Dacor DHI602 Installation Instructions Manual

Other manuals for DHI602: Planning Manual, Use And Care Manual

Summary of DHI602

  • Page 1

    I nstallation i nstructions m illennia ™ i sland (c eiling m ount ) r ange h oods for use with models: dhi361 dhi421 dhi482 dhi542 dhi602 part no. 101744 rev. B.

  • Page 2

    © 2007 dacor, all rights reserved all specifications are subject to change without notice. Dacor assumes no liability for changes to specifications. T able of c ontents b efore y ou b egin ... Important: installer • :intheinterestofsafetyandtominimize problems,readtheseinstallationinstructions compl...

  • Page 3

    1 i mportant s afety i nstructions important information about safety instructions theimportant safety instructions andwarningsinthese instructionsarenotmeanttocoverallpossibleproblems andconditionsthatcanoccur.Usecommonsenseand cautionwheninstalling,maintainingoroperatingthisorany otherappliance. A...

  • Page 4

    2 i mportant s afety i nstructions warning donot 1. Installoroperatethishoodifithasbeendamaged,dropped,hasdamagedelectricalconduitorwiresoris notworkingproperly.Iftheproductisdamagedwhenreceived,immediatelycontactthedealerorbuilder. Usethisrangehoodonlyforitsintendedpurposeasoutlinedintheuseandcarem...

  • Page 5

    3 i mportant s afety i nstructions warning toreducetheriskofinjurytopersonsintheeventofarangetopgreasefire: 22. Smotherflameswithaclose-fittinglid,cookiesheetormetaltray,thenturnofftheburner.Becareful a. Topreventburns.Iftheflamesdonotgooutimmediately,evacuateandcallthefire department. Neverpickupaf...

  • Page 6

    4 p reparing for i nstallation v erify the p ackage c ontents unpackthepartsboxandverifythatallrequired componentshavebeenprovided.Ifanyitemismissingor damaged,pleasecontactthedealerimmediately.Donot installadamagedorincompleteappliance. Hoodassemblywithfilter(s) chimneyassembly(2piece) mountingbrac...

  • Page 7

    5 p lanning the l ocation carefullycheckthelocationwherethehoodistobe • installed.Thehoodshouldbeplacedforconvenient access.Makecertainthatelectricalpowercanbe providedintheselectedlocation. Installtherangehoodandcookingappliance(s)sothat • theycanberemovedifserviceisrequired. Plantheinstallationsot...

  • Page 8

    6 p lan the d uct w ork i nstallation warning toreducetheriskoffireandtoproperlyexhaust • air,besuretoductairoutsidethehouseorbuilding. Donotventexhaustairintospaceswithinwallsor ceilingsorintoattics,crawlspacesorgarages. Tapeallductjointssecurely • topreventcombustion by-products,smokeorodorsfromen...

  • Page 9

    7 i nstallation i nstructions warning donotinstalltherangehoodunlesstheelectrical • serviceprovidedmeetstherangehoodspecifications. Observeallgoverningcodesandordinancesduring • planningandinstallation.Contactyourlocalbuilding departmentforfurtherinformation. Aqualifiedtechnicianmustcompletetheinsta...

  • Page 10

    8 separatethebottomframeworkpiecefromthetop 6. Frameworkpiece.Thetopframeworkpiecehas5-inch slotsonthethesides.Thebottompiecehasaseriesof holesonthesides. Positionthebottomframeworkpieceontopofthe 7. Hood.Slidethestudsonthetopofthehoodintothe holesonthebottomoftheframeworkpiece.Thecut- outsforthewir...

  • Page 11

    9 determinethe 11. Required framework height .Todeter- minetherequiredframeworkheight: putthetopframeworkpieceoverthebottomframework 12. Piece.Themountingslotsonthetoppiecemustbeup. Usefourmachinescrewstofastenthetoppieceto 13. Thebottompiece.Thetotalheightofthetwopieces togethermustequaltherequired...

  • Page 12

    10 i nstallation i nstructions i nstall the d uct w ork warning donotusescrewstoattachtheductworktothe • hoodexhaustoutlet.Useducttapeonly.Screwsmay preventthedamperflapsonthetopofthehoodfrom opening. Installtheductworksystem.Liftthechimneyup • andreachinsidetheframeworktoaccessthehood exhaust.Attac...

  • Page 13

    11 i nstallation i nstructions f inal e lectrical i nstallation warnings toavoidelectricalshockorfirehazard,makesure • thepowersupplyatthefuseorjunctionboxisturned offbeforeproceedingwithfinalelectricalinstallation. Improperconnectionofthehoodelectricalwiringmay • createanelectricshockorfirehazardan...

  • Page 14

    12 i nstallation i nstructions i nstallation c hecklist warning toensureasafeandproperinstallation,thefollowing • checklistshouldbecompletedbytheinstallerto ensurethatnopartoftheinstallationhasbeen overlooked. Properinstallationistheresponsibilityofthe • homeowner.Theimportanceofproperinstallationof...

  • Page 16

    Dacor ● 1440 bridge gate drive, diamond bar, ca 91765 ● tel: (800) 793-0093 ● fax: (626) 403-3130 ● www.Dacor.Com.