268

    I-8 smartcell 6a000/zx-250 reference manual index.