D.A.S. Variant 18A User Manual - page 16
4.5 STACKING UNITS ON THE SUBS
The VARIANT 18A units feature integral
rigging hardware which can also be used for stacking
VARIANT 25A units on top of them. The maximum
recommended number of VARIANT 25A units in this
mode is 6. The splay angles available between both
enclosures are 0º, 5º and -5º.
The first step will be to mechanically
connect the first VARIANT 25A unit to the VARIANT
18A enclosure. Four safety pins, which are included in
the box, will be necessary to do so. First rotate the
connecting links (1) on the VARIANT 18A until the
desired angle is achieved and introduce the safety pin
through the hole labeled with the desired splay angle
(2). The three available angles are 0º, 5º and -5º. Look
at the label on the VARIANT 18A box.
0º
5º
-5º
0º
V
ARIANT
25
V
ARIANT
18
AX-V25
2
1
The rest of the boxes will be set up using the
above explained procedure for connecting rods and
safety pins. (See page 12)
3
4
Before attaching the first VARIANT 25A to
the subwoofer unit, the connecting links must be
rotated (3) until the desired splay angle with the next
unit on top is reached. Once the desired angle has
been reached the safety pins will be introduced (4)
into the corresponding hole.
5
6
In order to attach the VARIANT 25A unit to
the subwoofer unit, introduce the connecting (5) links
on the VARIANT 18A into the receptacles on the
VARIANT 25A. Then two safety pins (6) must be
introduced (one per side) to secure one enclosure to
the other.
Manual del usuario/
User´s manual
37
Variant series
In the picture above the safety pin has been
introduced into the 0º labeled hole, while in the picture
below the safety pin has been introduced into the +5º
labeled hole.