CAME FA40230 Installation manual - page 28
F
i
ENTER
>
>
ENTER
>
>
>...>
0
0
I
i
F
i
2
F
i
ENTER
>
>
ENTER
>
>
>...>
i
F
0
2
I
0
8
2
F
i
ENTER
>
>
ENTER
>
>
>...>
F
9
i
0
i
I
0
8
F
i
ENTER
>
>
ENTER
>
>
>...>
F
2
2
I
0
2
5
6
F
i
ENTER
>
>
ENTER
>
>
>...>
F
3
2
0
0
I
i
F
i
0
F
8
i
i
2
ENTER
>
>
ENTER
>
>...>
p.
2
8
2
8
- M
a
n
u
a
l c
o
d
e:
1
1
9
D
W
0
2
11
9
D
W
0
2
v
e
r.
2
.0
2
.0
0
6
/2
0
12 © C
A
M
E
C
a
n
ce
lli A
u
to
m
a
ti
ci
S
.p.
A
. - T
h
e d
a
ta a
n
d i
n
fo
rm
ati
o
n i
n
t
h
is
m
a
n
u
a
l m
ay b
e c
h
a
n
g
e
d at a
n
y time a
n
d wit
h
o
u
t o
b
lig
ati
o
n
o
n
t
h
e p
a
rt
of C
a
me C
a
n
ce
lli A
u
to
m
ati
ci
S
.p.
A
. to n
o
tif
y s
a
id
c
h
a
n
g
e
s.
ENGLISH
F 19 (Automatic closing time):
The automatic closing timer activates at the closing endpoint. The pre-set time is adjustable, and is anyhow conditio-
ned by a possible intervention by the safety devices and is deactivated after a total emergency stop or when the power is cut.
The waiting time can be deactivated or adjusted from 1" to 180".
= 0 = Deactivated (default);
1 = 1 second;
2 = 2=seconds; .................. 180 = 180=seconds.
F 20
(Automatic closing time after partial or pedestrian opening):
leaf automatic closing time after a partial or pedestrian opening command.
The door closes automatically once this time-frame has elapsed and is anyway subject to the trigger of any safety devices and it deactivates after a
«total emergency stop" or due to power outages . The waiting time can be adjusted from 1" to 180”
Note: the automatic closing time (see F 19) should not be deactivated.
1 = 1 second; 2 = 2=seconds; .................. 5 = 5=seconds (default); .................. 180 = 180=seconds.
F 21 (Pre-flashing time):
after an opening or closing command, the flashing light connected on (10-E), flashes for an adjustable time interval before
the manoeuvre begins.
the pre-flashing time can be deactivated or adjusted from 1" to 10".
= 0 = Deactivated (default);
1 = 1 second; 2 = 2=seconds; .................. 10 = 10=seconds.
F 22 (Working time):
motor operation time in when opening or closing.
the working time can be adjusted to between 5" and 120"
5 = 5=(seconds; .................. 120 = 120=(seconds (default).
F 23- (Opening delay time):
after an opening command, the leaf of gearmotor (M1) starts moving after that of gearmotor (M2) and the time is adju-
stable.
the delay time can be deactivated or adjusted from 1" to 10".
= 0 = Deactivated (default);
1 = 1 second;
2 = 2=(seconds .................. 10 = 10=seconds.
F 18 (Light W-E):
output on contact W-E for the light with the following feature:
- movement warning flashing light, flashes while gate is opening and closing.
- outdoor freely placeable light, to enhace lighting in the parking area, set as courtesy light which stays lit for a set time of 180 seconds or as a cycle
light that stays on from the moment the leaf starts opening until it is completely closed (including automatic closing time) .
0 = Flashing light (by default);
1 = Cycle;
2 = Courtesy.