Campbell CR9000X Instruction Manual

Manual is about: Measurement and Control System Overview

Summary of CR9000X

  • Page 1

    Cr9000x measurement and control system overview revision: 3/07 c o p y r i g h t © 1 9 9 5 - 2 0 0 7 c a m p b e l l s c i e n t i f i c , i n c ..

  • Page 3

    Cr9000x overview table of contents overview..................................................................... Ov-1 ov1. Physical description ......................................................................Ov-1 ov1.1 basic system .................................................................

  • Page 4

    Cr9000x overview table of contents ii.

  • Page 5: Overview

    Ov-1 overview the cr9000x is a modular, multi-processor system that provides precision measurement capabilities in a rugged, battery-operated package. The system makes measurements at a rate of up to 100 k samples/second with 16-bit resolution. The cr9000x base system includes cpu, power supply, and...

  • Page 6

    Overview ov-2 measurements: analog output peripheral (ao4) canbus interface peripheral (canbus) csat3 sonic anemometer (csat3) dsp4 display (dsp4) i/o port peripheral (cd16ac) interval timer peripheral (int8) output data to pc card (cardout) serial input/output peripheral (sio4) switch closure measu...

  • Page 7

    Overview ov-3 measurements: battery (voltage and current) control: poweroff 9011 power supply power on off charge(9-18vdc) charge >2.0v 12vout power up made in usa figure ov1-4. Cr9011 ov1.2 measurement modules cr9050 analog input module the cr9050 analog input module has 14 differential or 28 singl...

  • Page 8

    Overview ov-4 cr9051e fault protected 5 v analog input module the number of channels and measurements are the same as for the cr9050 analog input module. Each input channel is fault-protected so as to permit over-voltages between +50 v and –40 v without corruption of measurements on other input chan...

  • Page 9

    Overview ov-5 measurements: voltfilt fftfilt cr9052iepe made in usa open ch 1 short open ch 2 short open ch 3 short open ch 4 short open ch 5 short open ch 6 short figure ov1-8. Cr9052iepe cr9058e isolation module the cr9058e is a 10-channel, differential input isolation module. Each channel has a 2...

  • Page 10

    Overview ov-6 normally thermocouple measurements would be made on the cr9050 analog input module ( ±5 volt) because of its greater resolution, however they can be made on the cr9055 if the ±50 v common mode range is necessary. Thermocouple, differential voltage (tcdiff) thermocouple, single-ended vo...

  • Page 11

    Overview ov-7 measurements: count pulses or frequency (pulsecount) read state of i/o channels (readi/o) write to i/o channels (writei/o) 9070 counter & digital i o 1 2 digital i/o 4 5 7 8 9 10 12 13 15 16 1 2 3 4 5 6 7 8 9 10 11 12 made in usa 3 6 11 14 low level ac switch closurre figure ov1-12. 90...

  • Page 12

    Overview ov-8 pc9000's terminal mode can also be used. Set the comm window to your computer’s comm port and set the baud rate to 115200. With a serial cable hooked between your pc's and cr9000x's rs-232 ports, press the test button to ensure that you have established communications. Close the comm w...

  • Page 13

    Overview ov-9 processing task: measurement task: ov2.3 data tables the cr9000x can store individual measurements or it may use its extensive processing capabilities to calculate averages, maxima, minima, histograms, ffts, etc., on periodic or conditional intervals. Data are stored in tables such as ...

  • Page 14

    Overview ov-10 ov3.2 pc9000 installation to install the pc9000 software: • start microsoft windows 2000, nt, or xp • insert cd • from the program manager, select file menu and choose run • type (disk drive):\setup and press enter , e.G., a:\setup • the setup routine will prompt for disk 2 you may us...

  • Page 15

    Overview ov-11 realtime display & graphing file edit realtime analysis tools collect display windows help program generator open program file . . . Open wiring file . . . Open data table info file . . . Open data file . . . Convert binary to ascii file . . . Print . . . Printer setup . . . Dos shell...

  • Page 16

    Overview ov-12 file edit realtime analysis tools collect display windows help undo ctrl + z date & time select all cut ctrl + x copy ctrl + c paste ctrl + v delete wrap text ctrl + w go to line . . . Find ctrl + f replace ctrl + r colors . . . Fonts . . . Defaults . . . Tile horizontal . . . Tile ve...

  • Page 17

    Overview ov-13 realtime alarms list allows the display of up to 20 fields from a single data table. Two alarm conditions can be created for each field by double clicking the left mouse button while the cursor is held over the field number. After the alarm parameters are set-up, they can be saved to ...

  • Page 18

    Overview ov-14 basic 3-d histogram allows the display of histograms in a real-time 3d format. The 3rd dimension is based on the record number. You can set the number of histogram records that you wish to monitor in a single histogram graph. Rainflow histogram allows the display of rainflow histogram...

  • Page 19: Ov4.  Specifications

    Overview ov-15 windows c9000 setup options size and arrange windows. Select window to bring to the for-ground. Save window setup options to file. Help c9000 help files on-line help for pc9000 software. Ov4. Specifications cr9032 cpu module processors: 180 mhz hitachi sh-4 memory: 128 mbytes of inter...

  • Page 20

    Overview ov-16 cr9050(e) and cr9051e analog input module with rtd input channels per module: 14 differential or 28 single-ended. Range and resolution: max input resolution input sample range (1 a/d count) noise rates (mv) (µv) (µv rms) (khz) ±5000 158.0 105 100 ±1000 32.0 35 100 ±200 6.3 7 50 ±50 1....

  • Page 21: Cr9052Dc Specifications

    Overview ov-17 operating temperature range is -40° to +70°c (specifications valid over this range unless otherwise specified). Non-condensing environment required. To maintain specifications, yearly recalibrations are recommended. Inputs number of differential input channels: 6 programmable anti-ali...

  • Page 22: Cr9052Dc Specifications

    Overview ov-18 c opyright © 2000 c am pbell scientific, inc. Printed april 2001 fft spectrum analyzer fourier transforms applied to anti-aliased inputs described above number of channels: 6 time series sample rates: programmable from 50 ksamples s -1 to 5 samples s -1 fft length: programmable from 3...

  • Page 23

    This is a blank page..

  • Page 24

    Campbell scientific companies campbell scientific, inc. (csi) 815 west 1800 north logan, utah 84321 united states www.Campbellsci.Com info@campbellsci.Com campbell scientific africa pty. Ltd. (csaf) po box 2450 somerset west 7129 south africa www.Csafrica.Co.Za cleroux@csafrica.Co.Za campbell scient...