Dacor Epicure ESG366 Installation Instructions Manual - page 5
3
Product Dimensions
COOKTOP WIDTH (A)
ESG366
35 7/8” (911 mm)
ESG486
47 7/8” (1216 mm)
Installation Requirements
WARNING
Observe all governing codes and ordinances during
•
planning and installation. Contact your local building
department for further information.
To prevent an electric shock hazard, the power supply
•
must meet the specifications stated below.
The electrical and gas supply data on this page is for refer-
ence only. If the requirements below do not agree with the
product data label, use the data on the product data label.
Electrical Requirements
The electrical installation, including minimum supply
•
wire size and grounding, must be done in accordance
with National Electric Code ANSI/NFPA 70 and local
codes and ordinances. A copy of this standard may be
obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
The correct voltage, frequency and amperage must be
•
supplied to the electrical outlet according to the product
data label located on the bottom of the chassis.
The electrical outlet must be installed by a licensed
•
electrician.
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required
Total Connected Load
120 Vac 60Hz,
15 Amp. (3 wire)
0.25 Amp @ 120 Vac, 60 Hz
Gas Supply Requirements
Check your local building codes for the proper method
•
of installation. In the absence of local codes, this
appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54. The
gas service must be installed by a qualified profes-
sional
Be certain that the cooktop being installed is correct for
•
the gas service being provided (natural gas or LP gas).
Also, if operating the cooktop at an altitude above 5000
ft. (1524 m) make sure it is equipped for high altitude
operation. See the inside cover for more information.
An external manual shut-off valve must be installed
•
between the gas inlet and the cooktop for the purpose
of turning on or shutting off gas to the appliance.
Install the regulator provided with the appliance in the
•
gas line that runs from the gas shut off valve to the
cooktop gas inlet. Use only the regulator provided. The
regulator inlet accommodates a 3/4” supply line and is
also compatible with a 1/2” house gas supply. The gas
inlet to the cooktop is equipped with a 1/2” male NPT
connection and a 1/2” to 3/4” elbow attached.
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Manifold
Pressure
Minimum Gas
Supply Pressure
Natural Gas
4” Water Column 5” Water Column
Propane (LP)
10” Water
Column
11” Water Column
* Maximum gas supply pressure for all models is 1/2 p.s.i.
A
3 1/2” (89 mm)
1 1/16”
(27 mm)
7 3/4”
(197 mm)
Trim:
3/8”
(10 mm)
thick
25 1/2” (648 mm)
1 1/8” (29 mm) cooking surface
height (grate level) above
countertop
*Attach supplied regulator and gas
line from bottom or rear of unit
26 1/2” (673 mm)
27” (686 mm)
Power cord,
36” long
Gas inlet
*
1/2” male
connection
3/4” female
connection, elbow
may be removed
Product tolerances: ±1/16” (±1.6 mm)
unless otherwise noted.
SIDE VIEW