CAC / BDP BGEFU1 Service Manual - page 4
4
ACCESSING THE SERVICE
FUNCTIONS
In order to access the service functions, after installing the batteries,
during the first 30 seconds, press and hold MODE, FAN, and
TIME ON together for 5 seconds. The remote controller resets
and the LCD window displays “F1”. Use the service functions
(F1) menu to configure the remote controller’s functions to
personalize the unit’s use.
ON/OFF
TEMP
FP
TIMER
ON
TIMER
OFF
MODE
FAN/SLC
SLEEP
SWING
DIRECT
TURBO
CLEAN
LED
FOLLOW
Fig. 5 – Remote Controller
IMPORTANT: The remote controller is enabled within 10
minutes after the indoor unit is powered on, and the indoor
unit must be turned off.
ON/OFF
POWER OFF: Press to turn off the unit
Fig. 6 – Power Off
MODE
MODE: Use to modifythe selected function.
Press MODE to enter the parameter setting
interface, and the selected parameter indicator
will flash. Use TEMP ▲ and ▼to modify the
parameter or select another parameter in
conjunction with FAN and TIMER OFF.
Fig. 7 – Mode
TEMP
TEMP ▲ and ▼: Use to select fuctions or
adjust parameters. On the parameter
unadjustable interface, press ▲ and ▼to
select the specified function in a range of
F1~F9 and E1~E9. Next, press MODE to
enter the parameter modifying interface and
the relevant parameter flashes. Press
▲ and ▼to adjust the parameter.
Fig. 8 – Temp
TIMER ON
TIMER ON: Press to confirm the setting parameter
and transmit the signal to the unit.
Fig. 9 – Timer ON
TIMER OFF
FAN & TIMER: On the parameter setting
interface, press FAN and TIMER OFF to
select the parameter to modify.
FAN
Fig. 10 – Fan and Timer
LOCK: Press and hold SLEEP and DIRECT for
2 seconds, all the indoor unit’s current settings
are locked in and the remote controller will not
accept any operation other than the LOCK
operation.
SLEEP
DIRECT
Fig. 11 – Lock
REMOTE CONTROLLER SERVICE
FUNCTIONS
NOTE: The indoor unit beeps for 2 seconds indicating the
function has been successfully set.
Auto−Start Function (F1)
In case of a sudden power failure, the module memorizes the
setting conditions before the power failure. The unit resumes the
previous operation setting automatically after 3 minutes when the
power returns. In order to enable/disable this function:
1. Press
▲
and
▼
to select “F1”.
Fig. 12 – Select F1
2. Press MODE. Next, press
▲
and
▼
to select “ON” or
“OFF”.
MODE
Fig. 13 – Select On or Off
3. Press TIMER ON and the Auto−start function setting is
complete.
TIMER ON
Fig. 14 – TIMER ON
Heating Temperature Compensation (F2)
Defines the adjustment for the thermal stratification in the room
and how the indoor unit is sensing the space. To adjust the
temperature compensation, in Celsius only:
NOTE: The temperature compensation in Celsius regardless of the
units used.
1. Press
▲
and
▼
to select “F2”.
Fig. 15 – Select F2
2. Press MODE. Next, press
▲
and
▼
to select the parameter
(range: −6
_
C ~ 6
_
C).
MODE
-
-
-
-
-
-
....
....
....
....
Fig. 16 – Select the parameter
3. Press TIMER ON to confirm.
TIMER ON
Fig. 17 – Timer On
NOTE: The recommended setting is 0
_
C. The adjustment should
not be more than 2
_
C.