Dacor Epicure ER36D Installation Instructions Manual - page 17
15
L1 terminal
L2 terminal
L1 wire
White wire
L2 wire
Strain relief
Neutral terminal
Jumper link
3 Wire Appliance Cord
Connection -
Where Local Code Permits
L1
Neutral
L2
10-50P Plug
Gas Connection
WARNING
Make sure the gas supply valve is off and that the power to
•
the range is turned off at the circuit breaker or fuse box prior
to connecting the gas line.
Do not apply excessive pressure when tightening gas
•
connections and fittings.
Do not use Teflon tape or plumber’s putty on gas flex line
•
connections.
For LP installations, the LP gas tank must have its own
•
high pressure regulator. This is in addition to the pressure
regulator provided with the range.
The maximum gas supply pressure to the regulator must
•
never exceed 1/2 pound per square inch (p.s.i.) or 3.5kPa.
The range and shut-off valve must be disconnected from the
•
gas supply piping during any pressure testing exceeding 1/2
p.s.i. (3.5 kPa).
The range must be isolated from the gas supply piping by
•
closing the shut-off valve during any pressure testing at or
below 1/2 p.s.i. (3.5 kPa).
Check all gas lines for leaks as instructed to avoid a fire or
•
explosion hazard. Do not use a flame to check for leaks.
NOTE:
The gas pressure regulator is pre-set at the factory for
the type of gas intended for use with the appliance. To verify that
the appliance is compatible with the type of gas available, check
the range rating label (see page 3 for location). Ranges intended
for use with LP gas will have “LP” as a part of the model number.
Consult your dealer if the range is not compatible with the type of
gas supplied.
Before sliding the range into the cabinet:
Make sure the gas supply valve is in the off position and that
1.
power to the range is off.
Connect a flexible gas supply line to the gas shut-off valve
2.
previously installed on the stub out. The gas line needs to be
long enough to allow the range to be pulled out for service.
Remove the gas regulator access cover.
3.
Slide the end of the gas line under the back cover into the
4.
regulator compartment from the bottom.
Connect the gas line to the regulator.
5.
Turn all cooktop control valves to the “OFF” position. Turn on
6.
the gas supply.
Check all lines and
7.
connections for leaks
using a soap and
water solution.
After verifying that
8.
there are no gas
leaks, turn off the
gas supply valve
connected to the
range to the “OFF”
position.
Replace the regulator
9.
access cover.
Installation Instructions
Bare wire
connections
Loop and
spade terminal
connections
Regulator
connection
Back of range
Gas line