Dacor Millennia ETT304-1 Installation Instructions Manual - page 3
2
Verifying the Package Contents
Please contact your dealer immediately if
components are missing.
• Use and care manual
• Mounting Brackets
• Cleaning Creme
• Glass Scraper
• Foam Tape
Power disconnection
wARNINg:
Failure to disconnect power may
result in electrical shock or fire
hazard! If the electric service
provided does not meet the product
specifications, do not proceed with
the installation. Call the selling dealer
or a licensed electrician.
Cooktop data Plate Location
The cooktop data plate specifies the model
number, serial number and the electrical
supply requirements. It is located on the
front of the chassis, below the cooktop.
See diagrams.
Electrical Power Supply
Requirements
It is the owner’s responsibility to ensure
that the electrical connection of this
appliance is performed by a qualified
electrician. The electrical installation,
including minimum supply wire size and
grounding, must be in accordance with
the National Electric code ANSI/NFPA*
(or latest revision) and local codes and
ordinances.
Model No.
Electrical Circuit Required
Total Connected
Load
Minimum Supply wire Size
Line and ground Connections
ETT304-1
240 Vac, 60Hz, 40 Amp.
6.9 kW (29A)
No. 8 AWG
ETT365-2
240 Vac, 60Hz, 40 Amp.
9.1 kW (38A)
MET304
240 Vac, 60Hz, 40 Amp.
6.9 kW (29A)
METB365-1 240 Vac, 60Hz, 50 Amp.
9.6 kW (40A)
For reference only, See the cooktop data plate for exact specifications.
Electrical Supply Requirements
Countertop Preparation
wARNINgS:
1.
To reduce the risk of personal
injury caused by reaching
over a hot appliance, cabinet
storage space located directly
above the cooktop should be
avoided.
2.
do not store combustible
materials or items adversely
affected by heat in cabinet
areas above the appliance.
3.
Failure to provide proper
clearances may result in a fire
hazard!
NOTES:
1.
If cabinet storage space is to
be provided directly above the
cooktop, the risk of personal
injury may be reduced by
installing a ventilating hood
that projects horizontally a
minimum of 5 inches beyond
the face of the cabinets.
2.
Allow a minimum 2-inch
clearance between the bottom
of the cooktop chassis and
any combustible surface,
including the upper edge of
a drawer installed below the
cooktop.
3.
Access to the underside of
the cooktop and the junction
box must be provided for
inspection and service.
6" (152mm) Min.
to combustible
side wall above
the cooktop
(both sides)
2" (51mm) Min.
to combustibles
below chassis
4" (102mm)
Chassis height
28 1/2" (724mm)
2" (51mm)
Data
Plate
21" (533mm)
30 1/8" (765mm)
Vertical
Combustible
Surface
3 1/8"
(79mm)
Rear Wall
2 1/4"
(57mm)
Min.
19 7/8" (505mm)
25" (635mm)
6" (152mm) Min.
to combustible
side wall above
the cooktop
(both sides)
2" (51mm) Min.
to combustibles
below chassis
4" (102mm)
Chassis height
34 1/2" (876mm)
2"
(51mm)
25" (635mm)
21"
(533mm)
36 1/8" (918mm)
Vertical
Combustible
Surface
3 1/8"
(79mm)
Rear Wall
19 7/8" (505mm)
2 1/4"
(57mm)
Min.
Data
Plate
Cutout dimensions for the, ETT304-1, and MET304
(ETT304-1 shown)
Cutout dimensions for the ETT365-2, and METB365-1
(ETT365-2 shown)
*A copy of this standard may be obtained
from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency, and
amperage must be supplied to the
appliance from a separate, grounded,
circuit that is protected by a properly sized
circuit breaker or time delay fuse. Refer
to the data plate located on the bottom of
the chassis, and/or to Table 1 above, for
electrical supply requirements.