CALORIQUE BEL100 Installation Manual - page 3
www.calorique.com
3 |
P a g e
The heating output will be switched
off and will be displayed if the floor temperature limit is exceeded.
Enable Keylock:
The Calorique Bell 100 thermostat has a key-lock facility.
To enable, press the F and UP arrow keys for 10 seconds. When the key-lock has been activated, you will see
on screen.
To cancel, repeat the steps above.
Changing Feature Setup:
With Calorique’s Bel 100 Thermostat turned off, press
for 3 seconds.
Press the
button until the small number (menu setting from 07 to 09) in the top left hand corner is set to
the required value (See Figure 1 below).
Use the Up/Down arrow key to change the large number (parameter setting) as required.
Press
to accept and proceed to the next menu.
Press
to store and exit.
Menu
Meaning
Parameter
07
Floor Limit
(only for mode 01)
00 = disable
01 = enable
(default = 01)
08
Floor Maximum limit
(only for mode 01)
20 - 45°C(28°C default)
09
Mode Selection
00 &01
(default = 01)
Figure 1: Menu Settings and Parameters
UNDER ANY SETTING MODE, IF NO BUTTON IS PRESSED FOR 30 SECONDS, THE BELL 100 THERMOSTAT WILL
EXIT THE FEATURE AND SAVE THE SETTING.
THE BACKLIGHT FEATURE WILL TURN OFF IF NO BUTTON IS PRESSED
Wiring Diagram:
WALL
L
LOAD
N
N
_
R
THERMOSTAT( REAR VIEW )
Cablemat
SENSOR
SensorCable
ELECTRIC CABLEMAT
Cable
FLOOR
Fig.2 Schematic Diagram
L
N
●
●
ELECTRICAL
PANE
Power Cable
230V AC