Da-lite screen company, inc. 3100 north detroit street post office box 137 warsaw, indiana 46581-0137 phone: 574-267-8101 800-622-3737 fax: 574-267-7804 toll free fax: 877-325-4832 www.Da-lite.Com e-mail: info@da-lite.Com instruction book for advantage® deluxe electrol® the da-lite difference..
Pre-installation 1 case installation 1. Thecaseprovidesmultipleattachmentpointsforbolts,cables,orthreadedrod.Page7showsthreadedrod installed.Thevariableposition-mountingbracketmaybelocatedanywherealongthelengthofthecase.Itis recommendedtokeepthebracketsspacedevenlyenoughtodistributetheweightofthescr...
2 ifyourscreenwasshippedwiththemotorandrolleralreadyinstalledproceedtostep6. 1. Removethescrewfromeachendoftheaccessdoor(frontdoor)andopenthedoor.Seefigure1. 2. Carefullyunpackscreenandrollerassembly.Leavepackingpaperontheroller. 3. Placetherollerassemblyintothecasewiththemotorontheleftside.Thelimit...
3 note: useascrewdriveror5/32"allenwrenchtomakeadjustments. More screen drop 1. Placeoperatingswitchin“down”position. 2. Whenthescreenstops,turnthewhite“down” limitknob(fig.2)one-quarterturncounterclockwise.Testbyraising picturesurfaceapproximatelytwofeet,thenloweragain.Repeatuntildesiredpicturesurf...
Advantage ® deluxe electrol ® instructions for standard control 4 220/240v wiring diagram 120v wiring diagram screen motor black (up) red (up) optional rf or ir remote connector white (common) power input 120vac/60hz door motor down stop up note: electrical connections on left end of case. Aux eye o...
Powerinputandcontrol boardarelocatedonright sideofscreenhousing. Brown (hot) green / yellow (ground) blue (common) power input 240vac/50hz down stop up not used back of front of wall switch wall switch screenmotor doormotor terminal block tx - data out g - ground rx - data in tx - data out g - groun...
Powerinputandcontrol boardarelocatedonright sideofscreenhousing. Brown (hot) green / yellow (ground) blue (common) power input 240vac/50hz not used encoder 5v a b gnd screenmotor doormotor screenanddoormotor,microswitch andtimerrelayarelocatedonleft sideofscreenhousing. Doormicroswitch blue (common)...
7 advantage ® deluxe electrol ® installation 9-1/4" (suggested)3/8" threadedrod(not included)attached tomounting bracket finished ceiling self-trimming flange 7-1/4" 8-3/4" caselength variableposition mountingbrackets 7-1/4" 6-1/8" motorend 6-1/8" electrical junctionbox seedetaila (suggested)3/8" th...
8 troubleshooting symptom ifscreenisnotrespondingproperlyand scb100orscb200controlsareused, contactthefactoryfortroubleshooting assistance. 1. Screenwillnotoperateorwillnotgo “down”. Motordoes not hum. Motor hums. 2. Screenwillnotmove upward. Motordoesnothum. Motorhums. Cause (a) incorrectlinevoltag...
Troubleshooting symptom 3. Doorwillnotopen. 4. Doordoesnotclose. 5. “down”limitswitchincorrect. 6. Noise. Note: screen will operate with a low- pitched hum. 7. Coasting. 8. Rollerdisplacedfrommounting bracket. 9. Fabrichangscrooked. 10. Doorclosesbeforescreenisallthe wayup. 11. Dooropensbutscreendoe...
10
Printed in u.S.A. 88584 rev. 10/09 11 limited one year warranty on da-lite presentation products da-litescreencompany,inc.Warrantsitsproductstotheoriginalpurchaseronly,tobefree fromdefectsinmaterialsandworkmanshipforaperiodofone(1)yearfromthedateof purchasebytheoriginalpurchaserprovidedtheyareproper...