Calibre UK VideoExcel Operating Instructions Manual - page 26
© Calibre UK Limited Issue 4.00 22
nd
January 2014, W: www.calibreuk.com
Page 26
T:+44 1274 394125 F: +44 1274 730960 E:
techsupport@calibreuk.com
,
Component Format (Component only)
For analog Component Video inputs only, select whether the input source provides YPbPr, YPbPrS,
RGB or RGBS video. It is also possible to choose between 0.7v and 1.0v video levels on the component
inputs. Most sources provide 0.7v video, plus 0.3v sync, but some do provide 1.0v (excluding syncs).
Incorrect format selection will cause severe color errors or loss of stable picture, incorrect level selection
will cause the picture be very dim, or cause peak whites to be compressed.
Channel Reset
The configuration for an input channel can be removed by performing a channel reset.
3GSDI Level B Stream (3GSDI only)
When input is 3G Level B (2 stream mapping), there is an option to select which of the two video
streams (Stream 1 or 2) to use. Otherwise it works with whatever mapping is specified in the SMPTE
352 packet (or defaults to 10bit 4:2:2 if none).
Select Test Pattern (Default)
When Test Pattern is selected as the input channel the default test pattern can be selected here.
HDMI Audio Input
Allows the user to set the format of the HDMI audio channel. Use to choose how many channels of
audio are requested from the HDMI source equipment.
Audio Delay
The audio delay is automatically set to compensate for the latency through the unit. The Audio Delay
adjustment does not override this automatic setting but allows fine calibration of the audio delay in steps
of approximately 1mS, to advance or retard the audio so as to compensate for further delays in your
display device or your audio system.
4.9.5.
No Sync Color
Defines the output background color when no valid input signal is detected on the current selected input.
Options are Blue, White, Orange and Black. Default is Black.
4.9.6.
Factory Reset
Factory reset puts all settings in the unit back to factory defaults. Note: A factory reset can also be
issued at power up (or reset) by pressing the up arrow of the keypad. The up arrow key needs to be
kept pressed until the “Resetting to factory defaults ...” message is shown.
4.9.7.
Unit Configuration
Menu Timeout
Sets the time for the front panel to go back from displaying the current menu to display the top level
menu
Front Panel Backlight
Sets the brightness of the front panel backlight
Power Inlet Monitoring
Determines whether the power inlets are monitored. When the inlets are monitored a failing inlet is
indicated by a message and a flashing LCD menu.
Enable Automatic Keypad Lockout
By default the keypad is locked. It can always be unlocked by pressing the sequence of Enter and Input
key. Once a button is pressed this key sequence is identified with a message. The keypad unlocking is
timed out after 15 seconds of not continuing pressing keys. This time out can be disabled here.
4.9.8.
Networking(TCP/IP)
The IP address type (static or DHCP), static IP address, default gateway IP address, subnet mask and
extended network prefix can all be entered here.