D-MAX DCC-601DV Manual - page 13
13
☞Note
• To produce better results with A.FLK, do not use it in conjunction with the WDR mode of the BACKLIGHT
menu.
• When the SHUTTER is set to ESC after selecting the Internal Synchronization Type, the picture may
become unstable if the camera faces a bright fluorescent light. Therefore, take care when choosing
the installation position.
• ESC and MANUAL modes are only available together when the lens is set to MANUAL.
• When the SHUTTER is set to MANUAL or A.FLK mode, SENS-UP will be disabled.
● AGC (AUTO GAIN CONTROL):
The higher the gain level, the brighter the screen - but the higher the noise.
- OFF : Deactivates the AGC function.
- LOW : Allows automatic gain control from 0 to 24dB.
- HIGH : Allows automatic gain control from 0 to 42dB.
● SENS-UP :
When it is night or dark, the camera automatically detects the light level
and maintains a clear picture if this mode is activated.
- OFF : Deactivates the SENS-UP function.
- AUTO : Activates the SENS-UP function.
● RETURN :
Select this to save the changes in the EXPOSURE menu and return to the SETUP menu.
☞ Note
• If you press the SET button in ‘AUTO’ mode, You can adjust brightness by increasing or decreasing the
shutter speed. (X2~X256)
• Note that the higher the zoom level, the brighter the screen, but the more likely it is that an after-image will
appear.
• Although Noise, Spots, and Whitish symptoms may occur in SENS-UP operation when the zoom level is
Increased, this is normal.
③ White Balance