  • Page 1

    Installation instructions millennia ® island (ceiling mount) range hoods models: dhi361, dhi421, dhi482 and dhi542 part no. 101744 rev. F approved for use with all dacor ® ranges and cooktops. Important: installation of this hood requires a chimney kit, dacor part # dhich..

  • Page 2

    Installation instructions ............................................... 5 verify the package contents ....................................... 5 install mounting bracket .............................................. 6 assemble the hood ..................................................... 6 hang t...

  • Page 3

    1 important information about safety instructions the ■ important safety instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. Alw...

  • Page 4

    2 important safety instructions if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, • personal injury or death. Do not • install or operate this hood if it has been damaged, dropped, has damaged electrical wires or is not work- ing prope...

  • Page 5

    3 dimensions tolerances: ±1/16” (±1.6 mm), -0 unless otherwise stated * 18” 1/4 on models dhi482 and dhi542 important: the minimum installed distance from the hood to the cooking surface must be no less than 30 inches. The minimum specified distance may be higher for the particular range or cooktop ...

  • Page 6

    4 planning the location warning observe all governing codes and ordinances during • planning and installation. Contact your local building department for further information. The range hood is heavy. To prevent personal injury • and property damage caused by the hood coming loose from the ceiling, u...

  • Page 7

    5 calculating the maximum duct run length the maximum straight duct length for the hood is 50 feet. To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from 50 feet. Equivalent lengths piece subtract piece subtract 8” 90° elbow 7 feet 10” 90° el...

  • Page 8

    6 assemble the hood place the hood assembly on a soft surface with the 1. Bottom side down during assembly to avoid damage. Tip the hood up on it’s side and remove the filter(s) to 2. Reduce weight and avoid damage. Inside the exhaust outlet(s) there are metal or plastic 3. Damper flaps. The flaps c...

  • Page 9

    7 separate the bottom framework piece from the top 6. Framework piece. The top frame work piece has 5-inch slots on the sides. The bottom piece has a series of holes on the sides. Position the bottom framework piece on top of the 7. Hood. Slide the studs on the top of the hood into the holes on the ...

  • Page 10

    8 install the duct work warning do not use screws to attach the duct work to the hood exhaust outlet. Use duct tape only. Screws may prevent the damper flaps on the top of the hood from opening. Install the duct work system according to the specifica- tions on pages 4 and 5. Lift the chimney up and ...

  • Page 11

    9 preparing for installation final electrical installation warning to avoid electric shock or fire hazard, prior to con- • necting the electrical wiring to the hood, make sure that power to the hood power supply line is turned off at the circuit breaker panel or fuse box. Improper connection of the ...

  • Page 12

    10 installation instructions verifying proper operation make sure power is switched on at the circuit breaker 1. Panel or fuse box. If the control panel is not lit, remove the filter(s) and 2. Turn on the main power switch located behind the filters on the underside of the hood. Replace the filter(s...

  • Page 13

    11 wiring diagrams please note—the layout on the pc board shown above may vary— however all wires are coded and the connections on the pc board are also coded with the same number/letters. Main power switch transformer external blower connection transformer to blower motor yellow/green light fixture...

  • Page 14

    12 wiring diagrams please note—the layout on the pc board shown above may vary— however all wires are coded and the connections on the pc board are also coded with the same number/letters. Main power switch yellow/green external blower connection transformer transformer to blower motor to blower mot...

  • Page 16

    Dacor●600antonblvd.Suite1000costamesa,ca92626●phone:(800)793-0093●fax:(626)403-3130●www.Dacor.Com.