    Da-lite screen company, inc. 3100 north detroit street post office box 137 warsaw, indiana 46581-0137 phone: 574-267-8101 800-622-3737 fax: 574-267-7804 toll free fax: 877-325-4832 www.Da-lite.Com e-mail: info@da-lite.Com instruction book for contour® electrol® the da-lite difference..

  • Page 2: Save These Instructions

    1 important safety instructions when using your video equipment, basic safety precautions should always be followed, including the following: 1. Read and understand all instructions before using. 2. Position the cord so that it will not be tripped over, pulled, or contact hot surfaces. 3. If an exte...

  • Page 3

    2 carefully unpack screen and remove outer wrapping from case. Remove the black tape and rubber bands from the slat bar after the case has been installed. There are three ways to install the contour ® electrol ® : wall mount, ceiling mount, or ceiling hook. Procedures for each method are as follows:...

  • Page 4

    3 electrical installation internal wiring has been completed at the factory. Installer must route power to the wall switch and to the junction box located on the left end of the screen case. Standard installation is for a single 120vac or 240vac wall switch to control the screen. Optional control un...

  • Page 5

    4 screen adjustment for 220v/240v screens with a built-in low voltage control 1. Remove the cover plate from the 3-button wall switch and remove the switch from the junction box. 2. Locate small 3-position switch on back of wall switch. (see figure 11) caution: do not adjust for more drop than what ...

  • Page 6

    5 contour ® electrol ® installation up off down this switch can not be used with lvc. 120v wiring diagram with optional built-in video projector interface 120v wiring diagram for standard wall switch 240v wiring diagram with optional built-in video projector interface spdt switch with center off ac ...

  • Page 7

    6 contour ® electrol ® installation figure 11 low-voltage wall switch optional ir and rf remote control motor blue (common) brown (hot) green ground to case 240vac 50hz 240v wiring diagram with optional built-in low voltage control rj9 up stop down ground–must be connected to building ground rj9 gre...

  • Page 8

    Printed in u.S.A. 88819 rev. 12/09 troubleshooting symptom 1. Screen will not operate. Motor does not hum. 2. Incorrect stopping position in downward direction. 3. Incorrect stopping position in upward direction. 4. Noise. Note: screen will operate with a low pitched hum. 5. Coasting. Cause (a) inco...