Camsat CDS-EasyIP User manual - Connection And Start-Up
Connection and start-up
It is recommended that the first start-up and configuration of the system is done at the
desk at small distances. This can save a lot of valuable time with the configuration of
many different cameras.
Transmitter (IP camera):
•
Set the dipswitch No. 1 in OFF (transmitter mode), set the operating channel
according to a table, set the number of transmitter (if there is more than one
transmitter).
•
Connect IP camera compatible with standard 802.3af using a cable with RJ45 to
PORT-2
•
Connect included power supply 48VPoE to PORT-1
•
connect the second camera by the network cable with RJ45to the LAN input in the
power supply of the transmitter.
WARNING
Due to the common voltage PoE 48V in port 2 connection other than specified in the instructions
can cause damage to the recorder, switch or other IT equipment.
WARNING
The current efficiency of such connections is limited to the performance of the recorder port / PoE
switch and is generally 15.4W. Current consumption of receiver (approximately 8W) gives
approximately 7W power for the camera. Please take this into account when selecting a camera.