Caen A3484 Technical Information Manual - page 18
Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
A3484-A3485 AC/DC Converter 400 V 3-phase 48 V 2.5/5kW
04/07/2017
3
NPO:
Filename:
Number of pages:
Page:
00120/04:A348x.MUTx/03
A3485_REV3.DOC
21
18
A read access to the 12VPwS#CoClose
item returns back the label “On” associated to
12VPwS=OK.
A read access to the StatusIn item returns the StatusIn connector signal.
A read access to the StatusIn#CoOpen item returns back the lab
el “Off” associated to
StatusIn = FAIL.
A read access to the StatusIn#CoClose
item returns back the label “On” associated to
StatusIn = OK.
A read access to the Sync item returns the external 50 Hz status.
A read access to the Sync#CoOpen item returns back
the label “Off” associated to
Sync=FAIL.
A read access to the Sync#CoClose
item returns back the label “On” associated to
Sync=OK.
A read access to the HVSync item returns the external 625 Hz status.
A read access to the HVSync#CoOpen item returns back th
e label “Off” associated to
HVSync=FAIL.
A read access to the HVSync#CoClose
item returns back the label “On” associated to
HVSync=OK.
A read access to the RemBdName item returns a string with the board name.
Table 4.4 – Internal Channel items
ItemID
Data Type
Access
Description
PowerSupplyName.BoardXX.ChanYYY.Name
String
R/W
Channel name
PowerSupplyName.BoardXX.Chan0.SerNum
2-byte int.
R
Board serial number
PowerSupplyName.BoardXX.Chan0.Rel
String
R
Board firmware release
PowerSupplyName.BoardXX.Chan0.12VPwS
boolean
R
12VPS status
PowerSupplyName.BoardXX.Chan0.12VPwS#CoOpen
string
R
12VPS open label
PowerSupplyName.BoardXX.Chan0.12VPwS#CoClose
string
R
12VPS close label
PowerSupplyName.BoardXX.Chan0.StatusIn
boolean
R
StatusIn status
PowerSupplyName.BoardXX.Chan0.StatusIn#CoOpen
string
R
StatusIn open label
PowerSupplyName.BoardXX.Chan0.StatusIn#CoClose
string
R
StatusIn close label
PowerSupplyName.BoardXX.Chan0.Sync
boolean
R
Sync status
PowerSupplyName.BoardXX.Chan0.Sync#CoOpen
string
R
Sync open label
PowerSupplyName.BoardXX.Chan0.Sync#CoClose
string
R
Sync close label
PowerSupplyName.BoardXX.Chan0.HVSync
boolean
R
HVSync status
PowerSupplyName.BoardXX.Chan0.HVSync#CoOpen
string
R
HVSync open label
PowerSupplyName.BoardXX.Chan0.HVSync#CoClose
string
R
HVSync close label
PowerSupplyName.BoardXX.Chan0.RemBdName
string
R
Board name
4.1.2
Output Channel OPC Items
This chapter describes the items which are available for the control of the power supply
channels.
The Name item allows to assign to the channel a symbolic name.
The V0set item allows to set V0.
A read access to the V0set#EU item returns a string with the V0set Engineering Units.