Confi gure either (N.C.) contacts CX or CY , input for EN
12978 compliant safety devices such as photocells.
See CX (F2 Function) or CY(F3 Function) input functions
in:
- C1 «re-open during closing phase», when the gate
leaf is closing, opening the contact triggers the inver-
sion of the direction of movement until the gate leaf is
fully open.
- C2 «re-close during opening phase», when the gate
leaf is opening, if the contact is opened it triggers an
inversion of the direction until gate leaf is fully closed;
- C3 «partial stop», halts moving gate leaves and
causes them to automatically close (if this functions has
been selected);
- C4 «stand-by obstacle», stops the moving gate leaves
causing them to start moving again once obstacle is
removed.
N.B. : if CX and CY contacts are unused they need
to be deactivated during programming.
DIR
photocells
Safety devices
Courtesy or cycle light (contact rated up to:
24V – 25 W max.) – auxiliary connection of
an outdoor lamp that can be freely positio-
ned, for additional lighting of the driveway.
Cycle light: It stays on from the moment the
gate begins opening until it is fully closed
(including the automatic closing time).
Courtesy light: Stays on for a fixed time
period (see function “F25”).
Open gate indicator-light (So-
cket rating: 24 V – 3 W max.). It
turns on when the gate is open.
It turns off when the gate is
closed (see function “F10”).
Flashing light (socket
rating: 24 V DC - 25 W
max.) – It flashes during
opening and closing
phases of leaf.
Warning devices
DELTA-S
photocells
DELTA
photocells