Da-Lite TENSIONED ADVANTAGE ELECTROL Instruction Book

Other manuals for TENSIONED ADVANTAGE ELECTROL: Instruction Book, Instruction Book, Instruction Book

Summary of TENSIONED ADVANTAGE ELECTROL

  • Page 1

    Instruction book for tensioned advantage ® electrol ®.

  • Page 2

    2 tools required for installation 1. Hang case and attach to support structure with bolts. See suggested methods of installation. 2. Tighten bolts until trim flange is flush with ceiling. Note: for proper operation, screen assembly must be level after installation. 3. Remove 2 screws to open junctio...

  • Page 3

    3 follow these steps if your screen and roller assembly was ordered separately from the case. 1. Remove the access door. First, remove the 2 screws from the ends using a #2 phillips screwdriver. Be sure to support the door during this step to avoid injury. Then lift the door slightly and pull away f...

  • Page 4

    4 tensioned advantage ® electrol ® suggested methods of installation 3/8" threaded rod (not supplied) hanger bracket electrical junction box motor end variable position mounting bracket audience side 6 7/16" 6 1/16" 7 3/4" 3/8" threaded rod (not included) attached to mounting bracket self-trimming f...

  • Page 5

    5 1. Remove the cover plate from the 3-button wall switch and remove the switch from the junction box. 2. Locate small 3-position switch on back of wall switch. See figure 5 for 120v screens or figure 8 for 220/240v screens. 3. To adjust the down limit switch, slide the 3-position switch to the down...

  • Page 6

    6 rj-45 receptacle rj-22 output rj-22 inputs up (dry contact) down (dry contact) common (both) bus (bus) 5v (bus) up stop down bus c o m 5 v front of wall switch bus up stop down bus c o m 5v led up limit tactile button down limit tactile button back of wall switch tensioned advantage ® electrol ® i...

  • Page 7

    7 rj-45 receptacle rj-22 output rj-22 inputs up (dry contact) down (dry contact) common (both) bus (bus) 5v (bus) up stop down bus c o m 5 v front of wall switch bus up stop down bus c o m 5v led up limit tactile button down limit tactile button back of wall switch up stop down bus c o m 5v power in...

  • Page 8

    8 240v wiring diagram important note: the wall switch is required to make any limit switch adjustments, even if a third party control system is used. Therefore, it is advised to wire the switch or provide a 4-conductor connection that is accessible. Tensioned advantage ® electrol ® installation for ...

  • Page 9

    9 troubleshooting visit www.Da-lite.Com/products/tutorials.Php to find installation and troubleshooting tutorials. You will also find a link to live chat for interactive support. You can contact us by email at info@da-lite.Com or by phone at 800.622.3737 or 574.267.8101 with any additional troublesh...

  • Page 10

    10

  • Page 11

    11.

  • Page 12

    Limited five year warranty on da-lite tensioned advantage ® electrol ® , advantage ® electrol ® , tensioned large advantage ® electrol ® , large advantage ® electrol ® , tensioned contour ® electrol ® and contour ® electrol ® products only milestone av technologies llc warrants these da-lite branded...