Dacor Millennia ETT304-1 Planning Manual - page 2
PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
3.2
30 Inch and 36 Inch Wide,
Millennia
®
Electric Cooktops
Ett304-1, Ett365-2, MEt304 and MEtb365-1
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Document # PG03 - 001
Revised 08/20/09 Page 2/3
When installing model ETT365-2 or METB365-1 and the bottom of the chassis is
to be enclosed wall to wall, you must install Dacor ventilation duct kit ATD323.
Allow a minimum of 6 inches (152 mm) clearance between
the top of the countertop and any combustible surface
below, including the upper edge of a drawer below the
cooktop. Proper under-cabinet clearance is also required
for the cooktop hold down brackets.
6” (152 mm)
Min. clearance
to combustible
surfaces
A
6" (152 mm) Min.
from mounting surface to
combustibles below
cooktop chassis
B
Min. overhang,
both sides
Rear
wall
1" Min.
19 3/4" Min.
(502 mm)
1" (25 mm)
(25 mm)
1" Min.
(25 mm)
UNDEr CoUNtEr CLEArANCE
Model
A - Minimum Under Counter
Clearance (Width)
ETT304-1, MET304
30 1/2” (775 mm)
ETT365-2, METB365-1
36 1/2” (927 mm)
Model
B - Minimum Under Counter
Clearance (Width)
ETT304-1, MET304
28 3/4” (730 mm)
ETT365-2, METB365-1
34 3/4” (883 mm)
CoUNtErtoP CUtoUt (WIthoUt rAIsED vENt)
3/4”
7 3/4” X 4 3/8”ventilationcut-outsinenclosurefloor
1 1/2”
1 1/2”
3/4”
toP vIEW vENtILAtIoN CUtoUt
Cooktop cutout in
top of cabinet