Dacor ILHSF10 Planning Manual - Ilhsf8, Ilhsf10
PLANNING
GUIDE
www.Dacor.com Phone: (800) 793-0093
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
9.6
In-line Blowers
ILHSF8, ILHSF10
Model number
Power requirements*
Blower rating
ILHSF8
120 Vac, 60 Hz.,
3.5 Amp.
600 CFM
**
620.7 CFM
***
ILHSF10
120 Vac, 60 Hz.,
4.5 Amp.
1100 CFM
**
1115.9 CFM
***
* In addition to the hood or raised vent
** Nominal at 0 inches static pressure
*** Actual at 0 inches static pressure
Model number
weight
ILHSF8
22 lbs. (10 kg.)
ILHSF10
31 lbs. (14 kg.)
ELEctrIcAL AccESS KNOcK-OUtS
nOTE:
The above specifications are for reference only. See the
1.
data label on the blower for exact specifications. if the
above specifications vary from the label on the blower,
use the data on the blower label.
install this blower only with approved Dacor hoods/
2.
vents. See the hood/vent installation instructions to
determine suitability.
all models are thermally protected
3.
GRN
L1
BLU
BLK
GND
N1
Knock-out
Knock-out
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
200
400
600
800
1000
1200
ILHSF10 Blower Performance
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
200
400
600
800
ILHSF8 Blower Performance
warning
To avoid the risk of fire due to the unit overheating:
DO nOT
•
install this blower with a hood or raised vent that
has an internal blower.
DO nOT
•
install more than one blower to increase the length
of the duct run. Even small differences between blower air
flow rates can greatly reduce the air draw by the hood or
raised vent.
Document # PG09 - 002
Revised 12/09/09 Page 2/2