Dacor Preference Renaissance RGC304 Installation Instructions Manual - page 8
6
4 1/4" (108 mm) Min.
from mounting surface to
combustibles below
cooktop chassis
E
F
C
D
Minimum distance to combustible side
wall above countertop (both sides)
F
Vertical
combustible
surface
Rear
wall
1 7/8" Min.
(48 mm)
Installation Specifications
Cutout Dimensions
Stiffener
Cabinet face
Countertop
Floor
3/8” Min. (10 mm) space
behind raised vent
chassis to clear stiffener
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
RGC series cooktop
Stiffener
Cabinet face
Countertop
Floor
5/8” Min. (16 mm) space
behind raised vent
chassis to clear stiffener
5/8” Min. (16 mm)
flat countertop overhang
required behind cutout
RV series raised vent:
Check raised vent
dimensions/specifications
to determine proper fit
RGC series cooktop
Side View - RGC Series Cooktop with
ERV/PRV Series Raised Vent
Side View - RGC Series Cooktop with
RV Series Raised Vent
Countertop Cutout
Dimensions
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
Installation Type
(C) Minimum
(D)
(E)
(F)
RGC304 with no raised vent
2 7/8” (73 mm)
19 3/4” (502 mm)
27 5/8” (701 mm)
7 1/2” (191 mm)
RGC304 with ERV30 or PRV30
3/8” (10 mm)
22 1/2” (572 mm)
RGC304 with RV30
5/8” (16 mm)
22 1/4” (565 mm)
RGC365 with no raised vent
2 7/8” (73 mm)
19 3/4” (502 mm)
33 3/4” (857 mm)
7” (178 mm)
RGC365 with ERV36 or PRV36
3/8” (10 mm)
22 1/2” (572 mm)
RGC365 with RV36
5/8” (16 mm)
22 1/4” (565 mm)