CAME BK 1200 Installation Manual - page 13
1 ON - Automatic Closing – the automatic closing timer is automatically triggered at the end of the opening phase. The
adjustable set time of operation, is in any case subordinate to the operation of any safety accessories and is exclu-
ded after a total “stop” phase or if the main power is cut off.
2 ON - “Open-stop-close-stop” function with button (2-7) and remote control (that has a radio frequency board inserted).
2 OFF - “Open-close-inversion” function with button (2-7) and remote control (that has a radio frequency board inserted).
3 ON - “Open only” remote control (that has a radio frequency board inserted).
4 ON - “Maintained action” function” – Gate operation by keeping the opening button pressed on 2-3, and the closing
button 2-4, (it excludes the remote control from operating).
5 ON - Pre-flashing in opening and closing phase – Following a command to open or close, the flashing device connected
to W-E1, flashes for 5 seconds before gate movement begins.
6 ON - Obstacle sensor – When the motor is not running (i.e. the gate is closed, open or following a total stop command),
it prevents any movement of the gate if the safety devices (e.g. the photocells) sense and obstacle in the way.
7 OFF - Reopening during the closing phase – When the photocells sense and obstacle as the arm is closing, they trigger
an inversion of direction movement until full opening is achieved; insert the safety device into terminal (2-C1); if
not used, set dip switch to ON.
8 OFF / 9 OFF – Re-closing during opening phase – When the photocells sense an obstacle in the way during the gate’s
opening phase, they trigger an inversion of movement direction until the gate is fully closed; insert safety device
into terminal (2-CX);
8 OFF / 9 ON – Partial stop – The gate stops completely when moving consequently triggering the automatic closing, insert
the safety device into terminal (2-CX); (if the devices on 2-CX are not used, set dip switch 8 to the ON position)
10 OFF- Total stop – This function stops the gate and consequently excludes any automatic closing phase; for movement to
begin again press button or remote control. Insert the safety device into (1-2); if not used, set dip switch to the ON
position.
ON
OFF
6.7 Selecting functions (dip-switch)
11 OFF - “Slave” function deactivated, the board is exclusively piloted by the “master” (to be activated only for coupled
connection, see p.15);
12 ON - Partial opening function (the automatic closing is fixed to 8”);
12 OFF - Partial opening function (the automatic closing is adjustable through the trimmer, if inserted);
13 ON - Functioning of the photocells’ safety test – Enables the control unit to test the efficiency of the safety devices (e.g.
photocells) after each opening or closing command;
14 OFF - “Master” function deactivated, the board takes over all the control functions as concerns two coupled motors (to
be activated only for coupled connection, p. 15);
15 ON - “Spare” function for programming the limit switch (only for the ZBKE series, p. 14);
16 ON /17 OFF - Courtesy lamp function activated; (16 OFF deactivated)
17 ON / 16 OFF - Phase lamp function activated; (17 OFF deactivated)
18
Not connected
19
Not connected
20
Not connected
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
ON
ON
13
A
ll t
h
e d
at
a a
n
d i
n
fo
rm
at
io
n c
o
n
ta
in
ed h
er
ei
n
i
s c
o
n
si
d
er
ed
s
u
b
je
ct to c
h
an
g
e a
t a
n
y t
im
e a
n
d a
t o
u
r d
is
cr
et
io
n
ENGLISH