Caen A3484 Technical Information Manual - page 19
Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
A3484-A3485 AC/DC Converter 400 V 3-phase 48 V 2.5/5kW
04/07/2017
3
NPO:
Filename:
Number of pages:
Page:
00120/04:A348x.MUTx/03
A3485_REV3.DOC
21
19
A read access to the V0set#HighEU item returns the highest possible V0set value.
A read access to the V0set#LowEU item returns the lowest possible V0set value.
The I0set item allows to set I0.
A read access to the I0set#EU item returns a string with the I0set Engineering Units.
A read access to the I0set#HighEU item returns the highest possible I0set value.
A read access to the I0set#LowEU item returns the lowest possible I0set value.
The Trip item allows to program the trip time.
A read access to the Trip#EU item returns a string with the Trip Engineering Units.
A read access to the Trip#HighEU item returns the highest possible Trip value.
A read access to the Trip#LowEU item returns the lowest possible Trip value.
The SVMax item allows to set the software voltage limit.
A read access to the SVMax#EU item returns a string with the SVMax Engineering Units.
A read access to the SVMax#HighEU item returns the highest possible SVMax value.
A read access to the SVMax#LowEU item returns the lowest possible SVMax value.
The VMon item returns back the VMon value.
A read access to the VMon#EU item returns a string with the VMon Engineering Units.
A read access to the VMon#HighEU item returns the highest possible VMon value.
A read access to the VMon#LowEU item returns the lowest possible VMon value.
The VCon item returns back the VCon value.
A read access to the VCon#EU item returns a string with the VCon Engineering Units.
A read access to the VCon#HighEU item returns the highest possible VCon value.
A read access to the VCon#LowEU item returns the lowest possible VCon value.
The IMon item returns back the IMon value.
A read access to the IMon#EU item returns a string with the IMon Engineering Units.
A read access to the IMon#HighEU item returns the highest possible IMon value.
A read access to the IMon#LowEU item returns the lowest possible IMon value.
The Temp item returns back the channel temperature.
A read access to the Temp#EU item returns a string with the Temp Engineering Units.
A read access to the Temp#HighEU item returns the highest possible Temp value.
A read access to the Temp#LowEU item returns the lowest possible Temp value.
A read access to the Status item returns back a 16 bit pattern indicating channel status,
as follows:
Bit 0: ON/OFF
Bit 1: don’t care
Bit 2: don’t care
Bit 3: OverCurrent
Bit 4: OverVoltage
Bit 5: UnderVoltage
Bit 6: don’t care
Bit 7: Over HVmax
Bit 8: don’t care
Bit 9: Internal Trip
Bit 10: Calibration Error
Bit 11: don’t care
Bit 12: don’t care
Bit 13: OverVoltage Protection
Bit 14: Power Fail
Bit 15: Temperature Error
The RemIlk item returns back the Remote Interlock value.