D&b Audiotechnik Z5576.050 User Manual

Manual is about: D80 Touring rack assembly 18 RU - NEMA

Summary of Z5576.050

  • Page 1

    D z5576.050 manual 1.1 en.

  • Page 2

    S y m b o l s o n t h e p r o d u c t p l e a s e r e f e r t o t h e i n f o r m a t i o n i n t h e m a n u a l . W a r n i n g ! D a n g e r o u s v o l t a g e ! General information z5576.050 manual version: 1.1 en, 04/2018, d2029.Us .01 copyright © 2018 by d&b audiotechnik gmbh; all rights rese...

  • Page 3

    1. Z5576.050 d80 touring rack assembly 18 ru - nema...................................................................................... 4 1.1. Intended use............................................................................... 4 1.2. Scope of supply............................................

  • Page 4

    1.1. Intended use the d&b z5576.050 d80 touring rack assembly nema is intended for large scale mobile sound reinforcement applications. It is designed as a closed and prewired 18 ru system rack, providing mains power distribution and connector interfaces for 6 x d80 amplifiers. For this purpose, the...

  • Page 5

    1.2. Scope of supply before starting up, please verify the shipment for completeness and proper condition of the items. If there is any sign of obvious damage, do not operate the rack assembly and contact your local dealer from whom you received the rack assembly. Pos. Qty. D&b code description [1] ...

  • Page 6

    2.1. Handling the touring rack is equipped with two sliding doors allowing quick and easy access to the front and rear panels of the devices. 1. Unlock the both door lock mechanisms. 2. Open the door and ... 3. Push the door into its park position. 2.2. Cooling and placement when using the d&b z5576...

  • Page 7

    When combining z5576.050 touring rack assemblies with z3010 d12 touring rack assemblies or any other rack assembly that produces an opposing airflow, observe the following restrictions: ▪ do not stack d12 touring racks or any other rack assemblies with opposing airflow on top of the z5576.050 tourin...

  • Page 8

    Z5577.001 rear panel 3.1. Intended use the z5577.001 mains power distributor is designed and dimensioned to provide and distribute the mains power supply necessary for one z5576.050 touring rack assembly. It is a protective class 1 unit with ip class 20 (not rain-, drip-, or splash-proof!). The z557...

  • Page 9

    3.3. Rear panel 3.3.1. Auxiliary mains outputs on the rear panel, four auxiliary mains outputs (120 v / ~60 hz / 1920 w - powercon ® sockets) are provided. Two of these sockets are used to apply mains supply for the ds10 and the poe injector device. The remaining sockets are intended for the connect...

  • Page 10

    4.1. Intended use the z5578 loudspeaker connector panel acts as a connecting interface providing all output channels of each amplifier on its dedicated nl8 socket (4 channels) and two lka25 connector sockets (12 channels each), which directly integrate into the d&b mc24 multicore system. It is a cla...

  • Page 11

    4.3. 4 ch outputs notice! The 4 ch outputs connectors are only intended as an interface to loudspeaker multicores such as the d&b z5343.Xxx and breakout adapters such as d&b z5347.Xxx. Each of the 4 ch outputs connectors represents the 4 channel output of the respective d80 amplifier. Each connector...

  • Page 12

    12 ch output amp 1/2/3 12 ch output amp 4/5/6 lka25 nl8 amplifier lka25 nl8 amplifier a 1+ amp 1 a 1+ amp 4 b 1– b 1– c 2+ c 2+ d 2– d 2– e 3+ e 3+ f 3– f 3– g 4+ g 4+ h 4– h 4– i 1+ amp 2 i 1+ amp 5 j 1– j 1– k 2+ k 2+ l 2– l 2– m 3+ m 3+ n 3– n 3– o 4+ o 4+ p 4– p 4– q 1+ amp 3 q 1+ amp 6 r 1– r 1...

  • Page 13

    5.1. Ds10 configurations the ds10 in combination with the i/o panel is supplied in a pre- wired configuration. The digital outputs (out 1/2 and out 3/4) are linked to the corresponding input sockets (a2 d1/2 and a4 d3/4) of the i/o panel to feed the digital audio signals to the amplifiers. In additi...

  • Page 14

    5.2. I/o panel for systems not using dante audio, inputs and input links can be directly connected to the i/o panel 5.2.1. Input section the input section represents the input connectors of the first amplifier while the other amplifiers are linked within the rack. The input section allows both analo...

  • Page 15

    Can-bus network can represents the can input of the first amplifier while the other amplifiers are linked within the rack. Can link represents the can output of the last amplifier. Terminate/ link the built-in termination switch allows two settings: 1. Link: in system racks, at the start of and with...

  • Page 16

    Mains power connection and internal mains supply distribution 6. Rack wiring diagrams d&b z5576.050 manual 1.1 en 16.

  • Page 17

    Internal 4 channel output wiring d&b z5576.050 manual 1.1 en 17.

  • Page 18

    Internal audio input and link wiring d&b z5576.050 manual 1.1 en 18.

  • Page 19

    Internal ethernet wiring and poe injection d&b z5576.050 manual 1.1 en 19.

  • Page 20

    Internal can-bus wiring d&b z5576.050 manual 1.1 en 20

  • Page 22

    D2029.Us .01, 04/2018 © d&b audiotechnik gmbh www.Dbaudio.Com.