Dacor DHI602 Installation Instructions Manual - page 13
11
i
nsTallaTion
i
nsTruCTions
f
inal
e
lectrical
i
nStallation
WARNINGS
Toavoidelectricalshockorfirehazard,makesure
•
thepowersupplyatthefuseorjunctionboxisturned
offbeforeproceedingwithfinalelectricalinstallation.
Improperconnectionofthehoodelectricalwiringmay
•
createanelectricshockorfirehazardandmayresult
indamagetothehoodselectricalsystem.
Donotgroundthehoodtotheneutral(white)power
•
supplywire.Connectthehoodgroundwiretoa
separate,properlygroundedwireinstalledbya
licensedelectrician.
Connect the house power supply wires to the wires
coming out of the hood junction box, inside the
chimney:
Connectthewhitewirefromthehoodtotheneutral
1.
(white)powersupplywire.
Connecttheblackwirefromthehoodtothehot(black)
2.
powersupplywire.
Connectthegreenandyellowwirefromthehoodto
3.
thehouseground(green)wirefromthejunctionbox.
BLACK TO BLACK
YELLOW/GREEN
TO GREEN
WHITE TO WHITE
f
inal
c
himney
a
SSemBly
IMPORTANT:Becarefulnottopinchtheelectricalwires
whileassemblingthechimney.
Movethechimneyuptowardtheceiling.Lineupthe
1.
holesonthesideofthechimney,abovethevents,with
theholesonthesideofthemountingbracket.
Attachthesidesofthechimneytothebracketusing
2.
twomachinescrews,oneoneachside.
Carefully,slidethebottomportionofthechimneydown
3.
untilitrestsonthetopoftherangehood.
Reinstalltherangehoodfilter(s)beforeoperation.