Cooktop Clearance/Ventilation
This section provides information on cabinet clearances
and ventilation surrounding the cooktop.
Under-Counter Clearance
For proper ventilation, maintain:
• at least 5 3/4” (14.6 cm) clearance from the countertop to
any surface below (incl. upper edges of drawers)
• 1” (2.5 cm) minimum clearance between the vents on the
front of the chassis and the cabinet’s inside wall .
Insufficient ventilation between the cooktop and objects
beneath it may cause a fire hazard.
Under-Cabinet Ventilation
If the cooktop chassis is completely enclosed, provide ven-
tilation of at least 18 square inches into the enclosure.
Overhead Ventilation
To reduce smoke accumulation and the risk of personal
injury, Dacor strongly recommends installing a range hood
above the cooktop.
The hood should cover the cooktop entire surface and proj-
ect at least 5 inches beyond the bottom of any overhead
cabinets.
Miscellaneous Installation
This section contains various conditions you may encounter
during the installation process.
Countertop
Always consult the countertop manufacturer for specific
installation instructions/requirements.
The countertop opening must accept the square corners of
the cooktop.
Fire-Retardant Materials
Some conditions may require installation of flame-retardant
materials, which materials are marked:
UNDERWRITERS LABORATORIES INC.
CLASSIFIED
MINERAL AND FIBER BOARDS.
SURFACE BURNING CHARACTERISTICS
This mark precedes the flame-spread and smoke ratings.
These designations are shown as FHC (Flame Spread)/
(Smoke Developed).
Material with “0” flame-spread rating are flame-retardant.
Local codes may allow other flame-spread ratings.
Installation Specifications