Chauvet LED Mushroom User Manual

Other manuals for LED Mushroom: User Manual, Quick Reference Manual

Summary of LED Mushroom

  • Page 1

    3000 n 29 th ct, hollywood, fl 33020 u.S.A. (800) 762-1084 – (954) 929-1115 fax (954) 929-5560 www.Chauvetlighting.Com kinta ™ x user manual snapshot ok on dimmer outdoor ok sound activated dmx512 master/slave 115v/230v switch replaceable fuse user serviceable duty cycle.

  • Page 2: Able Of

    Kinta™ x user manual 2 12/16/2008 2:53 pm t able of c ontents 1. Before you begin ................................................................................................................................ 2 what is included .........................................................................

  • Page 3

    Kinta™ x user manual 3 12/16/2008 2:53 pm unpacking instructions immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspec...

  • Page 4: Ntroduction

    Kinta™ x user manual 4 12/16/2008 2:53 pm 2. I ntroduction features 2-channel dmx-512 led derby effect continuous rotation or back and forth motor control built-in automated programs via master/slave or dmx built-in sound activated programs via master/slave or dmx additional features high-power, 3w ...

  • Page 5

    Kinta™ x user manual 5 12/16/2008 2:53 pm product overview sound sensitivity adjustment dipswitches dmx out dmx in power link out power in hanging/mounting bracket bracket adjustment knob.

  • Page 6: Etup

    Kinta™ x user manual 6 12/16/2008 2:53 pm the fuse is located inside this compartment. Remove using a flat head screwdriver. 4. S etup fuse replacement with a flat head screwdriver wedge the fuse holder out of its housing. Remove the damaged fuse from its holder and replace with exact same type fuse...

  • Page 7

    Kinta™ x user manual 7 12/16/2008 2:53 pm this drawing provides a general illustration of the dmx input/output panel of a lighting fixture. Universal dmx controller continue the link c abl e co nne ct o rs cabling must have a male xlr connector on one end and a female xlr connector on the other end....

  • Page 8

    Kinta™ x user manual 8 12/16/2008 2:53 pm often, the setup for master-slave and standalone operation requires that the first fixture in the chain be initialized for this purpose via either settings in the control panel or dip- switches. Secondarily, the fixtures that follow may also require a slave ...

  • Page 9: Perating

    Kinta™ x user manual 9 12/16/2008 2:53 pm 5. O perating i nstructions operation stand-alone mode (sound-active, auto mode): this mode allows a single unit to run to the beat of the music. 1) set dipswitches position to sound active or auto mode. Mode dipswitches sound active 1-10= off 2) the unit wi...

  • Page 10

    Kinta™ x user manual 10 12/16/2008 2:53 pm s e t t i ng t he st art i ng addre s s this dmx mode enables the use of a universal dmx controller device. Each fixture requires a "start address" from 1 to 512. A fixture requiring one or more channels for control begins to read the data on the channel in...

  • Page 11

    Kinta™ x user manual 11 12/16/2008 2:53 pm resolving address using simple math. Address 233 233 – (128) = 105, turn on dip # 8 105 – (64) = 41, turn on dip # 7 41 – (32) = 9, turn on dip # 6 9 – (8) = 1, turn on dip # 4 1 – (1) = 0, turn on dip # 1 d ipswitch (dmx v alue ) 1 2 3 4 5 6 7 8 9 1 2 4 8 ...

  • Page 12

    Kinta™ x user manual 12 12/16/2008 2:53 pm dm x q ui ck re f e re nce ch art dmx address quick reference chart dip switch position dmx dip switch set #9 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0=off #8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 1=on #7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 x=off or on #6 0 1 0 1 0 1 0 1 0 1...

  • Page 13: Ppendix

    Kinta™ x user manual 13 12/16/2008 2:53 pm 6. A ppendix dmx primer there are 512 channels in a dmx-512 connection. Channels may be assigned in any manner. A fixture capable of receiving dmx 512 will require one or a number of sequential channels. The user must assign a starting address on the fixtur...

  • Page 14

    Kinta™ x user manual 14 12/16/2008 2:53 pm general maintenance to maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust ...

  • Page 15

    Kinta™ x user manual 15 12/16/2008 2:53 pm general troubleshooting symptom solution(s) applies to lights foggers & snow controllers dimmers & chaser auto shut off check fan thermal switch reset beam is very dim or not bright clean optical system or replace lamp check 220/110v switch for proper setti...

  • Page 16

    Kinta™ x user manual 16 12/16/2008 2:53 pm contact us world wide general informationchauvet 3000 north 29 th court hollywood, fl 33020 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084 technical support chauvet 3000 north 29 th court hollywood, fl 33020 voice: 954.929.1115 (press 4) fax:...