D&B xA 10A Manual

Summary of xA 10A

  • Page 1

    Xa 10a/10a-d manual 1.2 en.

  • Page 2

    S y m b o l s o n t h e p r o d u c t p l e a s e r e f e r t o t h e i n f o r m a t i o n i n t h e m a n u a l . W a r n i n g ! D a n g e r o u s v o l t a g e ! General information 10a/10a-d manual version: 1.2 en, 02/2016, d2610.En .01 copyright © 2016 by d&b audiotechnik gmbh; all rights rese...

  • Page 3

    1. Safety precautions........................................................... 4 1.1. Information regarding the use of loudspeakers.................... 4 2. 10a/10a-d loudspeaker............................................... 5 2.1. Product description.................................................

  • Page 4

    1.1. Information regarding the use of loudspeakers potential risk of personal injury never stand in the immediate vicinity of loudspeakers driven at a high level. Professional loudspeaker systems are capable of causing a sound pressure level detrimental to human health. Seemingly non-critical sound ...

  • Page 5

    2.1. Product description the 10s, 10a and 10al and their "d versions" are a family of high performance 2-way loudspeakers employing a single 10” driver in a bass-reflex enclosure and different hf sections for a wide range of installed sound applications. All models are lightweight passive designs us...

  • Page 6

    2.2. Connections the cabinets are fitted with a pair of nl4 connectors and a two pole screw terminal block (st). All four pins of both nl4 connectors are wired in parallel. The cabinets use the pin assignments 1+/1–. Pins 2+/2– are designated to active subwoofers. Cabinets with the weather resistant...

  • Page 7

    Nl4 connection with cover plate the two nl4 connector sockets of the cabinet's connector panel are located in a recess to allow the use of the cover plate [1] together with nl4 cable connectors, as shown in the graphic opposite. Note: neutrik nl4fc type connectors must be used for this option. The c...

  • Page 8

    Hfa circuit in hfa mode (high frequency attenuation), the hf response of the system is rolled off. Hfa provides a natural, balanced frequency response when a unit is placed close to listeners in near field or delay use. High frequency attenuation begins gradually at 1 khz, dropping by approximately ...

  • Page 9

    2.4. Dispersion characteristics the following graphs show dispersion angle over frequency of a single cabinet plotted using lines of equal sound pressure (isobars) at –6 db and –12 db. Fig. 8: isobar diagram horizontal 10a vertical setup fig. 9: isobar diagram vertical fig. 10: isobar diagram horizo...

  • Page 10

    Fig. 12: isobar diagram horizontal 10a-d vertical setup fig. 13: isobar diagram vertical fig. 14: isobar diagram horizontal 10a-d horizontal setup, horn rotated fig. 15: isobar diagram vertical altering the hf horn dispersion the hf horn can be rotated through 90°. Tools required: philips screwdrive...

  • Page 11

    2.5. Technical specifications 10a/10a-d system data frequency response (–5 db standard) 60 hz - 18 khz frequency response (–5 db cut mode) 100 hz - 18 khz max. Sound pressure (1 m, free field) with 10d/d6 127 db with 30d/d20/d12 130 db with d80 130 db (splmax peak, pink noise test signal with crest ...

  • Page 12

    3.1. Eu conformity of loudspeakers (ce symbol) this declaration applies to: d&b 10a loudspeaker, z1555 d&b 10a-d loudspeaker, z1556 manufactured by d&b audiotechnik gmbh. All production versions of these types are included, provided they correspond to the original technical version and have not been...

  • Page 14

    D2610.En .01, 02/2016 © d&b audiotechnik gmbh www.Dbaudio.Com.