MULTI VISION IMAGER INSTALLATION
FIGURE 6
LOW-VOLTAGE WALL SWITCH
OPTIONAL IR AND RF
REMOTE CONTROL
MOTOR
BLUE
(COMMON)
BROWN
(HOT)
GREEN
GROUND TO CASE
240VAC 50HZ
240V WIRING DIAGRAM
RJ9
UP
STOP
DOWN
GROUND–MUST BE
CONNECTED TO
BUILDING GROUND
RJ9
GREEN
FRONT
BACK
UP DN
GND +5V
3-POSITION
SWITCH
RJ9
ILT RJ9 PIN-OUTS
(TAB IS FACING UP)
IR or UP
BLACK
GND COMMON
RED
+5V
GREEN
DN or DATA
WHITE
DRY CONTACTS
SPLITTER
UP
+5V
COM
DN
IMPORTANT NOTE:
The wall switch is REQUIRED to make any limit
switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire
the switch or provide a 4-conductor connection
that is accessible.
FIGURE 5
120V WIRING DIAGRAM
GROUND–MUST BE
CONNECTED TO
BUILDING GROUND
RJ-14 PIN-OUTS
(TAB IS FACING UP)
IMPORTANT NOTE:
The wall switch is REQUIRED to make any limit switch
adjustments, EVEN if a third party control system is
used. Therefore, it is advised to wire the switch or
provide a 3-conductor connection that is accessible.
UP
STOP
DOWN
POWER INPUT 120VAC / 60HZ
GREEN (GROUND)
BLACK (HOT)
WHITE (COMMON)
POWER WIRE
DATA
CABLE
RJ-45 JACK
RJ-45
RECEPTACLE
RJ-22
OUTPUT
RJ-22
JACK
RJ-22
INPUTS
RJ-22
JACK
LED
UP LIMIT
TACTILE
BUTTON
DOWN LIMIT
TACTILE
BUTTON
FRONT OF
WALL SWITCH
BACK OF
WALL SWITCH
RJ-22 PIN-OUTS
(TAB IS FACING UP)
RJ-45 PIN-OUTS
(TAB IS FACING UP)
Standard RJ-22 can be used in place of RJ-14
Supplied RJ-14 cable
BLUE
YELLOW
GREEN
RED
BLACK
WHITE
+12V
BUS (RP DATA)
RQ DATA
+5V
GND
RQ CLOCK
BUS (RP DATA)
RQ DATA
+5V
GND
WHITE
GREEN
RED
BLACK
BLUE
YELLOW
GREEN
RED
BLACK
ORANGE
BROWN
PURPLE
+12V
BUS (RP DATA)
RQ DATA
+5V
GND
RQ CLOCK
MANUAL 1
MANUAL 2
DRY CONTACTS
UP
DOWN
COMMON
BUS
5V
BUS
BUS
COM 5V
BUS
3-conductor 20-24 gauge wire can be used in place of
the supplied RJ-14 cable to connect the wall switch.
Connect the BUS terminals on the wall switch to the
corresponding BUS terminals on the splitter board.